Crown Audio MA-2402 operation manual AC Power Draw and Thermal Dissipation

Page 25

MA 2402 Power Amplifier

9 AC Power Draw and Thermal Dissipation

This section provides detailed information about the amount of power and current drawn from the AC mains by the Macro-Tech 2402 amplifier and the amount of heat produced under various conditions. The calcula- tions presented here are intended to provide a realistic and reliable depiction of the amplifier. The following assumptions or approximations were made:

The amplifier’s available channels are loaded, and full power is being delivered.

Amplifier efficiency at standard 1 kHz power is estimated to be 65%.

Quiescent power draw is 90 watts (an almost negligible amount for full-power calculations).

Quiescent thermal dissipation equals 105btu/hr at 90 watts.

The estimated duty cycles take into account the typical crest factor for each type of source material.

Duty cycle of pink noise is 50%.

Duty cycle of highly compressed rock ‘n’ roll midrange is 40%.

Duty cycle of rock ‘n’ roll is 30%.

Duty cycle of background music is 20%.

Duty cycle of continuous speech is 10%.

Duty cycle of infrequent, short duration paging is 1%.

Here are the equations used to calculate the data presented in Figure 9.1:

 

 

Total output power with all

x

Duty

 

AC Mains Power

=

channels driven (watts)

 

Cycle

+

Quiescent Power

Draw (watts)

 

Amplifier Efficiency (.65)

 

 

Draw (watts)

 

 

 

 

 

The quiescent power draw of 90 watts is a maximum value and includes power drawn by the fan. The following equation converts power draw in watts to current draw in amperes:

 

 

 

 

 

AC Mains Power

 

 

 

 

Current Draw

=

 

Draw (watts)

 

 

 

 

 

 

(amperes)

AC Mains

x

 

Power

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

Factor (.83)

 

 

The power factor of 0.83 is needed to compensate for the difference in

 

phase between the AC mains voltage and current. The following equa-

 

tion is used to calculate thermal dissipation:

 

 

 

 

 

 

Thermal

 

Total output power with all

x Duty

x .35

Quiescent Power

 

 

 

channels driven (watts)

Cycle

 

 

 

 

Dissipation =

(

 

 

 

 

 

 

+

Draw (watts)

)

x 3.415

(btu/hr)

Amplifier Efficiency (.65)

 

 

 

 

 

 

 

 

 

The constant 0.35 is inefficiency (1.00–0.65) and the

factor 3.415 converts watts to btu/hr. Thermal dissipation in btu is divided by the constant 3.968 to get kcal. If you plan to measure output power under real-world conditions, the following equation may also be helpful:

Thermal

 

 

Total measured output power x .35

Quiescent Power

 

 

Dissipation =

 

 

from all channels (watts)

x

3.415

 

 

 

+

Draw (watts)

 

(btu/hr)

(

 

)

 

 

Amplifier Efficiency (.65)

 

 

 

Operation Manual

page 25

Image 25
Contents Some models may be exported under the name Amcron Macro-TechImportantes Instructions de Sécurité Important Safety InstructionsCrown Audio, Inc Safety StandardTCF Technical Certificate No P4300CRI1.IWS Competent Body’s Name and AddressTable of Contents Features How to Use This ManualWelcome Unpack Your Amplifier Install Your Amplifier SetupYou may also stack amps without using a cabinet 48.3 cmChoose Output Wire and Con- nectors Choose Input Wire ConnectorsStereo Mode Wire Your SystemSee .6. Set the back panel stereo/mono switch to Stereo Bridge-Mono ModeParallel-Mono Mode Precautions Startup ProcedureOperation Set Input SensitivitySignal/IOC Indicators Front Panel Controls and IndicatorsOdep Indicators Enable IndicatorStereo/Mono Switch Back Panel Controls, Indicators and Connec Tors Power CordReset Switches Input Sensitivity Switch not shownIndicators IndicatorsStandby Mode Advanced Features OptionsProtection Systems OdepHere are some of its many features Advanced FeaturesFuses and Circuit Breakers PIP2 Adapter Connection Options PIP and PIP2 ModulesLevel Control Shaft Lock Cooling Fan OptionsTroubleshooting Theory of Operation Please refer to the block diagram in FigureOverview Circuit TheoryParallel-Mono Operation Bridge-Mono Operation120 VAC, 60 Hz Units, Bridge mono mode Specifications120 VAC, 60 Hz Units, Parallel mono mode Dimensions Width Power Draw at IdleWeight Net Weight Shipping WeightMacro-Tech 2402 Maximum Power Matrix Maximum Power NotesMacro-Tech 2402 Minimum Power Matrix Minimum Power NotesConstant 0.35 is inefficiency 1.00-0.65 AC Power Draw and Thermal DissipationAC Power Draw Thermal Dissipation Service United States & Canada Warranty12/01 Reason for failure, except as excluded in this WarrantyMA 2402 Power Amplifier Fax Crown Audio, IncMishawaka Rd Elkhart This page Intentionally Left Blank ‰ Personal/Consumer ‰ Business/Corporate ModelMA 2402 Power Amplifier MA 2402 Power Amplifier