6.6 Remote Control Commands

The diagram below gives the front panel keys and their associated ASCII codes. Sending these characters to the 4070A has the same effect as pressing the associated button on the front panel.

NOTE: To familiarize yourself with the remote operation of the 4070A, it is helpful to run a terminal program on your PC and manually type the commands and watch the response. To get a help menu, press H. See section 6.3 for details. Characters are case insensitive

Front Panel Programming

One Touch

 

Mode Selection

Digit Field

V

 

é U

 

 

 

 

 

Value

 

 

 

G

 

ê D

 

 

Q

 

èR

 

 

Position

 

 

 

B

 

çL

7

SSB

4

Sweep

1

AM

.

*

8

DTMF Gen

5

FSK

2

FM

0

Power

Measure

9

DTMF Det

6

Burst

3

M

-

#

Z

Y

X

C

Other

M H z dBm

K H z

Vp-p

Sec

H z

MV p-p m S

Clear

×Ø

P N

Field

S T

RecallTrigger Store

O M

OffsetMode

S Y N C

Out

SIG

Out

Figure 6.6-1: Front panel keys to ASCII command mapping

NOTE: Turning the rotary knob clockwise has the same effect as pressing the é key multiple times. Turning the rotary knob Counter-clockwise has the same effect as pressing the ê key multiple times. In addition to the above ASCII command characters, extra commands are available for remote control operation.

They are:

A- Reset the unit to Sine wave mode

V- Report hardware and software versions

K1,0 - Enable, Disable front panel keys and knob

E1,0 - Enable, Disable LCD echo to terminal

F0-9 - Move cursor to field 0 to 9 ? or H - Print help menu

^E

- Returns ^C

Each of these "extra" remote control commands is discussed below:

A - Reset 4070A to Sine wave mode

This command resets the 4070A to the Sine wave mode and turns the cursor off. The output-offset voltage is set to 0.0V. When writing control software for the 4070A, it is a good idea to issue this command first so that the 4070A is in a known state before further commands are issued.

NOTE: The frequency and level values are not reset. They are set to the values that existed the last time the unit was in Sine wave mode. (Or the power-up default values if they hadn't been changed). The RS-232 baud rate remains unchanged.

