iOptron IEQ45TM instruction manual Balance the mount in DEC axis

Page 15

Balance the mount in DEC axis

Release the four (4) R.A. Clutch Screws and rotate the R.A. axis to place the DEC axis in the horizontal position, as shown in Figure 16(a), and then tighten the R. A. Clutch Screws. The OTA can be on either side. Then release the DEC Clutch Handle and rotate the OTA to a horizontal position as shown in Figure 16(b). If the OTA has a tendency to rotate about the DEC axis, you will have to slide the OTA forward or backward to balance it in the horizontal position about the DEC axis. When the OTA is balanced horizontally, tighten the DEC Handle.

Balance the mount in R.A. axis

Release the four (4) R.A. Clutch Screws. If the DEC axis stays in the horizontal position, as shown in Figure 16(a), it means the R.A. axis is balanced. Otherwise, release the CW Locking Screw and move the CW as required to balance the R.A. axis. Tighten the CW Locking Screw.

(a)

(b)

Figure 16

Adjust the mount to Zero Position

After polar alignment, adjust the mount at Zero Position. The Zero Position is the position with the CW shaft pointing toward the ground, OTA at the highest position with its axis parallel to the polar axis and the OTA pointing to the NCP, as shown in Figure 17. Loosen the DEC Clutch Handle on the DEC axis and the four (4) R.A. Clutch Screws on the R.A. axis to adjust the mount to the Zero Position. Tighten the screws after each adjustment. Remember, the hand controller needs to be at the Zero Position as well! The simplest way is turn the mount power OFF and ON again to reset the hand controller.

15

Image 15
Contents SmartStar iEQ45TM Table of Content Ioptron TWO Year TELESCOPE, MOUNT, and Controller Warranty IEQ45TM Overview FeaturesParts List IEQ45TM AssemblyAlignment Peg Tripod Spreader Tripod Leg Leg Lock Screw Assembly TermsIntroduction IEQ45 PortsIEQ45 Assembly Set Latitude Adjustment Knob Attach the iEQ45 Mount Attach Dovetail Adapter Polar axis adjustments Quick polar axis alignment Install Counterweights Balance the mount in DEC axis Zero position Key Description Go2NovaTM 8407 Hand ControllerPEC LCD ScreenPage Getting Started Setup the Mount and Polar AlignmentSetting Up the Hand Controller Set Up Time and SiteLocal Time Set Star Identifying Function Turn Off the MountInitial Star Alignment Go to the Moon and Other StarsPage Slew to an Object Complete Functions of Go2NovaTM Hand ControllerSet Up Controller Sync to TargetElectric Focuser Meridian Treatment Set Anti-backlashAlign Disp R.A Axis Error Three Star AlignmentTest Backlash Record PEC PEC OptionPole Star Position PEC PlaybackSet Tracking Rate Set User ObjectsSystem Self-Test Set Guider Rate Guide OptionsSet Slewing Rate Park ScopeBalance Test To Zero PositionBattery Replacement and Disposal Instructions Maintenance and ServicingMaintenance IOptron Customer ServiceGPS Appendix A. Technical SpecificationsAppendix B. Go2NovaTM 8407 HC Menu Structure Page Appendix C. Firmware Upgrade Appendix D. Computer Control an iEQ45 Mount Messier Catalog Appendix E. Go2NovaTM Star ListNamed Star List Modern Constellations Deep Sky Object List Double Star List SAO Atik Ioptron TWO Year TELESCOPE, MOUNT, and Controller Warranty