Generating Continuous Signals
Rear Panel Connectors
Adjusting the phase
PHASE=+000 +000
Saving and Recalling Settings
Safety
Using the Instrument
Page 6
Page 5
Page 7
Image 6
Page 5
Page 7
Contents
Getting Started Manual
Programmable 10 MHz DDS Function Generator
LIMITED WARRANTY AND LIMITATION OF LIABILITY
To register your product online, visit register.fluke.com
Safety
Getting Started Manual
Terminal connected to chassis ground Mains supply OFF Mains supply ON
Safety continued
The following symbols are used on the instrument and in this manual
Alternating current Warning - hazardous voltages may be present
Page
EMC Compliance
Emissions
Immunity
e EN61000-4-5 1995 Surge 0.5 kV line to line, 1 kV line to ground
Table of Contents
Title
viii
AUX OUT
Before You Start
Getting Started
Introduction
Mains Supply Voltage
Externally Applied Voltages
Figure 1. Model 271 Front Panel
Controls and Connections
Getting Started
shx0001f.gif
The Liquid Crystal Display
Controls
Function Keys
FIELD and DIGIT Keys and the Rotary Control
Numeric, Units and SET Keys
OUTPUT Key
MODE Keys
UTILITIES Keys
RECALL and REMOTE
MAIN OUT
Front Panel Inputs and Outputs
EXT TRIG
AUX OUT
VCA IN
Rear Panel Connectors
CLOCK IN/OUT
SYNC OUT
RS232 and GPIB Interface Connectors
TRIG/SWEEP OUT
Starting up
Using the Instrument
Plug in and switch on the instrument
Check the LCD Display
FREQ=12.50000kHz VhiZ=+20.0 Vpp 50Ω DC=+0.00mV +0.00mV
Generating Continuous Signals
Set a frequency, for example 12.5 kHz
SYM=50.0% 50.0%
Change the dc offset
Set the amplitude to +10 dBm
Have a look at some other waveforms
=80.00000us
Effect of the output attenuator
DC OFFSET CHANGE * * BY OUTPUT LEVEL
PER =80.00000us VhiZ=+4.00 Vpp 50Ω DC=+1.50 V +151.mV SYM=50.0% 50.0%
SOURCE=EXT TGEN=1.00ms 1.000kHz BURST COUNT= PHASE=+116 +116
Adjusting the phase
SOURCE=EXT TGEN=1.00ms 1.000kHz BURST COUNT= PHASE=+000 +000
Asymmetric waveforms
Generating Swept Signals
TRIG/SWEEP OUT signal
MODE=BEG-END LAW=LOG RAMP TIME=0.05 s TRIG SRC=CONTINUOUS MORE
MODE=BEG-END LAW=LOG RAMP TIME=5.00 s TRIG SRC=CONTINUOUS MORE
BEG FRQ=261.6000 Hz END FRQ=1.108700kHz MARK FRQ=523.3000 Hz MORE
Generating a Triggered Burst
SOURCE=EXT TGEN=1.00ms 1.000kHz BURST COUNT=0001 PHASE=+000 +000
PHASE=+000 +000
FREQ=2.000000kHz VhiZ=+20.0 Vpp 50Ω DC=+0.00mV +0.00mV
Staircases
FSK Mode
Special Waveforms
FREQ A=800.0000 Hz FREQ B=1.200000kHz SOURCE=TGEN FREE
Figure 2. 625-line PAL TV Signal
start µs
step
name
amplitude
VALS=ABS AUTO=YES STEP=01 ACTIVE LENGTH=0256 LEVEL=+000
VALS=ABS AUTO=YES STEP=08 ACTIVE LENGTH=0005 LEVEL=+153
RECALL ARB No SINX/X ENTER TO EXECUTE
Saving and Recalling Settings
Arbitrary Waveforms
RECALL ARB No ARB 03 IS EMPTY
Other Functions and Waveforms
Related pages
Troubleshooting for Vornado Whole Room Heater
Technical Specifications for Zanussi ZJ 1284
Terminal Block Wiring Diagrams for Honeywell HC900
When replacing hotplate burner parts for Electrolux SIG 332
Universal Mounting Bracket Installation for Spalding 211878
Replacement Parts List Electronic System for TOA Electronics P0055-DRG
VCR Code List VCR Brand Name for JVC GR-HD1
Can I adjust EQ settings in the Vox AD50VT?
Discover options
Top
Page
Image
Contents