Briggs & Stratton 030210-2 manual Generator Storage, Engine Storage, Other Storage Tips

Page 16

8000W Portable Generator

STORAGE

The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than

30 days, use the following guidelines to prepare it for storage.

Generator Storage

Clean the generator as outlined in “Generator Cleaning”.

Check that cooling air slots and openings on generator are open and unobstructed.

WARNING

Storage covers can be flammable.

DO NOT place a storage cover over a hot generator.

Let equipment cool for a sufficient time before placing the cover on the equipment.

Engine Storage

See engine operator’s manual for instructions.

Other Storage Tips

To prevent gum from forming in fuel system or on essential carburetor parts, add fuel stabilizer into fuel tank and fill with fresh fuel. Run the unit for several minutes to circulate the additive through the carburetor. The unit and fuel can then be stored for up to

24 months. Fuel stabilizer can be purchased locally.

DO NOT store fuel from one season to another unless it has been treated as described above.

Replace fuel container if it starts to rust. Rust and/or dirt in fuel can cause problems if it's used with this unit.

Store unit in a clean and dry area.

16

Image 16
Contents Operator’s Manual Manual del Operario Call Generator Helpline Llame Línea Directa del GeneradorSafety Rules Table of ContentsEquipment Description When Adding or Draining Fuel When Starting EquipmentWhen Operating Equipment When Transporting or Repairing EquipmentWhen Adjusting or Making Repairs to Your Generator When Testing for Engine SparkKnow Your Generator Assembly Carton ContentsCheck Battery / Attach Negative Battery Wire Electric StartInstall Wheel Kit Refer to and install the wheel kit as followsWhen Adding Fuel Before Starting the EngineAdd Fuel Add Engine OilUsing the Generator Connecting to a Building’s Electrical SystemSystem Ground Generator LocationConnecting Electrical Loads Operating GeneratorStarting the Engine Do not Overload the GENERATOR. See Don’t Overload GeneratorReceptacles Stopping the Engine120/240 Volt AC, 30 Amp, Locking Receptacle Volt AC, 20 Amp, Duplex ReceptaclesBattery Charger Cold Weather OperationCreating a Temporary Shelter Creating a Permanent ShelterPower Management Dont Overload GeneratorCapacity ExampleSpecifications General Maintenance RecommendationsStorage Generator StorageEngine Storage Other Storage TipsTroubleshooting Problem Cause Correction8000W Portable Generator Limited Warranty Tabla DE Contenidos Descripción DEL EquipoReglas DE Seguridad AdvertenciaCuando Añada Combustible O Vacíe EL Depósito Cuando Ponga EN Funcionamiento EL EquipoCuando Opere EL Equipo Cuando Transporte O Repare EL EquipoCuando Ajuste O Haga Reparaciones a SU Generador PrecauciónCuando Pruebe LA Bujía DEL Motor Conozca SU Generador Tapa del Depósito del Aceite Llene el motor con aceite aquíMontaje Arranque EléctricoPara Retirar el Generador de la Caja Contenido de la CajaInstale el Juego de Ruedas Instale el Juego de Ruedas Como Sigue FiguraAntes DE Darle Arranque AL Motor Agregar Aceite al MotorAgregue Combustible Cuando Añada CombustibleUSO DEL Generador Tierra del SistemaUbicación del Generador Conexión al Sistema Eléctrico de un EdificioOperando EL Generador Encienda el MotorConexion De Cargas Electricas No Sobrecargue EL GENERADOR.Vea No Sobrecargue GeneradorReceptáculos Precaución Parado Del MotorVolt AC, 20 Amp, Receptáculos Dobles 120/240 Voltios AC, 30 Amp, Receptáculo de SeguridadCargador DE Batería Operación Durante UN Clima FríoCreación de una Estructura de Protección Provisional Creación de una Estructura de Protección PermanenteNo Sobrecargue Generador CapacidadControl de la Energía EjemploEspecificaciones Recomendaciones Generales DE MantenimientoAlmacenamiento Almacenando el GeneradorAlmacenando el Motor Otras Sugerencias Para el AlmacenandoProblemo Accion Causa Diagnositicos DE AveríasGarantía Limitada