Baldor 3KW-9KW manual Operation, Prior to Starting the Unit

Page 16

OPERATION

PRIOR TO STARTING THE UNIT:

1.Locate and set up the generator set in an open, dry, well ventilated and reasonably level location.

OPERATING THIS UNIT IN AN AREA NOT SUITABLE FOR IT'S PROPER USE MAY CAUSE DAMAGE TO THE UNIT, SEVERE INJURY, OR DEATH. SEE "LOCATION INFORMATION" SECTION LOCATED ELSEWHERE IN THIS MANUAL.

2.If grounding is required for your application, check to make sure your unit is grounded properly.

3.Check the engine's oil level and add whatever amount of oil is necessary to bring it up to the level that is recommended by the engine manufacturer.

4.Check the engine's fuel level and add if necessary.

NEVER REFUEL THE GENERATOR SET WHEN IT IS HOT OR RUNNING.

5.Open the fuel valve on the fuel tank.

6.If the engine is equipped with a fuel valve, open it at this time.

7.Check the fuel system for fuel leaks and repair them prior to starting the engine.

WIPE UP ANY SPILLED FUEL AND ALLOW IT TO DRY PRIOR TO

STARTING THE ENGINE.

8.Disconnect or "turn Off" all external loads.

9.Make sure all circuit breakers are set (pushed in).

STARTING THE GEN SET:

1.Move the engine's choke lever to the 'Choke/Start" position. If the engine is warm or if the ambient air temperature is high, try starting the engine without choking it.

2.Starting with recoil:

A.If the generator's control panel has an engine 'ON/OFF' switch on it, turn it on at this time.

B.If the engine has an 'ON/OFF' switch on it, turn it on at this time.

C.Pull lightly on the recoil grip until you feel significant resistance, then pull sharply. Do not Allow the recoil rope to 'snap back' into the recoil housing. Allow the recoil to gently rewind into the recoil housing. See your engine manual for instructions specific to your unit.

-9 -

Image 16
Contents OHV Series 3KW-9KW Forward Page Iii For Gasoline or Diesel Powered Generator Sets Page Table of Contents Location Connections Engine Information Maintenance Generator END MaintenanceEngine Maintenance Storage USE of Electric Motors Service Ordering PartsOperation Prior to Starting the UnitOIL Capacities and Battery Recommendations Simple Troubleshooting No OutputLOW Voltage Output Control Panel For OHV40, OHV50, OHV60 Control Panel Generator-End Componentry Parts Breakdown Generator-End Componentry For OHV40, OHV50, OHV60 Generator Sets OHV85 For OHV85 Generator Sets REF Letter OLD NEW Description OHV30 OHV40, OHV50, OHV60 OHV85E Page Generator Series Owner’s Responsibilities California Proposition 65 Warning Oregon Street Oshkosh WI Phone 920 236-4200 Fax 920