NEPTUNE 5 FA
8.2 Indication lights on control panel
|
|
| Indication light |
| Cause |
| Remedy |
|
|
|
|
|
|
|
|
|
|
| fl ashing | > | see FLO | • | see FLO |
|
|
|
|
|
|
|
|
|
|
| ON | > | Low fuel level | • | Fill fuel tank |
|
|
|
|
|
| Cold water operation possible | |
|
|
|
|
|
|
| |
|
|
|
| > Low Nilfi | • | Fill | |
|
|
|
|
|
| Scale) tank | |
|
|
| fl ashing | > | Service interval: Service due |
| Contact |
|
|
|
| in 20 hours |
|
| |
|
|
|
|
|
|
| |
|
|
| ON | > | Service interval expired |
| Contact |
|
|
|
|
|
|
|
|
|
|
| ON | > | Pump oil low | • | Fill to proper level |
|
|
|
|
|
|
|
8.3 Other Faults
Fault |
| Cause |
| Remedy |
|
|
| ||
not ON | > Power cord not properly | • Check power cord connetction | ||
| connected to power supply |
|
| |
|
|
|
| |
|
|
| • Check fuse (see chapter 9.4 Technical | |
|
|
|
| Data) |
Pressure too low | > High pressure nozzle worn | • | Replace nozzle | |
|
| out |
|
|
| > Pressure regulation set to low | • | Turn the twist grip on safety control | |
|
| pressure |
| |
|
|
| block clockwise (+) | |
|
|
|
| |
|
|
| ||
Machine is running with | > Pump has drawn in air due to | • Close detergent valve. Remove lance | ||
pulsating pressure and |
| detergent tank being empty |
| from gun. Operate spray gun and let |
makes knocking noise |
|
|
| machine run until air in pump is gone |
|
|
|
| and the machine is running normally/ |
|
|
|
| calm again. |
No detergents drawn in | > | Detergent tank empty | • | Fill detergent tank |
| > Dirt in detergent tank | • | Clean detergent tank | |
| > Suction valve at cleaning | • Remove suction valve and clean or | ||
|
| agent inlet soiled |
| replace |
Burner soots | > | fuel contamination |
| Contact |
| > Burner sooted or adjustment |
|
| |
|
| incorrect |
|
|
18 | 1) Options / model variants |
Original instructions