Briggs & Stratton 30217 Before Starting, Add Fuel, Add Engine Oil, When Adding Fuel

Page 7

5250W Portable Generator

2.Slide axle through both axle mounting brackets on cradle frame, as shown in Figure 1.

3.Slide a wheel over the axle.

NOTE: Be sure to install wheel with raised hub inboard.

4.Slide a flat washer over the axle and place the e-ring onto the groove in the axle.

5.Place one end of the needle nose pliers on the bottom of the axle and the other end of the pliers on top of the e-ring. Seat the e-ring by pressing the pliers closed.

6.Repeat step 3 through 5 to secure second wheel.

7.Remove the temporary blocks.

8.Attach support leg using two 1/2” or 13mm wrenches with 20mm cap screws and lock nuts.

9.Center lifting handle on generator end of cradle. Attach handle using two 1/2” or 13mm wrenches with 45mm capscrews and hex nuts.

BEFORE STARTING THE

Add Fuel

NOTE: This gasoline engine is certified to operate on

gasoline. Exhaust Emission Control System: EM (Engine Modifications).

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

ENGINE

Add Engine Oil

• Place generator on a level surface.

CAUTION

Any attempt to crank or start the engine before it has been properly filled with the recommended oil will result in equipment failure.

Refer to engine manual for oil fill information.

Damage to equipment resulting from failure to follow this instruction will void warranty.

Refer to engine owner’s manual and follow oil recommendations and instructions.

NOTE: Check oil often during engine break–in. Refer to engine owner’s manual for recommendations.

1.Use clean, fresh, regular UNLEADED fuel with a minimum of 85 octane. DO NOT use fuel which contains Methanol. DO NOT mix oil with fuel.

2.Clean area around fuel fill cap, remove cap.

3.Slowly add regular unleaded fuel to fuel tank. Be careful not to overfill. Allow about 1.5" of tank space for fuel expansion (Figure 2).

Figure 2 - Fuel Expansion

 

AirSpace

Tank

 

 

 

Fuel

 

1.5”

 

 

 

 

4.

Install fuel cap and wipe up any spilled fuel.

 

NOTE: The generator assembly rotates on a prelubricated and sealed ball bearing that requires no additional lubrication for the life of the bearing.

7

Image 7
Contents Model / Modelo 030217 5250W Safety Rules Table of ContentsEquipment Description When Transporting or Repairing Equipment When Adding or Draining FuelWhen Starting Equipment When Operating EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorVolt AC, 20 Amp, Duplex Receptacle May be Know Your Generator120/240 Volt AC, 30 Amp Locking Receptacle May Remove Generator From Carton AssemblyInstall Wheel KIT Carton ContentsAdd Fuel When Adding FuelBefore Starting EngineGenerator Location Using the GeneratorConnecting to a Building’s Electrical System System GroundStopping the Engine Connecting Electrical LoadsOperating Generator Starting the Engine120/240 Volt AC, 30 Amp, Locking Receptacle ReceptaclesVolt AC, 20 Amp, Duplex Receptacle Example Power ManagementDont Overload Generator CapacityEngine Maintenance SpecificationsGeneral Maintenance Recommendations Generator MaintenanceGenerator Storage StorageEngine Storage Other Storage Tips Problem Cause Correction TroubleshootingLimited Warranty Advertencia Tabla DE ContenidosDescripción DEL Equipo Instrucciones DE SeguridadCuando Transporte O Repare EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoCuando Ajuste O Haga Reparaciones a SU Generador PrecauciónCuando Pruebe LA Bujía DEL Motor Conozca SU Generador Contenido De La Caja MontajeInstale EL Juego DE Ruedas Para Retirar el Generador de la CajaCuando Añada Combustible Antes DE Darle Arranque AL MotorAgregar Aceite al Motor Agregue CombustibleConexión al Sistema Eléctrico de un Edificio USO DEL GeneradorTierra del Sistema Ubicación del GeneradorParado Del Motor Operando EL Generador PrecauciónEncienda el Motor Conexion De Cargas Electricas120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Receptáculos PrecauciónVolt AC, 20 Amp, Receptáculo Dobles Ejemplo No Sobrecargue GeneradorCapacidad Control de la EnergíaMantenimiento del Generador EspecificacionesRecomendaciones Generales DE Mantenimiento Mantenimiento del MotorAlmacenando el Motor Diagnositicos DE AveríasAlmacenamiento Almacenando el GeneradorGarantía Limitada