Briggs & Stratton 30211 operating instructions Specifications, General Maintenance Recommendations

Page 13

6200W Portable Generator

SPECIFICATIONS

Starting Wattage . . . . . . . . . . . . . . . . . . . . . . .8,700 watts Wattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6,200 watts AC Load Current:

At 120 Volts . . . . . . . . . . . . . . . . . . . . . . . . .51.6 Amps At 240 Volts . . . . . . . . . . . . . . . . . . . . . . . . .25.8 Amps Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . .60 Hertz Fuel Tank Capacity . . . . . . . . . . . . . . . . . . . . 7 U.S. gallons Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . . 198 lbs.

GENERAL MAINTENANCE RECOMMENDATIONS

The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. NEVER operate a

damaged or defective generator.

NOTE: Should you have questions about replacing components on your Briggs & Stratton Power Products generator, please call 1-800-743-4115for assistance.

Engine Maintenance

See engine operator’s manual for instructions.

CAUTION

Avoid prolonged or repeated skin contact with used motor oil.

Used motor oil has been shown to cause skin cancer in certain laboratory animals.

Thoroughly wash exposed areas with soap and water.

KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS.

NOTE: DO NOT use a garden hose to clean generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and stator winding insulation.Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

Battery Maintenance

Other than float charging, described elsewhere, no maintenance is required for the starting battery. Keep the battery and terminals clean and dry.

IMPORTANT: Battery charging should be performed in a dry location, such as inside a garage.

Generator Cleaning

• Use a damp cloth to wipe exterior surfaces clean.

CAUTION

Improper treatment of generator can damage it and shorten its life.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

Generator Maintenance

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves or any other foreign material.

Use a soft bristle brush to loosen caked on dirt or oil.

Use a vacuum cleaner to pick up loose dirt and debris.

Use low pressure air (not to exceed 25 psi) to blow away dirt. Inspect cooling air slots and opening on generator.These openings must be kept clean and unobstructed.

13

Image 13
Contents 030211 6200W Safety Rules Table of ContentsEquipment Description When Starting Equipment When Adding or Draining FuelWhen Operating Equipment When Transporting or Repairing EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorKnow Your Generator Carton Contents AssemblyCheck Battery / Attach Negative Battery Wire Electric StartRefer to and install the wheel kit as follows Install Wheel KitBefore Starting the Engine When Adding FuelAdd Fuel Add Engine OilConnecting to a Building’s Electrical System Using the GeneratorSystem Ground Generator LocationOperating Generator Connecting Electrical LoadsStarting the Engine Do not Overload the GENERATOR. See Don’t Overload GeneratorReceptacles Battery ChargerStopping the Engine 120/240 Volt AC, 30 Amp, Locking ReceptacleDont Overload Generator Power ManagementCapacity ExampleGeneral Maintenance Recommendations SpecificationsGenerator Storage StorageEngine Storage Other Storage TipsProblem Cause Correction Troubleshooting6200W Portable Generator Limited Warranty Tabla DE Contenidos Conserve Estas InstruccionesDescripción DEL Equipo Reglas DE SeguridadCuando Ponga EN Funcionamiento EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Opere EL Equipo Cuando Transporte O Repare EL EquipoCuando Ajuste O Haga Reparaciones a SU Generador PrecauciónCuando Pruebe LA Bujía DEL Motor Conozca SU Generador Arranque Eléctrico MontajeDesembalaje del Generador Contenido de la CajaInstale el Juego de Ruedas Como Sigue Figura Instale el Juego de RuedasAgregar Aceite al Motor Antes DE Darle Arranque AL MotorAgregue Combustible Cuando Añada CombustibleTierra del Sistema USO DEL GeneradorConexión al Sistema Eléctrico de un Edificio Ubicación del GeneradorEncienda el Motor Operando EL GeneradorConexion De Cargas Electricas No Sobrecargue EL GENERADOR.Vea No Sobrecargue GeneradorCargador DE Batería Receptáculos PrecauciónParado Del Motor Volt AC, 20 Amp, Receptáculos DoblesCapacidad No Sobrecargue GeneradorControl de la Energía EjemploRecomendaciones Generales DE Mantenimiento EspecificacionesAlmacenando el Generador AlmacenamientoAlmacenando el Motor Otras Sugerencias Para el AlmacenandoDiagnositicos DE Averías Problemo Accion CausaGarantía Limitada