MAJOR GENERATOR FEATURES

 

FUEL TANK VENTING

 

 

 

*3.5 HP Briggs & Stratton engine

*Receptacles on endbell

*1.35 gallon plastic fuel tank

*Spark arrester

*Brushless generator

ENDBELL

CAUTION: Keep fuel tank area free of all debris, water, and ice. Do not block vent. “Tank must breathe.”

A . 120 V, 15 Ampere Duplex Receptacles

15 amps of current may be drawn from each half of the receptacle. However, total power drawn must be kept within nameplate ratings.

B.Circuit Breaker

The receptacles are protected by an AC circuit breaker. If

the generator is overloaded or an external short circuit occurs, the circuit breaker will trip. If this occurs, disconnect all electrical loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit breaker to trip, reduce the load. NOTE:

Continuous tripping of the circuit breaker may cause damage to generator or equipment. The circuit breaker may be reset by pushing the button of the breaker.

C.Engine Switch

SPARK ARRESTER MUFFLER

This engine is equipped with a U.S. Forest Service approved spark arrest muffler. It should periodically be cleaned to prevent the screen from becoming clogged, which could hamper engine performance.

To clean, remove the muffler shield. Remove the four screws and pull the plate with the screen attached. Clean off any particles with a brush and reinstall. Be sure gasket is in place.

ENGINE MAINTENANCE SCHEDULE

 

 

Check engine oil

. . . . . . . . . . Before each use

 

 

Change engine oil

After first 20 hours and then

RECEPTACLE PANEL

RECOIL PANEL

 

 

Clean air filter

every 50 hours of operation

 

 

. Every 50 hours of operation

 

 

Clean spark plug

Every 100 hours of operation

 

 

Clean spark arrestor

. Every 50 hours of operation

Oil Type. Use new good quality oil such as SC, SD, and SE grades. The oil to be used depends upon the temperature at which the engine is operated:

Summer: (temperatures of over 40 degrees F/10 degrees

C) SAE 30 or SAE 10W-30, SAE 10W-40

Winter: (temperatures of below 40 degrees F/10 degrees C) SAE 20 or SAE 10W-30

 

 

English

2

 

 

Image 2
Contents PM0401858 Endbell Major Generator Features Fuel Tank VentingEngine Maintenance Schedule Spark Arrester MufflerLimited Warranty Not CoveredLE Silencieux PARE-ETINCELLES Caractéristiques Principales DU Groupe ElectrogeneCOVRE-ENROULEMENT LE Plan Dentretien DE MoteurGarantie Limitée Ce qui nest pas couvertEL Horario DE LA Mantenimiento DEL Motor Caracteristicas Principales DEL GeneradorSilenciador DEL Arrestor DE Chispas Receptáculos dúplex de 120 voltios, 15 amperesGarantia Limitada No están cubiertosParts Drawing / Schema DES Pièces / Diagrama DE Piezas Parts List / Liste DES Pièces / Lista DE Piezas Page Page Powermate Corporation