42

BK Precision 4070A User Manual Rev.2.2

Image 47
Contents User’s Manual Page +K Precision Corp Model 4070A User’s ManualTable of Contents DC Operation Option Warranty informationRemote operation Arbitrary waveform systemIntroduction Description Modes Feature summarySIG Out connector Installation and setupSync out connector External Modulation In connector External Trigger/Gating/FSK/BPSK input Line in connector External Reference Input / Ext Arb. Clock connectorExternal Arb Sync In / Out connector RS232 Interface connectorRecall / Store key Mode keyOperating controls and keys Field arrow keysÉ, ê, è, ç keys Trigger keyNumeric keys 0 to 9, MHz/dBm, KHz/Vp-p/Sec, Hz/mVp-p/mS keys One Touch Mode KeysClear key Changing level Operating mode selectionOperating guide Changing frequencyEntering a new value Changing valuesModifying an existing value Sinewave Mode 000,000.00 Hz 10.0 dBm Mode descriptionsBasic Sinewave CW Mode Internal AM Mode Input Gain External AM ModeExternal AM Mode Parameters External AM Input gain 000,000.00 Hz PEP level -10.0 dBmPeak Frequency Deviation Internal FM ModeInternal FM Mode Parameters Int FM 1,000 Hz Pk dev 10,000 Hz 000,000.00 Hz 10.0 dBmExternal FM Pk dev 10,000 Hz 000,000.00 Hz 10.0 dBm External FM ModeExternal FM Mode Parameters Int PM 1,000 Hz Pk dev 180 deg 000,000.00 Hz 10.0 dBm Internal PM ModeInternal PM Mode Parameters Peak Phase DeviationExternal PM Pk dev 180 deg 000,000.00 Hz 10.0 dBm External PM ModeExternal PM Mode Parameters Sweep Mode Sweep time Up / Down sweepSpace Frequency Internal FSK ModeInternal FSK Mode Parameters Mark FrequencyExt FSK Input External FSK ModeExternal FSK Mode Parameters Ext FSK Mark 1,000,000.00 Hz Space 2,000,000.00 Hz 10.0 dBmBurst frequency Burst Mode IntroductionBurst Mode Trig Ton 10,000 mS 000,000.00 Hz Off 10.0 dBm Upper/Lower Sideband selections Internal SSB ModeInternal SSB Mode Parameters Int SSB 1,000 Hz Upper Sideband 000,000.00 Hz 10.0 dBmExternal SSB Upper Sideband 000,000.00 Hz +10.0 dBm External SSB ModeExternal SSB Mode Parameters Background Dtmf Generation ModeDtmf generation # Duration 200 mS Delay Level -10.0 dBm Dtmf Generation Mode ParametersDtmf Duration Dtmf DelayDtmf detected digits Dtmf Detection ModeDtmf Detection Mode Parameters Dtmf detection on Ext Mod input 3 # aVoltage Level Power & Voltage Measurement ModePower & Voltage Measurement Mode Parameters Power LevelOther mode Arbitrary ModeRemote Mode Int Bpsk 1,000 Hz 000,000.00 Hz 10.0 dBm Internal Bpsk ModeInternal Bpsk Mode Parameters External Bpsk 000,000.00 Hz 10.0 dBm External Bpsk ModeExternal Bpsk Mode Parameters 10,000 Hz F2 Ton 000 mS Toff 10.0 Dualtone Generation ModeDualtone Examples Baud Rate Data Modulation ModeUsing the Data Modulation Mode Data Modulation Mode ParametersExample Message Downloading Modulation Message DataSaving the Message Triggering the TransmissionEnd Frequency Voltage Controlled Oscillator VCO ModeVCO Mode Parameters Start End 1,000,000.00 Hz 10.0 dBmChecking your connection with Hyper Terminal ConnectingRemote Operation Remote Control Programming Rules Remote Control OperationReturns C Remote Control CommandsReset 4070A to Sine wave mode × ØReport hardware and software versions K1.0 Enable, Disable front panel keys and rotary knobE1,0 Enable, Disable LCD echo to terminal Return a C Linear Trig Up Time 10,000 mSF0-9 Move cursor to field 0 to ? or H Print help menuExample Remote Control ExamplesPin 9-pin cable Pin 25 pin cable adapter Arbitrary Waveform ModeQuick Start Guide Description of the Arbitrary Waveform Generator Introduction to the Arbitrary Waveform SystemPulse Generator Switching ModesFeature Summary Function GeneratorContinuous/Triggered mode Arbitrary Waveform ModeInt Clock / Ext Clock / Lock Master Lock slave mode PhaseRepetition Frequency Function Generator ModeFunction Gen Wave Pos Ramp Rep Freq 100,000 Hz 000 mV WaveformDuty Cycle Pulse Generator ModePositive Only Cwaveload /COMx /y /baudz filename.ext Using WAVELOAD.EXEDownloading arbitrary waveforms Saving Arbitrary WaveformsUsing your own program Rules for Floating Point format Data FormatsFloating Point Format Example #2 Time & Value Floating Point FormatDigital Format Integer Format Example The data value E468 is handled as follows Hexadecimal FormatRules for Hexadecimal format Example Binary FormatRules for Binary format Generator Multiple Units LockingArb Waveform Size Restrictions More on Phase OffsetsPhase Resolution Starting Address = Number of waveform points * Phase OffsetProgram Listing ARB.BAS Example Arb ProgramClose System Subroutines Return Print #1, a Send integer value to 4070A Return Return DC Operation Option Wiring DiagramOperating Modes 4070A SpecificationsRemote Software CDAppendix a Hardware SetupCLS CLS Print Print Subroutines END SUB Appendix B Television Remote Control ExampleCLS Make sure a 4070A is attached to the serial port Print Limited Two-Year Warranty Service Information Savi Ranch Pkwy Yorba Linda, CA 92887 USA TEL