Pentair MT Sizes 500 important safety instructions Gas System

Page 22

Key

Description

Size

Size

Size

Size

Size

Size

Size

Size

Size

No

 

500

600

715

850

1010

1200

1430

1670

1825

 

Gas System

 

 

 

 

 

 

 

 

 

55

Burner Tray, IID, On/Off,

10550601

10550602

10550603

10550604

10550605

10550606

10550607

10550608

10550609

 

Single Sect. Manifold {Nat.}

 

 

 

 

 

 

 

 

 

 

Burner Tray, IID, On/Off,

20097401

20097402

20097403

20097404

20097405

20097406

20097407

20097408

20097409

 

Single Sect. Manifold {LP}

 

 

 

 

 

 

 

 

 

 

Burner Tray, St. Pilot, On/Off,

10526201

10526202

10526203

10526204

10526205

10526206

10526207

10526208

10526209

 

Single Sect. Manifold {Nat.}

 

 

 

 

 

 

 

 

 

 

Burner Tray, St. Pilot, On/Off,

10529601

10529602

10529603

10529604

10529605

10529606

10529607

10529608

10529609

 

Single Sect. Manifold {LP}

 

 

 

 

 

 

 

 

 

56

Gas Manifold Weldment

10525901

10525902

10525903

10525904

10525905

10525906

10525907

10525908

10525909

 

{Single Inlet}

 

 

 

 

 

 

 

 

 

57

Burner, Main

L0052300

L0052300

L0052300

L0052300

L0052300

L0052300

L0052300

L0052300

L0052300

58

Pilot Bracket/Burner Weldment

10529502

10529502

10529502

10529502

10529502

10529502

10529502

10529502

10529502

 

{Honeywell}

 

 

 

 

 

 

 

 

 

59

Pilot Burner {Honeywell}

W0035800

W0035800

W0035800

W0035800

W0035800

W0035800

W0035800

W0035800

W0035800

 

Standing Pilot {Nat.}

 

 

 

 

 

 

 

 

 

 

Pilot Burner {Honeywell}

W0034400

W0034400

W0034400

W0034400

W0034400

W0034400

W0034400

W0034400

W0034400

 

Standing Pilot {LP}

 

 

 

 

 

 

 

 

 

 

Pilot Burner {Honeywell}

W0034300

W0034300

W0034300

W0034300

W0034300

W0034300

W0034300

W0034300

W0034300

 

IID Pilot {Nat.}

 

 

 

 

 

 

 

 

 

 

Pilot Burner {Honeywell}

W2001500

W2001500

W2001500

W2001500

W2001500

W2001500

W2001500

W2001500

W2001500

 

IID Pilot {LP}

 

 

 

 

 

 

 

 

 

60

Orifice, Nat. Gas - 4" W.C.

L0050700

L0050700

L0050700

L0050700

L0050700

L0050700

L0050700

L0050700

L0050700

 

{Sea Level}

(22)

(26)

(30)

(36)

(42)

(50)

(60)

(70)

(76)

 

Orifice, Propane - 9" W.C.

L0032900

L0032900

L0032900

L0032900

L0032900

L0032900

L0032900

L0032900

L0032900

 

{Sea Level}

(22)

(26)

(30)

(36)

(42)

(50)

(60)

(70)

(76)

61

Valve, Manual, Gas {Nat.}

V0004200

V0004200

V0004200

V0004300

V0004300

V0004300

V0004300

V0004300

V0004300

 

Valve, Manual, Gas {LP}

V0004800

V0004800

V0004800

V0004800

V0004200

V0004200

V0004300

V0004300

V0004300

62

Safety Gas Valve, On-Off {Nat.}

V0046600

V0046600

V0046600

V0046600

V0046700

V0046700

V0046700

V0046700

V0046800

 

Safety Gas Valve, On-Off {LP}

V0046600

V0046600

V0046600

V0046600

V0046600

V0046600

V0046700

V0046700

V0046700

63

Valve, Gas, Operating/Reg.

V0051200

V0051200

V0051200

V0051200

V0051300

V0051300

V0051300

V0051400

V0051400

 

On-Off {Nat.}

 

 

 

 

 

 

 

 

 

 

Valve, Gas, Operating/Reg.

V0054800

V0054800

V0054800

V0054800

V0054800

V0054800

V0054900

V0054900

V0054900

 

On-Off {LP}

 

 

 

 

 

 

 

 

 

64

Valve, Pilot, Gas Manual

W0002100

W0002100

W0002100

W0002100

W0002100

W0002100

W0002100

W0002100

W0002100

NOTE: Numbers in ( ) represent quantity required for each size. Quantity is one otherwise.

Page 22

Pentair Water Commercial Pool and Spa

Image 22
Contents MegaThermTM Table of Contents General Information Installation of Indoor Boilers InstallationBoiler Placement Minimum boiler clearances from adjacent surfacesVenting Common Venting System Test Procedure Gas Supply and Piping Installation of Outdoor BoilersMinimum Recommended Air Supply to Boiler Electrical Wiring Gas Piping SizesBoiler Model Minimum Filter Pump Flow Rate General Piping InstructionsBoiler By-Pass Piping Minimum Flow to Supply Heater LoopTemperature Sensor Placement and Installation Automatic ChlorinatorsControls General see Figures 12 OperationInitial Start-Up Safety Shutoff Component Checkout Inlet Temperature and Temperature Rise AdjustmentSpring and Fall Operation Stand-by Service Heater Shut DownTime Clock Operation Winter Operation Complete ShutdownTherapeutic Pools Spas Maintenance Manual Gas ValvesTroubleshooting Main Burner Flame PatternSymptom water dripping in firebox Symptom heater will not firePossible Cause What to Do Key Description Size Parts Description and Order NumbersJacket and Combustion Chamber Components Parts Identification Water System Inlet/Outlet Header, Machined Gas System Electrical Components Electrical Components OptionalTile Assemblies Outdoor Parts Control Box Cover Outdoor Pump Parts Pentair Water Commercial Pool and Spa MegaTherm Commercial Pool Heating Boiler Pentair Water Commercial Pool and Spa MegaTherm Commercial Pool Heating Boiler Trademarks and disclaimers 472643 Rev a 05/22/06