Page 76
10.0 Software CD
Description
The compact disk, which accompanies this manual, contains a number of useful utilities and example programs, which are in directory /disc 4071. Due to similarity in firmware structure BK models 4070A and 4071 both are compatible with this software, except frequency range. Below is a list of the directories on this disk and a description of the files within each. Within each directory is a file called README, which explains the purpose of the files in that directory. The files and their purpose are listed here as a convenient reference:
CALIBRATE
SG100CAL.EXE | - A utility to calibrate |
SG100CAL.TXT | - Documentation file. |
REMOTE | |
APP1.BAS | - Source code for program in Appendix A |
APP2.BAS | - Source code for program in Appendix B |
UPDATE | |
NOTE: This directory contains a utility to update the operating software, firmware.
SGLOAD.EXE | - Utility which sends the update file to the unit. |
SGLOAD.TXT | - Documentation file. |
*.TLX | - Operating software data file. “16” means software version 1.6. The name of |
ARB | this file changes with each new software release. |
|
WAVELOAD.EXE | - Utility to download arbitrary waveform files to the Arb generator over the |
| serial port. |
WAVELOAD.DOC | - Documentation file. |
ARB.BAS | - Example program to generate waveforms in all supported data formats. |
EXAMPLES | - Directory containing arbitrary waveform files in all supported formats. |
71
BK Precision 4071 User Manual Rev.2.2
Contents
User’s Manual
Page
Model User’s Manual
+K Precision Corp
Table of Contents
Warranty information
Remote operation
Arbitrary waveform system
DC Operation Option
Introduction
Description
Feature summary
Modes
Sync out connector
Installation and setup
SIG Out connector
External Modulation In connector
External Trigger/Gating/FSK/BPSK input
External Reference Input / Ext Arb. Clock connector
External Arb Sync In / Out connector
RS232 Interface connector
Line in connector
Mode key
Operating controls and keys
Field arrow keys
Recall / Store key
Numeric keys 0 to 9,
Trigger key
É, ê, è, ç keys
Clear key
One Touch Mode Keys
MHz/dBm, KHz/Vp-p/Sec, Hz/mVp-p/mS keys
Operating mode selection
Operating guide
Changing frequency
Changing level
Modifying an existing value
Changing values
Entering a new value
Basic Sinewave CW Mode
Mode descriptions
Sinewave Mode 000,000.00 Hz 10.0 dBm
Internal AM Mode
External AM Mode
External AM Mode Parameters
External AM Input gain 000,000.00 Hz PEP level -10.0 dBm
Input Gain
Internal FM Mode
Internal FM Mode Parameters
Int FM 1,000 Hz Pk dev 10,000 Hz 000,000.00 Hz 10.0 dBm
Peak Frequency Deviation
External FM Mode Parameters
External FM Mode
External FM Pk dev 10,000 Hz 000,000.00 Hz 10.0 dBm
Internal PM Mode
Internal PM Mode Parameters
Peak Phase Deviation
Int PM 1,000 Hz Pk dev 180 deg 000,000.00 Hz 10.0 dBm
External PM Mode Parameters
External PM Mode
External PM Pk dev 180 deg 000,000.00 Hz 10.0 dBm
Sweep Mode
Up / Down sweep
Sweep time
Internal FSK Mode
Internal FSK Mode Parameters
Mark Frequency
Space Frequency
External FSK Mode
External FSK Mode Parameters
Ext FSK Mark 1,000,000.00 Hz Space 2,000,000.00 Hz 10.0 dBm
Ext FSK Input
Burst Mode Trig Ton 10,000 mS 000,000.00 Hz Off 10.0 dBm
Burst Mode Introduction
Burst frequency
Internal SSB Mode
Internal SSB Mode Parameters
Int SSB 1,000 Hz Upper Sideband 000,000.00 Hz 10.0 dBm
Upper/Lower Sideband selections
External SSB Mode Parameters
External SSB Mode
External SSB Upper Sideband 000,000.00 Hz 10.0 dBm
Dtmf Generation Mode
Dtmf generation # Duration 200 mS Delay Level -10.0 dBm
Dtmf Generation Mode Parameters
Background
Dtmf Delay
Dtmf Duration
Dtmf Detection Mode
Dtmf Detection Mode Parameters
Dtmf detection on Ext Mod input 3 # a
Dtmf detected digits
Power & Voltage Measurement Mode
Power & Voltage Measurement Mode Parameters
Power Level
Voltage Level
Remote Mode
Arbitrary Mode
Other mode
Internal Bpsk Mode Parameters
Internal Bpsk Mode
Int Bpsk 1,000 Hz 000,000.00 Hz 10.0 dBm
External Bpsk Mode Parameters
External Bpsk Mode
External Bpsk 000,000.00 Hz 10.0 dBm
Dualtone Generation Mode
10,000 Hz F2 Ton 000 mS Toff 10.0
Dualtone Examples
Data Modulation Mode
Using the Data Modulation Mode
Data Modulation Mode Parameters
Baud Rate
Downloading Modulation Message Data
Example Message
Triggering the Transmission
Saving the Message
Voltage Controlled Oscillator VCO Mode
VCO Mode Parameters
Start End 1,000,000.00 Hz 10.0 dBm
End Frequency
Remote Operation
Connecting
Checking your connection with Hyper Terminal
Remote Control Operation
Remote Control Programming Rules
Remote Control Commands
Reset 4071 to Sine wave mode
× Ø
Returns C
E1,0 Enable, Disable LCD echo to terminal
K1.0 Enable, Disable front panel keys and rotary knob
Report hardware and software versions
Stp 31,500,000.00 Hz
Linear Trig Up Time 10,000 mS
F0-9 Move cursor to field 0 to
? or H Print help menu
Remote Control Examples
Example
Quick Start Guide
Arbitrary Waveform Mode
Pin 9-pin cable Pin 25 pin cable adapter
Introduction to the Arbitrary Waveform System
Description of the Arbitrary Waveform Generator
Switching Modes
Feature Summary
Function Generator
Pulse Generator
Arbitrary Waveform Mode
Int Clock / Ext Clock / Lock Master Lock slave mode
Phase
Continuous/Triggered mode
Function Generator Mode
Function Gen Wave Pos Ramp Rep Freq 100,000 Hz 000 mV
Waveform
Repetition Frequency
Positive Only
Pulse Generator Mode
Duty Cycle
Using WAVELOAD.EXE
Downloading arbitrary waveforms
Saving Arbitrary Waveforms
Cwaveload /COMx /y /baudz filename.ext
Using your own program
Floating Point Format
Data Formats
Rules for Floating Point format
Time & Value Floating Point Format
Example #2
Digital Format
Integer Format
Rules for Integer format
Rules for Hexadecimal format
Hexadecimal Format
Example The data value E468 is handled as follows
Rules for Binary format
Binary Format
Example
Arb
Multiple Units Locking
Generator
More on Phase Offsets
Phase Resolution
Starting Address = Number of waveform points * Phase Offset
Waveform Size Restrictions
Example Arb Program
Program Listing ARB.BAS
Close System
Subroutines
Return
Print #1, a Send integer value to
Return
Return
Wiring Diagram
DC Operation Option
4071 Specifications
Operating Modes
Software CD
Remote
Hardware Setup
Appendix a
CLS
CLS Print Print
Subroutines
END SUB
Television Remote Control Example
Appendix B
CLS
Make sure a 4071 is attached to the serial port
Print
Limited Two-Year Warranty
Service Information
Savi Ranch Pkwy Yorba Linda, CA 92887 USA TEL