Desa Rgh3000, Rgh3000pr, Rgh5500a, Rgh5500aie, Rgh7500aie, And Rgh11000aie Engine OIL, Fuel

Page 7

OWNER’S MANUAL

GENERATOR

FEATURES

Continued

2. If the GFCI receptacle tests okay, re-

store power by pushing the RESET

button back in. The test lamp should

work at this time. IMPORTANT: You

must press the RESET button firmly

and fully. It should lock into place. If

the GFCI does not lock into place, do

RECEPTACLE CIRCUIT BREAKER

The circuit breakers protect the receptacles and alternator. Overloading generator will trip circuit breaker. A short circuit in item being powered will also trip breaker. If this occurs, unplug electrical load from recep- tacle. Let circuit breaker cool down. Push circuit breaker button to reset.

Electric motors need higher starting current. They require up to three-times their rated

Oil

Oil Level

At Top Of

Filler Neck

Dipstick

not use receptacle. Contact a qualified

electrician for repairs.

RESET

TEST

Figure 4 - GFCI Receptacle

ENGINE CIRCUIT BREAKER

(Models RGH5500AIE, RGH7500AIE, AND RGH11000AIE)

This circuit breaker, or fuse, protects the battery charging circuit. A short circuit will trip the circuit breaker. The circuit breaker will also trip if you install battery wrong. Push circuit breaker button to reset. On Model RGH11000AIE, the fuse is located inside of the Keyswitch box.

 

ON

 

OFF START

Engine Circuit

ENGINE SW

CIRCUIT

Breaker Button

BREAKER

 

ON/push OFF

Figure 5 - Engine Circuit Breaker

wattage to start. The starting current needed may be too high. This can cause nuisance circuit breaker tripping. To help prevent this, start electric motors first. Connect ad- ditional items to generator after starting motors. If this continues to happen, reduce the total generator load.

Normal 20

Tripped 20

Figure 6 - Receptacle Circuit Breaker Button

Note: High ambient temperature will cause nuisance tripping.

ENGINE OIL

We ship the generator without oil in the engine crankcase. You must add oil before starting engine. See engine owner’s manual for specific oil type.

CHECKING OIL LEVEL AND ADDING OIL

Follow steps below to check oil level. Make sure engine is level and stopped.

1.Remove dipstick (see Figure 7). Wipe dipstick clean.

2.Insert dipstick into oil filler neck. Do not screw it in. Oil level should be at top of filler neck. Oil should cover most of dipstick. For Model RGH11000AIE only, the oil should be between the two dots on dipstick.

3.If level is low, fill to top of oil filler neck (see Figure 7). For Model RGH11000AIE only, fill to top dot on dipstick. Only use oil recommended in engine owner’s manual.

Note: If oil level is too low, oil alert system will shutdown engine and prevent engine from restarting.

Figure 7 - Checking Oil Level (Model RGH5500A Shown)

FUEL

WARNING: Gasoline presents a hazard of fire or explosion. Gasoline is flammable. Its vapor is explosive.

Keep fuel out of children’s reach.

Refuel generator in a well- vented area. Do not fill fuel tank in the dark. Do not refuel while engine is running. Unhook all electrical loads and shut off engine before refueling.

Do not overfill fuel tank. Al- ways allow room for fuel to expand. If you overfill tank, fuel can overflow onto hot engine. This can cause fire or explo- sion. After refueling, tightly close fuel tank cap.

Do not spill fuel. Fuel or fuel vapor may ignite. If fuel spills, make sure area is dry before starting engine.

Never smoke in refueling area. Never allow open flames or sparks in area.

Store fuel in approved con- tainer. Store fuel in a well- vented area free of open flames or sparks.

Use clean, fresh, unleaded gasoline. Use gasoline with octane rating of 86 or higher. Service station gasoline pumps should dis- play the octane rating. Using gasoline with lower octane level could damage engine. Avoid getting dirt, dust, or water in fuel tank. Do not mix oil with gasoline.

See engine owner’s manual for more information.

