Nilfisk-ALTO 107400337 C Install Crank handle for high pressure hose reel/cord reel, Antiscale

Page 8

NEPTUNE 5 FA

3.3Install Crank handle for high pressure hose reel/cord reel

1.Pull cap of crank in arrow direction.

2.Align tabs on crank with slot in axle.

3.Put crank on axle of high pres- sure hose reel/cord reel.

4.Fix crank by pushing the cap.

3.4Fill up detergent tanks

3.5Fill up tank for Nilfisk- ALTO AntiStone (Anti- Scale)

A

B

1.Fill up detergent tanks (A) and

(B) with prediluted detergent. Capacity see chapter 9.4 Technical Data

1.Fill up Nilfisk-ALTO Anti-Stone (Anti-Scale)/water softener reservoir with the sample bottle provided. Nilfi sk-ALTO AntiStone (Anti-Scale) pre- vents any deposits of scale and acts at the same time as a corrosion inhibitor.

For compatibility reasons, use only the tested Nilfisk-ALTO AntiStone (Anti-Scale) which is available as a six-pack of 1 liter bottles by ordering part number 8466.

3.6Antiscale

The Nilfisk Alto Antiscale dosing

Use the schematic to find

the

system is set by the factory.

right dosage of No Scale/anti

To adjust the water hardness we

stone and water, and add

the

recommend that the inlet water

mixture to the antiscale tank.

is tested accordingly.

 

 

Machine flow L/h

Pump size ml/h

˚dH

˚f

 

˚e

Dosage

 

 

 

 

 

 

 

900

35

0-12

0-21,5

0

- 15

1:1 = 17ml/h

 

 

 

 

 

 

900

35

12-30

21,5 - 53,7

15 - 37,5

Pure = 35ml/h

 

 

 

 

 

 

 

1000

35

0-12

0-21,5

0

- 15

1:1 = 17ml/h

 

 

 

 

 

 

1000

35

12-30

21,5 - 53,7

15 - 37,5

Pure = 35ml/h

 

 

 

 

 

 

 

6

1) Options / model variants

Original instructions

Image 8
Contents Neptune 5 FA Operating Instructions Neptune 5 FA Contents Important safety instructions Symbols used to mark instructionsFor your own safety General Before starting the cleanerOperation LiquidWater connection Maintenance and repair TestingDescription Bypass valveBefore starting the cleaner Transport and assemblyOperating elements Set the brakeMachine flow L/h Pump size ml/h ˚dH Dosage Install Crank handle for high pressure hose reel/cord reelAntiscale Fill up fuel tank Connecting the water supply Connections Connecting the spray lance to the spray gunControl / Operation Electrical connectionWater volume Min Steam operation over 100C 212FUsing cleaning agents Applications and methods Vehicle Task Accessories Method Buildings and Equipment Task Accessories Method After using the cleaner Switching off the cleanerStoring the cleaner LinesMaintenance Checking the pump oil quality Changing the pump oilEmptying the fuel oil TankTroubleshooting Indications on DisplayOther Faults Indication lights on control panelUS only GuaranteeFurther information EU Declaration of Conformity EU Declaration of ConformityTechnical Data NeptuneHead Quarter