Baldor 3KW-9KW manual Engine Information

Page 10

ENGINE INFORMATION

This operator's manual only covers basic day-to-day engine operating instructions. However, the engine manufacturer's manual is included with your generator set and should be referred to for any additional information you may need. Become familiar with and follow all the engine manufacturer's operation, safety and maintenance guidelines.

OIL: Use a high quality oil of the type specified in the engine owner's manual for your specific operating conditions. Check the oil regularly, or at minimum every 5-8 hours of operation.

TO HELP PREVENT ENGINE DAMAGE, CHECK THE OIL LEVEL OF THE ENGINE

REGULARLY AND MAKE SURE IT IS MAINTAINED AT THE PROPER LEVEL.

FUEL: (Gasoline or Diesel): Fill the fuel tank prior to operation. Use a clean fuel of the

type and specification mentioned in the engine owner's manual. Do not mix oil with the fuel. Never fuel the engine while it is running or hot as any spilled fuel may ignite on the hot surfaces. Always shut the engine off and allow it to cool down before refueling it.

SPILLED FUEL MAY IGNITE AND CAUSE PROPERTY DAMAGE, SEVERE

INJURY OR EVEN DEATH IF IT WOULD COME INTO CONTACT WITH ANY

HOT SURFACE. NEVER REFUEL AN ENGINE WHILE IT IS HOT OR RUNNING.

ALWAYS CLEAN UP ANY SPILLED FUEL AND ALLOW IT TO DRY PRIOR TO

STARTING AN ENGINE.

FUEL (L.P. or Natural Gas): Make sure the gaseous fuel being supplied to the unit is in vapor form and that it is being delivered to the engine's gaseous fuel regulator at the pressure specified on it. An engine needs 10,000 BTU's of fuel per each engine horsepower to operate properly.

GASEOUS FUEL IS EXTREMELY FLAMMABLE AND CAN CAUSE PROPERTY

DAMAGE, SEVERE INJURY OR DEATH. CHECK THE GASEOUS FUEL SUPPLY

SYSTEM ON A MONTHLY BASIS FOR LEAKS. HAVE ANY LEAKS REPAIRED

BY AN EXPERIENCED PROFESSIONAL PRIOR TO STARTING YOUR

GENERATOR SET.

OPERATING SPEED: This generator set must be run at it's proper speed in order to obtain the electrical power it was built to produce.

All engines have a tendency to slow down when a load is applied to it. The governor on the engine is designed to hold the operating speed as nearly constant as possible. When the load connected to the generator set is increased, the engine is more heavily loaded and as a result the engine speed drops slightly. This slight decrease in engine speed results in a slight decrease in generator voltage and frequency output. This voltage and frequency variation has no appreciable effect in the operation of motors, lights, and most appliances and tools. However, timing devices and clocks will not keep perfect time when used on this generator.

- 3 -

Image 10
Contents OHV Series 3KW-9KW Forward Page Iii For Gasoline or Diesel Powered Generator Sets Page Table of Contents Location Connections Engine Information Maintenance Generator END MaintenanceEngine Maintenance Storage USE of Electric Motors Service Ordering PartsOperation Prior to Starting the UnitOIL Capacities and Battery Recommendations Simple Troubleshooting No OutputLOW Voltage Output Control Panel For OHV40, OHV50, OHV60 Control Panel Generator-End Componentry Parts Breakdown Generator-End Componentry For OHV40, OHV50, OHV60 Generator Sets OHV85 For OHV85 Generator Sets REF Letter OLD NEW Description OHV30 OHV40, OHV50, OHV60 OHV85E Page Generator Series Owner’s Responsibilities California Proposition 65 Warning Oregon Street Oshkosh WI Phone 920 236-4200 Fax 920