E. Cutting the Feed Hose - (cont.)
3.Lay the telepole next to the clear (soft) hose. If the clear (soft) hose is longer than the mark on the telepole, cut the excess from the end attached to the white (hard) hose. Do not cut off the float. Leave the first float in position next to the
| Telepole / Clear (Soft) Hose | |
White (Hard) Hoses | Swivel | Water Level |
|
| |
| Cut and Remove the | Cut Clear (Soft) Hose Equal to |
| Excess Hose Length | |
| the Deepest Pool Water Level | |
|
|
4.Attach feed hose to the wall fitting and attach to the pool wall. Hold the end of the 30 in. clear (soft) hose and walk the perimeter of the pool keeping the hose straight (do not stretch hose) to find the farthest point of the pool from the wall fitting.
5.Measure the excess length between the farthest point of the pool from Wall Fitting and the end of 30 in. clear (soft) hose.
6.Half of this measured length to be cut equally from the 10 ft. long hoses next to the Marked Swivel. (Example: Half of 6 ft. = 3 ft. each). If you are cutting more than 2 ft. off the hoses, remove the floats next to the Marked Swivel from both hoses. See Figures on page 4.
7.
FEED | MENDER | BARB ON SWIVEL | |
OR LEGEND | |||
HOSE | NUT | ||
SMALL END | |||
|
| ||
|
| OF MENDER | |
|
| NUT AWAY | |
|
| FROM HOSE |
STEP 1
PUSH HOSE OVER BARB
STEP 2
PUSH MENDER NUT TOWARD HOSE AND ROTATE
CLOCKWISE BY HAND UNTIL TIGHT
STEP 3
5