Nilfisk-ALTO 107400337 C operating instructions Steam operation over 100C 212F, Water volume Min

Page 11

4.2Switching on the cleaner

4.2.1Cold water operation / Hot water operation (up to 100°C)

NOTE!

The cleaner switches off automatically twenty seconds after the spray gun has been closed. To start the cleaner again, squeeze the trigger and the machine will start automatically.

4.2.2Steam operation (over 100°C (212°F))

Beware of hot water and steam discharge up to 150°C when operating in steam stage.

4.3Pressure regulation (Tornado Lance)

4.4Pressure regulation (VarioPress Gun)1)

For safety reasons, never tie back or wedge open the trigger of the spray gun in open position during

operation. The trigger must be free to close when released, thus interrupting the flow of the water.

NEPTUNE 5 FA

1.Turn the main switch to posi-

tion (cold water).

Control electronics accomplishes a self check.

The Display shows for approx. 1 second „---“.

The motor starts. is ON.

2.Turn the main switch to posi-

tion (hot water).

3.Select temperature.

4.Unlock the spray gun and squeeze trigger.

5.The oil burner will light.

6.Release trigger and lock the spray gun when not in use.

1.Open cabinet (and service door if desired - see chapter 3.6, Step 1+2).

2.Turn the twist grip on the safety control block all the way to the left (counter-clockwise-direction).

3.Turn the main switch to position .

4.Select temperature (over 100°C (212°F)).

For special applications: replace the standard nozzle with the steam spray nozzle (accessory).

1.Turn the twist grip on the spray unit:

High pressure =

clockwise (+) for high pres- sure

Low pressure = counter-clockwise (–) for low pressure.

1.Turn the twist grip on the spray unit:

Water volume

(–)

(+)

min.

max.

1) Options / model variants

9

Original instructions

Image 11
Contents Neptune 5 FA Operating Instructions Neptune 5 FA Contents General Before starting the cleaner Important safety instructionsSymbols used to mark instructions For your own safetyOperation LiquidWater connection Bypass valve Maintenance and repairTesting DescriptionSet the brake Before starting the cleanerTransport and assembly Operating elementsMachine flow L/h Pump size ml/h ˚dH Dosage Install Crank handle for high pressure hose reel/cord reelAntiscale Fill up fuel tank Electrical connection Connecting the water supplyConnections Connecting the spray lance to the spray gun Control / OperationSteam operation over 100C 212F Water volume MinUsing cleaning agents Applications and methods Vehicle Task Accessories Method Buildings and Equipment Task Accessories Method Lines After using the cleanerSwitching off the cleaner Storing the cleanerMaintenance Tank Checking the pump oil qualityChanging the pump oil Emptying the fuel oilIndications on Display TroubleshootingIndication lights on control panel Other FaultsUS only GuaranteeFurther information EU Declaration of Conformity EU Declaration of ConformityNeptune Technical DataHead Quarter