STARTING

Prior to starting, refer to your engine manual for proper starting procedure.

1.In a well ventilated outdoor area add fresh, high quality, unleaded gasoline with a pump octane rating of 86 or higher. Do not overfill. Wipe up spilled fuel before starting the engine. Refer to Engine Owners Manual for correct procedure.

2.Check engine oil level. See Engine Owners Manual for correct procedure. NOTE: There will

be a slight amount of oil in the engine from factory testing.

8.

Start engine. See Engine

 

Owners Manual for correct

 

procedure. NOTE: When engine

 

rope is pulled, pressure starts

 

building in the gun. If the engine

 

does not start after two pulls,

 

pull the gun trigger to relieve this

 

pressure.

9.

Depress trigger on gun to

 

start water flow. NOTE: Stand

 

on a stable surface and grip

 

gun/spray wand firmly with both

 

hands. Expect the gun to kick

 

when triggered.

10.

Release trigger to stop water

 

flow.

11.

Adjust spray for the task being

 

performed by changing quick

3.Verify the filter screen is in water inlet of pump.

NOTE: Cone side faces out.

4.Connect

Filter Screen

connect nozzle. See How To Use

Spray Wand instructions in this

section.

SHUTTING DOWN

1. After each use, if you have

applied chemicals, place chemical

hose into container of clean water

and draw clean water through

water source to pump inlet. NOTE: Water source must provide a minimum of 5 gallons per minute at 20 PSI.

5.Connect high pressure hose to pump outlet.

High

Pressure

Hose

Water

Source

6.If applying a chemical or cleaning solution, see How To Apply Chemicals/Cleaning Solvents instructions in this section.

7.Turn water source on. NOTE: Failure to do so could

cause damage to the pump.

 

chemical injection system to rinse

 

system thoroughly. NOTE: Failure

 

to do so could cause damage to

 

the pump.

2.

Turn engine off. See Engine

 

Owner’s Manual. NOTE: NEVER

 

turn the water off with the engine

 

running.

3.

Turn water source off.

4.

Pull trigger on spray gun to

 

relieve any water pressure in

 

hose or spray gun.

5.

See Storage section in this manual

 

for proper storage procedures.

A09741

12- ENG

Image 12
Contents For Parts, Service, Warranty or other Assistance Please call To learn more about Delta MachinerySafety Guidelines Definitions Consumer Safety InformationImportant Safety Instructions Risk of Explosion or FireRisk of Explosion or Fire Risk to BreathingRisk to Fluid Injection Risk of Chemical Burn Risk of Electrical ShockRisk of Unsafe Operation Risk of Injury from SprayCarton Contents Assembly Instructions To Assemble Quick Connect GrommetsTo Assemble Quick Connect Nozzles Engine Switch Enables and disables ignition system Basic Elements of a Pressure WasherChoke Control Opens and closes carburetor choke valve Pressure Adjustments Pressure Washer TerminologyPressure RegulatorRead and Understand ALL Warnings Before Starting Unit To USE Spray WandNozzle Color Red Yellow White Black UsesHOW to Apply Chemicals and Cleaning Solvents To Apply chemicals Press chemicalHose onto Starting Shutting DownMaintenance Nozzle CleaningEngine Pump HOW to Clean the Water Inlet Filter HOW to Remove the WheelsRemove filter by Re-insert filter into water inletStorage Pressure WasherTrouble Shooting Guide ProblemCausecorrection Problem Cause Correction Warranty