LOCATION

For best service from your stationary generator set there are several factors which should be taken into consideration when choosing the best location in which to permanently mount it:

MOISTURE: All electrical equipment should be protected from excessive moisture. Failure to do so will result in deterioration of the insulation and may result in short circuits and a possible electrocution hazard.

OPERATING ELECTRICAL EQUIPMENT IN WET ENVIRONMENTAL

CONDITIONS CREATE A POTENTIAL ELECTROCUTION HAZARD.

DO NOT OPERATE ELECTRICAL EQUIPMENT WHILE STANDING IN

WATER, ON WET GROUND, OR WITH WET HANDS OR SHOES.

DIRT: Foreign materials such as dust, sand and other abrasive materials have a tendency to cause excessive wear to both engine and generator parts. It is important that the unit be operated in a reasonably clean environment.

HEAT: All engines give off considerable heat when running. Since the engine and your generator set uses air to keep it cool it is important that the temperature of the area in which it is located is does not exceed 100o F (even while it is running). Where natural ventilation is inadequate a fan to boost circulation should be utilized.

EXHAUST: Exhaust Gases from internal combustion engines are extremely poisonous. Whenever an engine is run indoors the exhaust fumes must be vented to the outside.

EXHAUST FUMES CAN CAUSE SEVERE INJURY OR DEATH. ALWAYS

OPERATE IN A WELL-VENTILATED AREA.

CONFINED SPACE: This unit must not be operated in a confined space or an enclosed compartment

/area. Running the generator set in this environment is a potential fire hazard and is not authorized. Engine and generator overheating damage could also occur due to restricted cooling airflow to and from the unit.

OPERATING THIS UNIT IN AN AREA WITHOUT ADEQUATE

VENTILATION CREATES A POTENTIAL FIRE HAZARD. ALWAYS

OPERATE THIS UNIT IN A WELL-VENTILATED AREA.

- 1 -

Image 8
Contents OHV Series 3KW-9KW Forward Page Iii For Gasoline or Diesel Powered Generator Sets Page Table of Contents Location Connections Engine Information Maintenance Generator END MaintenanceEngine Maintenance Storage USE of Electric Motors Service Ordering PartsOperation Prior to Starting the UnitOIL Capacities and Battery Recommendations Simple Troubleshooting No OutputLOW Voltage Output Control Panel For OHV40, OHV50, OHV60 Control Panel Generator-End Componentry Parts Breakdown Generator-End Componentry For OHV40, OHV50, OHV60 Generator Sets OHV85 For OHV85 Generator Sets REF Letter OLD NEW Description OHV30 OHV40, OHV50, OHV60 OHV85E Page Generator Series Owner’s Responsibilities California Proposition 65 Warning Oregon Street Oshkosh WI Phone 920 236-4200 Fax 920