CONTROL PANEL

FOR OHV85

A = THE AUTO IDLER FEATURE ON/OFF SWITCH. The Auto Idler Feature allows the engine on the generator set to slow down to a "slow speed position" when there is no load being applied to the unit. When a load is applied to the unit the auto idler circuitry allows the engine to speed up and operate at the engine governor's preset speed. When this switch is turned off, the engine will continuously run at the preset speed of the engine governor.

B = ELAPSED TIME METER. This meter keeps and displays a continuous running total of the hours accumulated on the unit.

C = VOLTMETER. This voltmeter displays the voltage level being produced by the generator set.

D = AC CIRCUIT BREAKERS. These Circuit Breakers provide overload protection for the generator set. When tripped, the circuit breaker plungers will extend approximately 3/8".

E = NEMA L530R RECEPTACLE. This is a twist-lock style receptacle rated for 125VAC, 30 Amps.

F = NEMA 515R GFCI DUPLEX. This ground fault circuit interrupter duplex is rated at 125VAC, 20 Amps. This receptacle must be tested on a regular basis (Monthly).

G = NEMA L14-30R RECEPTACLE. This is a twist-lock style receptacle rated for 120/240 VAC,

depending on how the mating plug is wired. It is capable of carrying 30 Amps.

- 15 -

Image 22
Contents OHV Series 3KW-9KW Forward Page Iii For Gasoline or Diesel Powered Generator Sets Page Table of Contents Location Connections Engine Information Maintenance Generator END MaintenanceEngine Maintenance Storage USE of Electric Motors Service Ordering PartsOperation Prior to Starting the UnitOIL Capacities and Battery Recommendations Simple Troubleshooting No Output LOW Voltage Output Control Panel For OHV40, OHV50, OHV60 Control Panel Generator-End Componentry Parts Breakdown Generator-End Componentry For OHV40, OHV50, OHV60 Generator Sets OHV85 For OHV85 Generator Sets REF Letter OLD NEW Description OHV30 OHV40, OHV50, OHV60 OHV85E Page Generator Series Owner’s Responsibilities California Proposition 65 Warning Oregon Street Oshkosh WI Phone 920 236-4200 Fax 920