Toro TDC-100/200 manual Station Settings

Page 10

Station Settings

Station Settings allows you to set parameters specific to each station.

Use the Up or Down Arrows to navigate through the menus.

Use the Left and Right Arrow Keys to advance to the next entry field on the same menu line.

Use the Input Dial

 

to select values when editing.

 

S01

 

Select the station you want to edit in this field. Choose from

 

 

Station 01 through the controller maximum station count of

 

200.

100%

 

If weather or other condition requires irrigation program

 

 

modification, it can be easily adjusted by changing the percent

 

 

adjustment. Station operation can be reduced to 000% (Off) or

 

 

increased up to 900%. 100% represents standard operation.

Decoder Addr: – Enter the decoder’s 5-digit address code that corresponds to

 

the selected station.

DecSta:

If using a 2 or 4-station decoder, select the decoder station to

 

designate to the selected station.

 

Decoder Station Color Codes

 

RED = Station 1, GREEN = Station 2, ORANGE = Station 3,

 

BLUE = Station 4

Path:

Select the correct wire path (1 or 2). Enter wire path 01 for

 

stations connected to the 1st daughter board and wire path 2

 

for the 2nd daughter board.

S100 100% 1STSTLAWN

Decoder Addr: 38684

Dec Sta: 4 Path: 2

Disable: No

Set Sta as a MV: NO

Assn Sta to MV: 000

Sched today: NONE

Water today: NONE

Is Switch:

NO

Hold

Sta :

NO

Cycles

:

01 times

Edit

Name:

01TE020

 

 

 

 

FlowSens:03StaFlo200 Output Volts: 15

Disable:

Use this function to disable station operation by selecting Yes

 

from the menu. Resume station operation by selecting No from

 

the menu.

Set Sta as a MV: – Use this function to designate the station to operate as a Master valve (up to 6) by selecting Yes.

Suggestion: Assign station number that will not interfere with your programming such as 100 or 200.

Assn Sta to MV: – Use this function to assign a station to run with a specific master valve (Not available if the station is designated as a Master Valve).

Sched Today:

This function will display the total scheduled station runtime for the current day.

Water Today:

This function will display the total station runtime that has occurred for the current day.

Is Switch:

Use this function to assign the selected station to a switch. When the switch (station) is

 

activated, the Master Valve or Pump will not actuate.

Hold Sta:

Use this function to delay operation for this station. Select the hold duration from 01–30 days,

 

Permanent or None. This function is useful when a specific station needs to be deactivated

 

without affecting any of the programs.

Cycles:

(For Future Use)

 

Edit Name:

Use this function to assign a name description to the station. In Golf mode, the naming format is

 

XX-AA-YYY, where XX represents the golf course hole number, AA represents the area

 

description acronym and YYY represents the sprinkler number within the area. By following the

 

naming format, you can easily figure out where and what area the station is watering.

 

Area Description Acronym Listing

 

GR = Greens

DR = Driving Range TE = Tee CL = Club House FW = Fairways

 

LA = Landscape

RF = Rough PG = Putting Green AP = Approaches MS = Misc.

 

In Commercial mode, assign a 10-character name of your choice, such as “shrubs” or

 

“back lawn”.

 

Flow Sens:

(For future use.)

 

Output Volts:

Use this function to select the controller’s output voltage. Select between 15 or 20 volts DC.

 

Important! For proper operation, install compatible DC-latching solenoids only.

10

Image 10
Contents TDC-100/200 User’s Guide Page Index Introduction General EditingTiming Mechanism TDC-100/200Daug hter Board Mother BoardMother Board Components Daughter Board Components Home Key Power-Up Diagnostics TDC-100/200 System Booting Rev D1.21, 04/25/06 Detect200sta, 00sen PD 05/24/06Display Adj System SettingsUnits SensorReset All Defaults Stop to escape Reset All Programs To defaults Stop to escapeReset All Stations To defaults Stop to escape Reset Sta Disables Stop to escapeStation Settings Press the Down Arrow Standard Irrigation Program SettingScheduled Watering To selectWhen finished, the display should read P02 100% Hold None Type StandardGrow In Irrigation Program Setting 0400pmManual M-Manual Sta# 01-12 Simult Press Start to water Manual WateringMulti-Manual Station Activation Directions Manual Syringe Activation Directions Manual Syringe Runtime 02 min Program Press Start to waterManual Start Prog Program Press Start to water Manual Program Activation DirectionsMulti-Manual Starting Stop to cancel Percent AdjustPercent Adjust Global100% Program P01 100% Station S01 100% Syringe Starting Program Stop to cancelResume Prg Press Pause to pause 01 Programs Paused Pause / Resume KeyPause / Resume Function Directions Stop Key Cancelling P01 Stop to escapeStop Function Directions Diagnostics Controller Specifications Fuse & Circuit Breaker SpecificationsElectromagnetic Compatibility