Pentair Energy Master Read and Follow ALL Instructions General, Location, Installation, Priming

Page 2

INSTRUCTIONS

HOW TO ORDER PARTS

READ AND FOLLOW ALL INSTRUCTIONS

GENERAL:

Our shipping container has been specifically designed to prevent transit damage. However, any indications of damage should be carefully noted on the delivery ticket and a claim filed promptly with the carrier.

LOCATION:

Locate the pump as close as possible to the pool. Provide the necessary space around the pump for future inspection and servicing of the unit. If possible, allow several inches of clearance below the motor to floor to allow easy access to mounting screw. Locate away from pool chemicals to prevent spilling on or near motor.

INSTALLATION:

The pump suction line should not be smaller than the pipe size on the inlet of the pump.

Your pump is made of the finest engineering materials available today. A few simple precautions taken during the initial installation, will insure many long years of trouble-free operation.

The threads of pipe fittings screwed into pump must be sealed with: pipe sealant, Teflon® Tape, R.T.V. or other sealing materials approved for pipe threads.

Tighten the pump fitting only as much as is required to insure a tight connection. DO NOT OVER TIGHTEN.

The piping should be supported independently and not supported by the pump.

The pump motor must be wired for the proper voltage, and rotation, in accordance with the wiring diagram supplied with the motor. All wiring should be done by a licensed electrician in accordance with local codes, be certain that the motor frame is grounded. Use lug on top of motor frame to bond together motor and all metallic parts of pool, spa or hot tub structure and to all electrical equipment, metal conduit, and metal piping within 5 feet of the inside walls of a swimming pool, spa or hot tub, when the motor is installed within 5 feet of the inside walls of the swimming pool, spa or hot tub structure with a solid copper conductor not less than No. 8 A.W.G.

Motor name plate has voltage, phase, ampere draw and other motor information. Terminal cover plate or name plate has wiring connection informa- tion.

The wiring to motor should be kept as short as possible and large enough to carry the necessary current for required length without excessive voltage drop. The following table should be followed to be sure that the proper wire size is selected. Use as a guide only.

TABLE OF A.W.G. WIRE SIZE

FOR

SINGLE-PHASE POOL PUMP MOTORS

 

 

 

WIRE LENGTH

 

 

 

 

 

 

 

 

 

H.P.

 

50 FEET

 

100 FEET

 

 

VOLTS

 

VOLTS

 

115

 

230

115

 

230

1/3

14

 

14

14

 

14

1/2

14

 

14

12

 

14

3/4

12

 

14

12

 

14

1

12

 

14

10

 

14

1 1/2

10

 

14

10

 

14

2

10

 

12

8

 

12

 

 

 

 

 

 

 

3

-

 

12

-

 

12

WARNING - To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.

PRIMING:

Fill the pump pot with water before starting the pump. This may be done by removing clear lid. Pumps are self priming providing the pump pot is filled with water. Should you lose this liquid from the pot accidentally or by draining purposely, it will be necessary to refill it with liquid before starting. High Suction Lifts, require additional time for priming.

OPERATION:

After the pump has been filled with water, and the motor started, allow a few moments for the pump to start pumping water. If flow does not start within four minutes, stop motor and refer to (THE TROUBLE GUIDE). Be sure all suction and discharge valves are open when the pump is running. Operating the pump with a closed valve in the system can cause pump damage.

WINTERIZING:

In areas subject to freezing winter temperatures, protect pump by removing both drain plugs, one from the pump volute and one from the pot. Do Not Replace Plugs, store them in strainer basket for the winter.

An alternate is to remove the pump and motor from plumbing and store them indoors in a warm, dry location.

MAINTENANCE:

The strainer basket in pump should be inspected and cleaned twice each week. The strainer basket is easy to clean. Loosen the knobs and remove the clear lid. Remove the basket and clean. Inspect the Lid “O”-Ring; if damaged, replace. Install the Clear Lid, tightening knobs by hand only. The pump seal requires no lubrication. Refer to motor service center for motors.

WHEN ORDERING PARTS, GIVE

H.P., PUMP SERIAL NO., MODEL NO. & ITEM NO.

TO YOUR LOCAL DEALER

--------------------

H.P., PUMP SERIAL NO. & MODEL NO.

ARE LOCATED ON PUMP

22

1

35-3450

Motor Support (for 5 1/2 Dia. Motor)

21

1

15-4909

Motor Outrigger

20

2

35-4256

Set Screw 1/4” x 20 x 3/8” S.S.

