Fluke 271 manual MODE Keys, UTILITIES Keys, OUTPUT Key, Getting Started, RECALL and REMOTE

Page 17
MODE Keys

Getting Started

Controls and Connections

MODE Keys

Alternate presses of a MODE key will turn the mode

(TRIG, GATE, AM, etc.) on or off, and when the function is on the associated lamp is lit.

If you press the EDIT key then press a MODE key you will see the edit menu for that mode. The associated lamp flashes when the edit menu is displayed.

Some of the modes share keys with the numeric keypad. For example, to see the edit screens for HOP mode, press EDIT then the numeric 5 key.

To return to the main menu from any edit menu, press the ESCAPE key.

shx0010f.gif

UTILITIES Keys

 

The UTILITIES keys give

 

access to the STORE,

 

RECALL and REMOTE

 

edit menus. The instrument

 

can store up to nine set-ups

 

(numbered 1 to 9), and can

 

recall any of those plus

 

set-up 0 which is the factory

 

default set-up and is not

 

editable.

shx0011f.gif

 

The MAN/SYNC key is used for manual triggering and synchronizing two or more generators when suitably connected together. Further information on synchronizing two generators is given in the Users Manual.

OUTPUT Key

The OUTPUT key turns the MAIN OUT on and off. When the output is on the LED next to the key is lit.

The default state at power-shx0018f.gif up is with the output off.

7

Image 17
Contents Programmable 10 MHz DDS Function Generator Getting Started ManualTo register your product online, visit register.fluke.com LIMITED WARRANTY AND LIMITATION OF LIABILITYSafety Getting Started Manual The following symbols are used on the instrument and in this manual Safety continuedTerminal connected to chassis ground Mains supply OFF Mains supply ON Alternating current Warning - hazardous voltages may be presentPage Immunity EMC ComplianceEmissions e EN61000-4-5 1995 Surge 0.5 kV line to line, 1 kV line to ground Title Table of ContentsAUX OUT viiiIntroduction Getting StartedBefore You Start Mains Supply VoltageExternally Applied Voltages Getting Started Controls and ConnectionsFigure 1. Model 271 Front Panel shx0001f.gifFunction Keys The Liquid Crystal DisplayControls FIELD and DIGIT Keys and the Rotary Control Numeric, Units and SET Keys UTILITIES Keys MODE KeysOUTPUT Key RECALL and REMOTEEXT TRIG Front Panel Inputs and OutputsMAIN OUT AUX OUTCLOCK IN/OUT Rear Panel ConnectorsVCA IN SYNC OUTTRIG/SWEEP OUT RS232 and GPIB Interface ConnectorsPlug in and switch on the instrument Using the InstrumentStarting up Check the LCD DisplaySet a frequency, for example 12.5 kHz Generating Continuous SignalsFREQ=12.50000kHz VhiZ=+20.0 Vpp 50Ω DC=+0.00mV +0.00mV SYM=50.0% 50.0%Have a look at some other waveforms Set the amplitude to +10 dBmChange the dc offset =80.00000usPER =80.00000us VhiZ=+4.00 Vpp 50Ω DC=+1.50 V +151.mV SYM=50.0% 50.0% Effect of the output attenuatorDC OFFSET CHANGE * * BY OUTPUT LEVEL SOURCE=EXT TGEN=1.00ms 1.000kHz BURST COUNT= PHASE=+000 +000 Adjusting the phaseSOURCE=EXT TGEN=1.00ms 1.000kHz BURST COUNT= PHASE=+116 +116 Asymmetric waveformsTRIG/SWEEP OUT signal Generating Swept SignalsBEG FRQ=261.6000 Hz END FRQ=1.108700kHz MARK FRQ=523.3000 Hz MORE MODE=BEG-END LAW=LOG RAMP TIME=0.05 s TRIG SRC=CONTINUOUS MOREMODE=BEG-END LAW=LOG RAMP TIME=5.00 s TRIG SRC=CONTINUOUS MORE PHASE=+000 +000 SOURCE=EXT TGEN=1.00ms 1.000kHz BURST COUNT=0001 PHASE=+000 +000Generating a Triggered Burst FREQ=2.000000kHz VhiZ=+20.0 Vpp 50Ω DC=+0.00mV +0.00mVSpecial Waveforms FSK ModeStaircases FREQ A=800.0000 Hz FREQ B=1.200000kHz SOURCE=TGEN FREEFigure 2. 625-line PAL TV Signal name stepstart µs amplitudeVALS=ABS AUTO=YES STEP=08 ACTIVE LENGTH=0005 LEVEL=+153 VALS=ABS AUTO=YES STEP=01 ACTIVE LENGTH=0256 LEVEL=+000Arbitrary Waveforms Saving and Recalling SettingsRECALL ARB No SINX/X ENTER TO EXECUTE RECALL ARB No ARB 03 IS EMPTYOther Functions and Waveforms