Toro Essential Specifications for Sprinkler Controllers

Page 20

Fuse & Circuit Breaker Specifications

Power Supply:

1.5A On/Off Switch/Circuit Breaker – Main Power Input

3.15A Fuse (Slow-Blow) – Field Output

Mother Board: 3.15A Fuse

Controller Specifications

Line Voltage: 100, 220 or 240 VAC 50/60 Hz, 98 VA

Current Draw (no load): 0.21A @ 100-120 VAC, 60 Hz or 0.10A @ 200-240 VAC, 50 Hz

Current Draw (maximum load): 0.91A @ 100-120 VAC, 60 Hz or 0.45A @ 200-240 VAC, 50 Hz

Current Load: 28 VAC

Maximum Current Available for Load: 3.15A (90 VA)

Maximum Load Per Station: 0.0036A (0.01 VA)

Operating Temperature: -10°C to +60°C (14°F to 140°F)

Storage Temperature: -30°C to +65°C (-22°F to 149°F)

Electromagnetic Compatibility

Radio complies with FCC Part 22 and Part 90 of the FCC Rules

Domestic: This equipment has been tested and found to comply with the limits for a FCC Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. The equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to the radio communications. Operation in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

© 2007 The Toro Company, Irrigation Division • An ISO-9000-Certified Facility

Form Number 373-0379 Rev. C

Image 20
Contents TDC-100/200 User’s Guide Page Index Introduction General EditingTiming Mechanism TDC-100/200Mother Board Mother Board ComponentsDaug hter Board Daughter Board ComponentsPower-Up Diagnostics TDC-100/200 System BootingHome Key Rev D1.21, 04/25/06 Detect200sta, 00sen PD 05/24/06System Settings UnitsDisplay Adj SensorReset All Programs To defaults Stop to escape Reset All Stations To defaults Stop to escapeReset All Defaults Stop to escape Reset Sta Disables Stop to escapeStation Settings Standard Irrigation Program Setting Scheduled WateringPress the Down Arrow To selectWhen finished, the display should read P02 100% Hold None Type StandardGrow In Irrigation Program Setting 0400pmMulti-Manual Station Activation Directions Manual WateringManual M-Manual Sta# 01-12 Simult Press Start to water Manual Syringe Runtime 02 min Program Press Start to water Manual Start Prog Program Press Start to waterManual Syringe Activation Directions Manual Program Activation DirectionsPercent Adjust Percent Adjust Global100% Program P01 100% Station S01 100%Multi-Manual Starting Stop to cancel Syringe Starting Program Stop to cancel Pause / Resume Function Directions Pause / Resume Key Resume Prg Press Pause to pause 01 Programs Paused Stop Function Directions Cancelling P01 Stop to escapeStop Key Diagnostics Electromagnetic Compatibility Fuse & Circuit Breaker SpecificationsController Specifications