19

4

35-4290

Cap Screw 3/8 - 16 x 1” S.S.

18

8

35-4265

Hex Washer Head Screw 5/16” - 18

17

1

35-4001

3/4 Mechanical Seal

16

1

35-2670

Basket w/Handle - Plastic 700

16

1

35-2656

Basket w/Handle - Plastic 590

15

1

35-2600

Lid O-Ring 700

15

1

35-2602

Lid O-Ring 590

14

1

35-3525

Clear Lid - 700 Plastic

14

1

35-3625

Clear Lid - 590 Plastic

13

2

35-4280

Knob - Pot Plastic

12

1

35-4127

Strainer Pot 700 (Plastic)

12

1

35-4125

Strainer Pot 590 (Plastic)

11

2

154699

Plug-Wing .25” Drain Lgr

10

1

19-2323

O-Ring (Pot to Volute)

9

1

35-3912

Volute - Plastic

8

1

35-2626

O-Ring Volute to Bracket

7

1

35-3220

Impeller RPF 3HP

7

1

35-3050

Impeller RPF 2HP, 21/2HP

7

1

35-3049

Impeller RPF 1 1/2HP, RPA 2HP

7

1

35-3013

Impeller RPF 1HP, 1 1/2HP

7

1

35-3044

Impeller RFP 3/4HP, RPA 1HP

7

1

35-3043

Impeller RFP 1/2HP, RPA 3/4HP

7

1

35-3041

Impeller, RPA 1/2 HP

6

2

15-4445

Hex Nut 3/8 - 16 Cad. Pltd.

5

1

35-4894

Pump Tri Pod Base Plastic

4

1

35-3775

Seal Bracket - Plastic

3

2

35-4294

Screw, Cap 3/8 - 16 x 1 1/4” Cad. Pltd.

2

1

35-3750

Shaft Extension - Bronze

1

 

 

Motor

Item

Qty.

Part No.

NAME OR DESCRIPTION

 

 

LIST OF MATERIAL OR PARTS LIST

WARNING: NEVER WORK ON PUMP WHILE IT IS RUNNING OR POWER IS STILL CONNECTED.

2

7

Image 2
Contents LOW Flow Pump willNot Prime MotorMaintenance InstallationTable of A.W.G. Wire Size For SINGLE-PHASE Pool Pump Motors List of Material or Parts ListOperating Instructions Timer Installation for HI-LO Switching of 2 Speed HydropumpSpecial Instruction for TWO Speed Energy Master Hydropump Impeller Clearance Adjustment

Hydropump, Energy Master specifications

Pentair Energy Master Hydropump is a cutting-edge innovation in the field of water management, designed to efficiently handle the challenges of fluid conveyance and pressure management in various applications. This advanced pumping system is specifically engineered to optimize performance, reduce energy consumption, and provide long-lasting reliability.

One of the standout features of the Energy Master Hydropump is its ability to adapt to the varying demands of different operational contexts. With its intelligent control technology, the pump can automatically adjust its speed and output based on real-time flow requirements. This not only ensures optimal efficiency but also significantly reduces energy costs. The energy-saving capabilities are further enhanced by the use of high-efficiency motors that minimize waste and maximize output.

The Hydropump employs advanced materials in its construction, which contribute to its durability and resistance to wear and corrosion. This makes the pump ideal for use in harsh environments where traditional pumps may fail. Additionally, the hydraulic design of the Energy Master Hydropump minimizes turbulence, leading to quieter operation and reduced vibration, thereby prolonging the lifespan of the equipment.

Ease of installation and maintenance is another key characteristic of the Pentair Energy Master Hydropump. Its user-friendly design allows for straightforward setup, while the modular components facilitate quick and easy servicing. The integration of digital monitoring systems enables real-time diagnostics, allowing for proactive maintenance and reduced downtime.

Versatility is a hallmark of the Energy Master Hydropump, making it suitable for a wide range of applications. Whether in industrial settings, agricultural endeavors, or municipal water systems, this hydropump can meet diverse pumping needs. Furthermore, its scalability means that it can be deployed in small systems or configured for large-scale operations without compromising performance.

In summary, the Pentair Energy Master Hydropump stands out in the market for its efficiency, durability, and versatility. Its intelligent control systems, high-quality materials, and ease of maintenance position it as a superior choice for those seeking reliable water management solutions. With its incorporation of cutting-edge technologies, the Energy Master Hydropump not only fulfills current needs but also sets the stage for future advancements in pumping technology.