Briggs & Stratton 30217 Know Your Generator, Volt AC, 20 Amp, Duplex Receptacle May be

Page 5

5250W Portable Generator

KNOW YOUR GENERATOR

Read this owner’s manual and safety rules before operating your generator.

Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.

Recoil Starter

Rocker Switch

 

(on engine shroud)

Fuel Tank

 

Choke Lever

Circuit

Breakers (AC)

Air Cleaner

 

120/240 Volt AC,

Spark Arrester Muffler

30 Amp Receptacle

 

 

Oil Fill

120 Volt AC, 20 Amp

 

Duplex Receptacle

Grounding Fastener

120 Volt AC, 20 Amp, Duplex Receptacle — May be

Circuit Breakers (AC) — Push-to-reset circuit breakers

used to supply electrical power for the operation of

are provided to protect the generator against electrical

120 Volt AC, 20 Amp, single phase, 60 Hz electrical, lighting,

overload.

appliance, tool and motor loads.

Fuel Tank — Capacity of seven (7) U.S. gallons.

120/240 Volt AC, 30 Amp Locking Receptacle — May

Grounding Fastener — If required, please consult a

be used to supply electrical power for the operation of

qualified electrician, electrical inspector, or local agency

120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz

having jurisdiction.

electrical, lighting, appliance, tool and motor loads.

Oil Fill — Add engine oil here.

Air Cleaner — Protects engine by filtering dust and debris

Recoil starter — Used to start the engine.

out of intake air.

Rocker Switch — Set this switch to "On" before using

Choke Lever — Used when starting a cold engine.

recoil starter. Set switch to "Off" to switch off engine.

 

Spark Arrester Muffler — Exhaust muffler lowers

 

engine noise and is equipped with a spark arrester screen.

 

5

Image 5
Contents Model / Modelo 030217 5250W Equipment Description Table of ContentsSafety Rules When Starting Equipment When Adding or Draining FuelWhen Operating Equipment When Transporting or Repairing EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your Generator120/240 Volt AC, 30 Amp Locking Receptacle May Know Your GeneratorVolt AC, 20 Amp, Duplex Receptacle May be Install Wheel KIT AssemblyCarton Contents Remove Generator From CartonBefore Starting When Adding FuelEngine Add FuelConnecting to a Building’s Electrical System Using the GeneratorSystem Ground Generator LocationOperating Generator Connecting Electrical LoadsStarting the Engine Stopping the EngineVolt AC, 20 Amp, Duplex Receptacle Receptacles120/240 Volt AC, 30 Amp, Locking Receptacle Dont Overload Generator Power ManagementCapacity ExampleGeneral Maintenance Recommendations SpecificationsGenerator Maintenance Engine MaintenanceEngine Storage Other Storage Tips StorageGenerator Storage Problem Cause Correction TroubleshootingLimited Warranty Descripción DEL Equipo Tabla DE ContenidosInstrucciones DE Seguridad AdvertenciaCuando Ponga EN Funcionamiento EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Opere EL Equipo Cuando Transporte O Repare EL EquipoCuando Pruebe LA Bujía DEL Motor PrecauciónCuando Ajuste O Haga Reparaciones a SU Generador Conozca SU Generador Instale EL Juego DE Ruedas MontajePara Retirar el Generador de la Caja Contenido De La CajaAgregar Aceite al Motor Antes DE Darle Arranque AL MotorAgregue Combustible Cuando Añada CombustibleTierra del Sistema USO DEL GeneradorUbicación del Generador Conexión al Sistema Eléctrico de un EdificioEncienda el Motor Operando EL Generador PrecauciónConexion De Cargas Electricas Parado Del MotorVolt AC, 20 Amp, Receptáculo Dobles Receptáculos Precaución120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Capacidad No Sobrecargue GeneradorControl de la Energía EjemploRecomendaciones Generales DE Mantenimiento EspecificacionesMantenimiento del Motor Mantenimiento del GeneradorAlmacenamiento Diagnositicos DE AveríasAlmacenando el Generador Almacenando el MotorGarantía Limitada