3 Setup

3.6 Wire Your System

3.6.1 Stereo Mode

Typical input and output wiring is shown in Figure 3.6. Turn off the amplifier, and set the Stereo/Mono mode switch on the back to Stereo.

INPUTS: Connect input wiring for both channels.

OUTPUTS: Maintain proper polarity (+/-) on out- put connectors.

Connect Channel 1 positive (+) speaker load to Channel 1 positive terminal of amp; repeat for negative (-). Repeat Channel 2 wiring as for Channel 1.

3.6.2 Bridge-Mono Mode

Typical input and output wiring is shown in Figure 3.6. Turn off the amplifier, and set the Stereo/Mono mode switch on the back to Bridge Mono.

INPUTS: Connect input wiring to Channel 1 only.

OUTPUTS: Connect the speaker across the posi- tive (red) terminals of each channel. Do not use the negative terminals when the amp is being operated in Bridge-Mono mode. The load must be balanced so neither lead is connected to ground.

CAUTION: Connect only balanced equip- ment (meters, switches, etc.) to the Bridge-Mono output. Both sides of the line must be isolated from the input grounds or oscillations may occur.

NOTE: To prevent distortion and low lev- els, the Channel 2 level control should be set fully counter-clockwise when operat- ing the amplifier in Bridge-Mono mode.

NOTE: Crown provides a reference of wiring pin assignments for commonly used connector types in the Crown Amplifier Application Guide (Section 1.21.) available at www.crownaudio.com.

3.6.3 Parallel-Mono Mode

Typical input and output wiring is shown in Figure 3.6. Turn off the amplifier, and set the Ste- reo/Mono mode switch on the back to Parallel Mono. Turn down the Channel 2 level control.

INPUTS: Connect input wiring to Channel 1 only.

OUTPUTS: Connect positive (+) speaker load to amplifier Channel 1 red (+) binding post. Con- nect negative (-) speaker load to amplifier Chan- nel 1 black (-) binding post. Add a 14 gauge (or larger) jumper wire between the red (+) binding posts of both channels 1 and 2.

CAUTION: When the amplifier is wired for Parallel-Mono mode, do not change the rear switch to Stereo or Bridge-Mono. Doing that will result in inefficient opera- tion, high distortion and excessive heat- ing.

NOTE: Crown provides a reference of wiring pin assignments for commonly used connector types in the Crown Amplifier Application Guide (Section 1.21.) available at www.crownaudio.

Figure 3.6 Three System Connection Methods

Operation Manual

page 9

Image 9
Contents Some models may be exported under the name Amcron Micro-Tech 600, 1200 601, 1201102990-8 06/04Important Safety Instructions Output wiringUse only with a cart, stand, bracket, or table Declaration of Conformity Safety StandardCrown International, Inc European Representative’s Name and AddressTable of Contents Welcome How to Use This Manual FeaturesUnpacking Your Amplifier Install Your Amplifier Setup You may also stack amps without using a cabi- net Ensure Proper CoolingShows connector pin assignments for Choose Input Wire ConnectorsOutput Connections Choose Output Wire and Con- nectorsBridge-Mono Mode Wire Your System Stereo ModeInputs Connect input wiring to Channel 1 only Parallel-Mono ModeStartup Procedure Set Ground Lift SwitchSet Input Sensitivity Connect to AC MainsPrecautions OperationDo Not operate the amplifier with the Odep LEDs turning off Enable Indicator Odep Indicators Output Device Emulation ProtectionPower Switch Dust FilterStereo/Mono Modes Switch Rear Panel Facilities Power CordReset Switches Micro-Tech 2400 only Input Sensitivity SwitchAdvanced Features Options Accessories Cooling Fan Options Input Connectors OptionFilter Cleaning Principles of Operation OverviewCircuit Theory Stereo Operation Circuit Block DiagramParallel-Mono Operation Bridge-Mono OperationHigh-voltage power supply fuse or breaker has blown TroubleshootingEnergy reserve for the affected channel is dip- ping Supply and fan are still workingSpecifications 120 VAC, 60 Hz Units, Bridge mono mode120 VAC, 60 Hz Units, Parallel mono mode Dimensions Width, Height, Depth Power Draw at IdleWeight 120VAC, 60-Hz units Net Weight Shippping WeightAC Power Draw Thermal Dissipation AC Power Draw Thermal Dissipation Micro-Tech Series Power Amplifiers 12/01 WarrantyWorldwide Except USA & Canada Visa Crown Factory Service InformationPurchase Order for Crown Dealer Card Number Exp. Date