Generac 04675-3, 04673-2, 04674-2 owner manual Part NO. QTY Description

Page 37

Section 7 — Exploded Views and Parts Lists

Generac Air-cooled 7 kW, 12 kW and 15 kW Generators

Control Panel – Drawing No. 0E7974-G

ITEM

PART NO. QTY.

DESCRIPTION

 

ITEM

PART NO. QTY.

DESCRIPTION

1

0E7886A

1

CIRCUIT BREAKER 30A X 2P 240V (7KW)

24

0D8502

1

NEUTRAL CONNECTOR

 

0E7886C

1

CIRCUIT BREAKER 40A X 2P 240V

26

0D8441

1

HARNESS, CONTROL PANEL (NOT

 

 

 

(8.5KW)

 

 

 

 

SHOWN)

 

0E7886D

1

CIRCUIT BREAKER 45A X 2P 240V (11KW)

 

 

0E0120

1

HARNESS, CONTROL PANEL WIRE (NOT

 

0E7886E

1

CIRCUIT BREAKER 50A X 2P 240V (12KW)

 

 

 

 

SHOWN) (7KW)

 

0E7886F

1

CIRCUIT BREAKER 60A X 2P 240V (13KW)

27

074908

4

SCREW TAPTITE, M5-0.8 x 10 BP

 

0E7886G

1

CIRCUIT BREAKER 70A X 2P 240V (15KW)

29

082025

6

NUT HEX LOCK M5-0.8 NYLON INSERT

2

0A1801

1

ASSEMBLY, BATTERY CHARGER ENGINE

30

0C3910

1

TRANSFORMER

3

083049

1

ASSEMBLY, POTTED REGULATOR

31

022507

2

SCREW HHC 1/4"-20 x 1/2"

4

0C2174

1

RELAY, 12V 25A SPST

32

099727

1

FUSE 5A X AGC5

5

075210A

1

BLOCK 1 POSITION

33

046689

1

BLOCK TERMINAL STRIP 20A 4 X 6 X

6

0D3062

4

HEX STAND-OFF #6-32 x 3/8"

 

 

 

 

1100V

7

0D8615

1

ASSEMBLY, HOME STANDBY

34

063617

1

RELAY PANEL 12VDC DPDT 10A 240VAC

 

 

 

CONTROLLER

35

075475

2

SCREW PPHM M4-0.7 x 10mm

 

0D8615A

1

ASSEMBLY, HOME STANDBY

36

043180

2

WASHER FLAT M4

 

 

 

CONTROLLER (7KW)

37

0D8439

1

COVER, CONTROL PANEL COMPONENT

8

032300

2

HOLDER, FUSE

 

 

0E0119

1

COVER, CONTROL PANEL COMPONENT

9

022676

1

FUSE, 15AMP X AGC15

 

 

 

 

(7KW)

10

0E4494

1

SWITCH, ROCKER DPDT ON-OFF-ON

38

092036

8

SCREW PPHMS/LW #6-32 x 1/4"

11

0E7890

1

CIRCUIT BREAKER MOUNTING BRACKET

39

045770

2

SCREW HHC M5-0.8 x10mm

12

023484E

1

SNAP BUSHING

40

0E7866

1

COVER, CONTROL PANEL

13

075476

4

SCREW PPHM M4-0.7 x 16mm

 

 

0E7867

1

COVER, CONTROL PANEL (7KW)

15

0E6480

6

NUT HEX LOCK M4-0.7 NYLON INSERT

41

0D3700

8

NUT FLANGE M6-1.0 NYLOK

17

0C1085

4

SCREW PPHM M3-0.5 X 8mm

42

0912970069

1

ASSEMBLY, ROOF/DOOR GROUND WIRE

 

0C1085

2

SCREW PPHM M3-0.5 X 8mm (7KW)

43

0E2874

1

SCREW HHTR 1/4"-20 X 3/4"

18

0D8443

1

DECAL, CONTROL PANEL (NOT SHOWN)

44

0A1658

2

WASHER LOCK SPECIAL 1/4"

19

054502

1

CIRCUIT BREAKER 3 X 1 ETA 46-500-P

45

022473

3

WASHER FLAT 1/4"-M6

 

053623

1

CIRCUIT BREAKER 2.5 X 1 ETA 46-500-P

46

038750

1

SCREW HHC M6-1.0 x 30mm

 

 

 

(7KW)

47

022097

3

WASHER LOCK M6-1/4"

20

0E7870

1

CONTROL, PANEL BOTTOM

48

049813

1

NUT HEX M6-1.0

 

0E7871

1

CONTROL, PANEL BOTTOM (7KW)

49

031879

6

WASHER FLAT #4

21

075235

4

SCREW HHC M5-0.8 x 30mm

 

 

031879

4

WASHER FLAT #4 (7KW)

22

0D5240

1

SWITCH, SPST (ON)-ON N/O

50

023897

2

WASHER FLAT #10

23

0D9784

6

NUT HEX LOCK M3-0.5 NYLON INSERT

51

0F4793

2

SCREW PPHM M3-0.5 x 10mm

 

