Pentair Side Pool Cleaner installation manual Checking Wheel RPM

Page 12

3. Checking Wheel RPM

To determine whether the Legend® Platinum is receiving the proper water pressure, turn off the booster pump, pool pump and carefully remove the Legend® Platinum from the pool.

Mark the front drive Tire/Wheel with a marker, or use the Logo located on the side of tire as a marker to count the rotations of the wheel per minute.

Have someone turn on pool pump and then booster pump while you place the Legend® Platinum in the pool just beneath the water surface. (Be sure to hold onto the Sweep Hose to avoid getting wet).

Count the rotations of the marked wheel for exactly one minute. (Be sure the Back-Up Valve isn't cycling at this time). The rotations will give you the Revolutions Per Minute, (RPM).

For proper performance, the Legend® Platinum operates between 28-32 RPM. If the RPM is below 28 then call your local Pool Professional or contact our Technical Support Department at 1-800-831-7133.

If the RPM is more than 32, at the Wall Fitting unscrew the Pressure Valve slowly until the RPM falls between 28-32.

If you have any additional questions, please contact our Technical Support Department @ 1-800-831-7133.

8

LEGEND® PLATINUM INSTALLATION MANUAL

Image 12
Contents Installation Guide Customer Service Web siteLL105PMTGG / LL105PMTWW LL105PMTRW / LL105PMTYW Important InformationTable of Contents Thank You for Choosing the Legend Platinum Pool Cleaner What to Expect from the Legend PlatinumBooster Pump Installation Pool ConnectionsInstalling the Twist Lock Pressure Relief Valve Wall Fitting Cutting the Feed HoseExample of Hose Assembly Before Cutting to Length Step Feed Hose Fine Tuning the Legend Platinum Thrust Jet AdjustmentSweep Hose Adjustment Checking OperationChecking Wheel RPM Connecting/Disconnecting the Legend Platinum Periodic MaintenanceWall Fitting Screen Accessories Back Washing the Pool FilterStorage and Winterizing IV. Troubleshooting and Performance Tips Problems & Solutions Diagram # Description Quantity Diagram # First Second Hose 31/06 P/N Yyplatinstall REV. C