Using the Instrument

Getting Started

Using the Instrument

Using the Instrument

While familiarizing yourself with the instrument you will find it useful to observe the outputs on an oscilloscope. For most purposes it is sufficient to connect the MAIN OUT front panel socket to the oscilloscope's Y input, and the AUX OUT front panel socket to the oscilloscope's trigger input.

If no oscilloscope is available you can still learn a great deal about the instrument settings, since the effect of front-panel operations is visible in the LCD display in the form of text messages, parameter information, menus and status information.

Starting up

The ac supply on/off switch is located at the bottom left side of the front panel.

Starting up Caution

Before connecting to the ac supply, check that the supply voltage setting is correct for the region. Please refer to the Users Manual if it needs to be changed.

Plug in and switch on the instrument

On power-up the LCD panel illuminates and the instrument performs a series of self tests. In the event that an error message is displayed please refer to the Users Manual.

Check the LCD Display

It should look similar to the main menu shown in figure 1. If not, press RECALL, 0, ENTER to bring up the factory default main menu.

11

Image 21
Contents Programmable 10 MHz DDS Function Generator Getting Started ManualTo register your product online, visit register.fluke.com LIMITED WARRANTY AND LIMITATION OF LIABILITYSafety Getting Started Manual The following symbols are used on the instrument and in this manual Safety continuedTerminal connected to chassis ground Mains supply OFF Mains supply ON Alternating current Warning - hazardous voltages may be presentPage EMC Compliance EmissionsImmunity e EN61000-4-5 1995 Surge 0.5 kV line to line, 1 kV line to ground Title Table of ContentsAUX OUT viiiIntroduction Getting StartedBefore You Start Mains Supply VoltageExternally Applied Voltages Getting Started Controls and ConnectionsFigure 1. Model 271 Front Panel shx0001f.gifThe Liquid Crystal Display ControlsFunction Keys FIELD and DIGIT Keys and the Rotary Control Numeric, Units and SET Keys UTILITIES Keys MODE KeysOUTPUT Key RECALL and REMOTEEXT TRIG Front Panel Inputs and OutputsMAIN OUT AUX OUTCLOCK IN/OUT Rear Panel ConnectorsVCA IN SYNC OUTTRIG/SWEEP OUT RS232 and GPIB Interface ConnectorsPlug in and switch on the instrument Using the InstrumentStarting up Check the LCD DisplaySet a frequency, for example 12.5 kHz Generating Continuous SignalsFREQ=12.50000kHz VhiZ=+20.0 Vpp 50Ω DC=+0.00mV +0.00mV SYM=50.0% 50.0%Have a look at some other waveforms Set the amplitude to +10 dBmChange the dc offset =80.00000usEffect of the output attenuator DC OFFSET CHANGE * * BY OUTPUT LEVELPER =80.00000us VhiZ=+4.00 Vpp 50Ω DC=+1.50 V +151.mV SYM=50.0% 50.0% SOURCE=EXT TGEN=1.00ms 1.000kHz BURST COUNT= PHASE=+000 +000 Adjusting the phaseSOURCE=EXT TGEN=1.00ms 1.000kHz BURST COUNT= PHASE=+116 +116 Asymmetric waveformsTRIG/SWEEP OUT signal Generating Swept SignalsMODE=BEG-END LAW=LOG RAMP TIME=0.05 s TRIG SRC=CONTINUOUS MORE MODE=BEG-END LAW=LOG RAMP TIME=5.00 s TRIG SRC=CONTINUOUS MOREBEG FRQ=261.6000 Hz END FRQ=1.108700kHz MARK FRQ=523.3000 Hz MORE PHASE=+000 +000 SOURCE=EXT TGEN=1.00ms 1.000kHz BURST COUNT=0001 PHASE=+000 +000Generating a Triggered Burst FREQ=2.000000kHz VhiZ=+20.0 Vpp 50Ω DC=+0.00mV +0.00mVSpecial Waveforms FSK ModeStaircases FREQ A=800.0000 Hz FREQ B=1.200000kHz SOURCE=TGEN FREEFigure 2. 625-line PAL TV Signal name stepstart µs amplitudeVALS=ABS AUTO=YES STEP=08 ACTIVE LENGTH=0005 LEVEL=+153 VALS=ABS AUTO=YES STEP=01 ACTIVE LENGTH=0256 LEVEL=+000Arbitrary Waveforms Saving and Recalling SettingsRECALL ARB No SINX/X ENTER TO EXECUTE RECALL ARB No ARB 03 IS EMPTYOther Functions and Waveforms