0D9784

4

NUT HEX LOCK M3-0.5 NYLON INSERT

 

 

 

 

 

 

 

 

(7KW)

 

 

 

 

 

Generac® Power Systems, Inc. 35

Image 37
Contents Installation Authorized Dealer Location IntroductionMaintenance Post Installation Start-up AdjustmentsTroubleshooting Introduction Inside Front CoverGeneral Hazards ‹ Standards Index Electrical HazardsProtection Systems UNPACKING/INSPECTIONSystem SET LED Gfci Generator‹ 1.5.1 Generator Specifications‹ 1.5.2 Engine Fuel Requirements Recommendations Reconfiguring the Fuel SystemFuel Consumption 1 7 KW, 410CCLocation Transfer SwitchGenerator 2.1 7 kW, 12 kW and 15 kW UnitsBattery Battery InstallationBefore Initial START-UP Check Transfer Switch OperationElectrical Checks Checking Automatic Operation Generator Tests Under LoadEngine Governor Adjustment Adjusting the Regulator Natural GAS only1 7 KW Units 2 12 KW and 15 KW Units Voltage Regulator AdjustmentAutomatic Transfer Operation BREAK-IN ProcedureSequence of Automatic Operation ‹ 3.2.1 Auto PositionManual Transfer Operation ‹ 3.5.2 Transfer Back to Utility Power Source‹ 3.7.1 LOW OIL Pressure Switch Setting the Exercise Timer‹ 3.7.2 High Temperature Switch ‹ 3.7.3 OvercrankChanging the Engine OIL Checking the Engine OIL LevelApproximate Crank Cycle Times ‹ 3.7.4 OverspeedChanging the OIL Filter ‹ 4.3.2 OIL Change Procedure‹ 4.5.1 7 KW, 12 KW and 15 KW Generators Spark Plugs Battery MaintenanceCooling System Adjusting Valve Clearance‹ 4.12.2 Return to Service OUT of Service Procedure‹ 4.12.1 Removal from Service Corrosion ProtectionSYSTEM/COMPONENT Procedure Frequency Service ScheduleProblem Cause Correction Troubleshooting GuideElectrical Data Customer Battery Utility Battery Charger Utility Connection BCR SW1 Exploded Views and Parts Lists Part NO. QTY. Description Exploded Views and Parts Lists Part NO. QTY Description 1310 Sleeve Exploded Views and Parts Lists Item Part NO. QTY. Description 14 20 QTY Description Exploded Views and Parts Lists Stator 12KW Exploded Views and Parts Lists PIN, Piston D20 Exploded Views and Parts Lists SCREW, Taptite M6-1.0X8 Yellow Chrome Exploded Views and Parts Lists CASTING, Twin Regulator Housing Dimensions Generac Air-cooled 7 kW, 12 kW and 15 kW Generators MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule
Related manuals
Manual 59 pages 50.68 Kb

04674-2, 04675-3, 04673-2 specifications

Generac, a prominent name in the power equipment sector, offers a range of reliable and efficient energy solutions, including the models Generac 04673-2, 04675-3, and 04674-2. These models are designed to meet diverse consumer needs, from residential applications to larger commercial setups, providing dependable backup power during outages.

The Generac 04673-2 is a standout home standby generator specifically engineered for residential use. It boasts an automatic operation feature, ensuring that power is restored within seconds of an outage. This model operates on a robust Generac engine, delivering a reliable power output that can support essential household appliances and systems, including HVAC units, refrigerators, and sump pumps. One of the main characteristics of this generator is its Quiet Test mode, which runs at a lower RPM to minimize noise while conducting weekly self-tests, ensuring that the system is always ready when needed.

Moving on to the Generac 04675-3, this model offers enhanced features tailored for users needing higher power output. With a larger capacity, it can handle more demanding power needs, making it suitable for larger homes or small businesses. The 04675-3 is equipped with advanced technologies, including the Mobile Linkā„¢ remote monitoring system, which enables users to check the status and performance of their generator from anywhere using a smartphone or computer. This connectivity empowers users with real-time information and alerts regarding their generator's operational performance.

The Generac 04674-2 model rounds out the trio, engineered for those who need a powerful standby generator with a slightly different configuration. It features the same robust engine as the other models, ensuring reliability and user-friendly operation. Its standout feature is the integrated transfer switch capability, which allows for seamless transfer of power from the grid to the generator without manual intervention. This model also supports various fuel types, providing flexibility depending on user preference and availability.

All three Generac models focus on safety and efficiency, incorporating features such as excellent ventilation systems, all-weather enclosures, and user-friendly control panels. They are designed for low maintenance, ensuring long-lasting performance without extensive upkeep. With Generac's commitment to innovation and quality, these generators offer peace of mind, enabling users to maintain their lifestyles and operations without interruption during power outages. Whether for home or business use, the Generac 04673-2, 04675-3, and 04674-2 models represent a reliable choice in emergency power solutions.