Scheduled Watering

The TDC-100/200 features 10 fully-independent resident programs. With two types of programs to select from, you can further custom fit your irrigation programs to any landscape.

Standard Irrigation Program will activate a station or group of stations with six start times on a daily basis. Each station will water for the duration specified in hours, minutes and seconds. Percent adjust and maximum number of simultaneous activate stations per program can be specified in this program.

Grow-In Irrigation Program will activate a station or group of stations for the length of their runtime. The program will repeat the cycle after the specified delay time expires and will repeat continuously between the set Start and End times. Percent adjust and the simultaneous activate stations can be specified in this program.

To utilize these programs automatically or manually, each program must be configured.

Standard Irrigation Program Setting:

Standard Irrigation Program example: Create Program 02 with stations 6–10 running 15 minutes each and stations 15–20 running 10 minutes each with no percent adjustments. Set the start time at 6:30 am with five maximum simultaneous active station.

1. Press the Scheduled Watering Key . The cursor is initially located at the program selection field. Use the

Input Dial

 

to select the program (P01–P10) you want to create or modify. For this example, select 2.

 

2. Press the Right Arrow Key to standard to the Percent Adjust field. Normally this setting will be 100%

unless weather or other condition suggest that less or more irrigation is needed. Use the Input Dial

to adjust the setting. For this example, no adjustment is needed.

3.Press the Down Arrow to advance the cursor to the Hold: field. Use this function to suspend program operation. Select from None, Today, 0230days or Permanent. For this example, select None.

4. Press the Down Arrow

to advance the cursor to the Type: field. Use the Input Dial

 

to adjust

 

the setting. For this example, set the Type to Standard.

5. Press the Down Arrow

to advance the cursor to the Days: field. Use the Input Dial

 

to select

 

the program activation interval from 01–30 days. Select 01 for everyday, 02 for every other day, 03 for every

third day and so on. The example does not call for a set interval. Leave the Days: setting to SMTWTFS...

6. Press the Down Arrow

to advance the cursor to the Set: field. Use the Input Dial

 

to select

 

from any of the preset intervals (All, Alternate days, Weekdays only, Weekends only, None or User set). To

create your own program activation interval, select Set:. Use the Right Arrow Key

to select the day of the

week you want to irrigate and use the Input Dial

 

to activate (X) or deactivate (blank) the selection.

 

For this example, activate M (monday), W (wednesday) and F (friday) only. MWF of the 1st and 2nd week

should have an X mark under while the rest are blank.

7. Press the Down Arrow to advance the cursor to the Start: field. The first entry field will indicate the start

time number. Each program can have a maximum of 24 start times. Use the Input Dial

 

to choose

 

the start time being created or modified. Press the Right Arrow Key to advance to the time entry field.

Use the Input Dial

 

to select the start time in hours and minutes ( HH:MM). Repeat Step 7 for

 

additional start times. For this example, set start time 01 to 05:45am.

(Continued to the next page)

11

Image 11
Contents TDC-100/200 User’s Guide Page Index General Editing IntroductionTDC-100/200 Timing MechanismDaughter Board Components Mother BoardMother Board Components Daug hter BoardRev D1.21, 04/25/06 Detect200sta, 00sen PD 05/24/06 Power-Up DiagnosticsTDC-100/200 System Booting Home Key Sensor System Settings Units Display AdjReset Sta Disables Stop to escape Reset All Programs To defaults Stop to escapeReset All Stations To defaults Stop to escape Reset All Defaults Stop to escapeStation Settings To select Standard Irrigation Program SettingScheduled Watering Press the Down ArrowP02 100% Hold None Type Standard When finished, the display should read0400pm Grow In Irrigation Program SettingMulti-Manual Station Activation Directions Manual WateringManual M-Manual Sta# 01-12 Simult Press Start to water Manual Program Activation Directions Manual Syringe Runtime 02 min Program Press Start to waterManual Start Prog Program Press Start to water Manual Syringe Activation DirectionsSyringe Starting Program Stop to cancel Percent AdjustPercent Adjust Global100% Program P01 100% Station S01 100% Multi-Manual Starting Stop to cancelPause / Resume Function Directions Pause / Resume KeyResume Prg Press Pause to pause 01 Programs Paused Stop Function Directions Cancelling P01 Stop to escapeStop Key Diagnostics Electromagnetic Compatibility Fuse & Circuit Breaker SpecificationsController Specifications