106815

7

Image 7
Contents Portable Gasoline Generators OWNER’S Operation and Installation ManualPortable Gasoline Generators Safety InformationIf engine speed changes greatly Product IdentificationVentilation High and LOW Temperature OperationGeneral Information UnpackingModel SpecificationsRGH3000PR RGH5500AIE RGH7500AIE RGH11000AIE AUTO-IDLE System Generator FeaturesFull Power Selector Switch OIL Alert SystemEngine Circuit Breaker Engine OILFuel Receptacle Circuit BreakerInstalling Battery Cables to Engine BatteryHandles TOP Cover Generator Grounding Mounting Battery to GeneratorRecommended Minimum Wire Gauges AWG for Extension Cords Extension CordsDetermining Electrical Load for Generator Standby Installation to Home or BuildingChart 1 Typical Electric Appliance Wattages ChartGeneral Information Power Cord and Plug RequirementsUsing Receptacle OperationStarting PrestartAUTO-IDLE Operation Adjusting the Idle SpeedHigh Altitude Operation Adding Electrical Loads Disconnecting Electric LoadsStopping Engine Troubleshooting Maintenance and RepairsStorage Wiring Diagrams Electrical Component SpecificationsWiring Diagram, Model RGH5500AIE Wiring Diagram, Model RGH11000AIE Servicing the Engine Technical ServiceAccessories Replacement PartsParts Available not Shown Illustrated Parts ListFor Models RGH3000 RGH3000PR Alternator Assembly KEY Part Number Description QTYRGH5500AIE RGH7500AIE Description QTY Alternator AssemblyFor Models RGH5500A RGH5500AIE, Part Number for Model KEYKEY Part Description Number QTY For Model RGH11000AIE Alternator AssemblyWP-5C For Models RGH3000 RGH3000PR Roll CagePortable Gasoline Generators Only on RGH5500AIE electric start models Tank and Roll Cage WP-4C For Model RGH11000AIE Fuel Tank and Roll CageFor Models RGH5500A RGH5500AIE, RGH7500AIE Control Panel Under Replacement Parts onFor Model RGH11000AIE Control Panel Listed under Replacement Parts onFor Solenoid and Control Board Assemblies and Mounting For Solenoid and Control Board Assemblies and Mounting International Keep this Warranty

Rgh3000, Rgh3000pr, Rgh5500a, Rgh5500aie, Rgh7500aie, And Rgh11000aie specifications

Desa is recognized for its innovative heating technology products, and among its offerings are the Rgh series, which includes the Rgh3000, Rgh3000pr, Rgh5500a, Rgh5500aie, Rgh7500aie, and Rgh11000aie. These models embody the latest advancements in performance and energy efficiency, catering to a variety of heating needs in both residential and commercial applications.

The Rgh3000 and Rgh3000pr are compact yet powerful solutions designed for smaller spaces. They are equipped with high-efficiency heating elements that allow for quick warmth distribution, making them ideal for personal rooms or as supplemental heating sources. The Rgh3000pr variant includes programmable features, enabling users to set specific heating schedules, optimizing energy use and offering cost savings over time.

For larger areas, the Rgh5500a and Rgh5500aie models provide enhanced heating capacity without sacrificing efficiency. The Rgh5500aie features integrated smart technology, allowing users to control the heater remotely via smartphone applications. This model also boasts increased insulation and improved heat retention capabilities, ensuring that warmth is maintained longer while reducing energy consumption.

Moving up the line, the Rgh7500aie offers even greater versatility with its multi-zone heating options. Users can create tailored heating environments based on individual room requirements, maximizing comfort and minimizing energy wastage. The Rgh7500aie model also incorporates advanced air filtration, improving indoor air quality alongside heating functionality.

The Rgh11000aie stands at the pinnacle of this series, providing unparalleled heating power suited for large commercial spaces or expansive homes. Its energy-efficient design is complemented by cutting-edge smart technology, allowing for real-time temperature monitoring and adjustments. This model is also equipped with advanced safety features, including automatic shut-off mechanisms, ensuring peace of mind during operation.

All these models share a commitment to sustainability, utilizing Eco-friendly materials and energy-efficient technologies. Their sleek designs seamlessly integrate into various decor styles, making them not only functional but aesthetic additions to any environment. With options catering to differing heating needs, Desa’s Rgh series stands out in delivering modern heating solutions that prioritize user convenience, efficiency, and environmental responsibility.