Problem | Possible Cause(s) Solution | |||
|
|
|
|
|
Engine fails to start | 1. | Fuel tank empty, or stale fuel | 1. | Fill tank with clean fresh gasoline. |
| 2. | Improper fuel mixture | 2. | Mix new fuel at a ratio of 50:1 |
| 3. | Blocked fuel line | 3. | Clean fuel line |
| 4. | Key not in ON position | 4. | Insert key and turn to ON position |
| 5. | Spark plug wire disconnected | 5. | Connect wire to spark plug. |
| 6. | Faulty spark plug | 6. | Clean spark plug, readjust gap, or |
|
|
|
| replace. |
| 7. | Engine not primed | 7. | Prime engine four times. |
| 8. | Engine flooded from excessive | 8. | Wait at least ten minutes before |
|
| priming |
| starting. |
|
|
|
|
|
Engine runs erratic | 1. | Unit running on choke | 1. | Move choke lever to OFF position. |
| 2. | Fuel line blocked, or stale fuel | 2. | Clean fuel line and fill tank with |
|
|
|
| fresh, clean gasoline. |
| 3. | Water or dirt in fuel system | 3. | Refer to engine manual for remedy. |
| 4. | Carburetor out of adjustment | 4. | Refer to engine manual for remedy. |
|
|
|
|
|
Engine overheats | 1. | Carburetor out of adjustment | 1. | Refer to engine manual for instruc- |
|
|
|
| tion. |
Loss of power | 1. | Spark plug wire loose | 1. | Firmly connect spark plug wire. |
| 2. | Vent in gas cap plugged | 2. | Clear vent. |
|
|
|
|
|
Excessive vibration | 1. | Loose parts or damaged auger | 1. | Stop engine immediately and |
|
|
|
| disconnect spark plug wire. Check |
|
|
|
| for possible damage. Tighten all |
|
|
|
| bolts and nuts. Repair as needed. If |
|
|
|
| the problem persists, take unit to an |
|
|
|
| authorized service dealer. |
|
|
|
|
|
Unit fails to | 1. | Drive cable out of adjustment | 1. | Adjust auger control cable as shown |
|
|
|
| in Adjustments section. |
| 2. Drive belt loose or damaged | 2. | Replace drive belt. | |
|
|
|
|
|
Augers continue to rotate | 1. | Cable out of adjustment. | 1. | Adjust auger control cable as |
|
|
|
| shown in Adjustments section. |
Unit fails to discharge | 1. | Chute assembly clogged. | 1. | Stop engine and disconnect spark |
snow |
|
|
| plug wire. Clean chute and inside |
|
|
| of auger housing with | |
|
|
|
| |
|
|
|
| tool or stick. |
| 2. | Shear pin sheared. | 2. | Replace shear pin. |
| 3. Foreign object lodged in auger. | 3. | Stop engine immediately and | |
|
|
|
| disconnect the spark plug wire. |
|
|
|
| Remove object from auger. |
| 4. Auger control cable out of | 4. | Adjust auger control cable. | |
|
|
| ||
|
| adjustment. | 5. | Replace auger belt. |
| 5. Auger belt loose or damaged. | |||
|
|
|
8
Trouble-
Shooting
Please do NOT
return the unit to the
retailer from which it was purchased, without first contacting Customer Support.