' | Program Start |
|
| ||
| ||
DECLARE SUB Delay (X%) | ' Declare functions used below. | |
|
| ' (The Delay function waits x mS then returns) |
DECLARE SUB Pause () | ' (The Pause fctn waits for a keypress then returns) | |
DIM Array(5) | ' General purpose array | |
' | User Entered Values |
'By observing the signal from a remote control with an oscilloscope, the following
'parameters were recorded. To adapt this program to another remote control model, change
'the values below:
CarrierFreq$ = "32768" ' Type in the infrared carrier freq here. ' this value is in Hz
OnTime$ = "30"' Type in the burst on time here.
' this value is in mS
OffTime$ = "10"' Type in the burst off time here.
'this value is in mS
'These variables hold the number of pulses that form each command:
PowerToggle = 20 | ' Turn the TV on and off (twenty pulses) |
ChannelUp = 9 | ' Go to next channel |
ChannelDown = 12 | ' Go to previous channel |
VolumeUp = 3 | ' Increase volume one notch |
VolumeDown = 5 | ' Decrease volume one notch |
CLS | ' Clear the screen |
'This array is used as a data table which, given a command menu number as an index,
'returns the number of pulses in a given infrared pulse stream.
Array(1) = PowerToggle
Array(2) = ChannelUp
Array(3) = ChannelDown
Array(4) = VolumeUp
Array(5) = VolumeDown
'Open serial port 1 for communication with the 4071 with these parameters:
'Ignore the CD,CTS,DCD flow control lines
'Set a 5 sec maximum
'Set the receive buffer to 2K bytes
'Disable the RTS flow control line
'Set the transmit buffer to 1K bytes
'File access type is Random
'Set random access buffer size to 2K
OPEN "COM1:9600,n,8,1,CD0,CS0,DS0,OP5000,RB2048,RS,TB1024" FOR RANDOM AS #1 LEN = 2048
78
BK Precision 4071 User Manual Rev.2.2