5.12. To Zero Position

This moves your telescope to its Zero Position (refer to Figure 17). When the power is turned on, the mount assumes the Zero Position. This is its reference point for all other objects being tracked.

5.13. Balance Test

This function provides a visual indication and assistance balancing both the R.A. and DEC axes. Before performing the balance test, make sure the correct latitude is set according to the instructions in Section 2.5, Step 4. Turn the mount on and make sure the telescope is in the Zero Position.

Press the MENU button, scroll down to “Balance Test”, and press ENTER. The mount will start to slew and stop at the balance position. You can select either “DEC Balance Test” or “RA. Balance Test.”

Select “RA Balance Test” and press ENTER to start the test. After few swings, a test results will be displayed on the hand controller LCD screen (Figure 22 (a)):

<==

< . Balance OK! >

(a)

(b)

Figure 22. (a) R.A. and (b) DEC Balance Test

Follow the arrow indicator to move the CW left or right. There are six balance test indicators in each direction:

<Balance OK! >: The R.A. is balanced;

<. Balance OK! > or < Balance OK! . >: The R.A. is almost balanced; a minor adjustment may be done;

<.. Balance OK! > or < Balance OK! .. >: The mount balance is OK for observation; a small adjustment may be done;

<= or =>: Move counterweight left or right;

<== or ==>: Move counterweight left or right more;

<=== or ===>: The R.A. axis is off balance. Move counterweight according to the arrow left or right.

Press the ENTER key to test it again, until the < Balance OK!> indicator is displayed.

Press BACK button and select “DEC Balance Test”. Move the telescope back and forth to balance the OTA around the DEC axis until < Balance OK! > is displayed.

32

Image 32
Contents SmartStar iEQ45TM Table of Content Ioptron TWO Year TELESCOPE, MOUNT, and Controller Warranty Features IEQ45TM OverviewIEQ45TM Assembly Parts ListAssembly Terms Alignment Peg Tripod Spreader Tripod Leg Leg Lock ScrewIEQ45 Ports IntroductionIEQ45 Assembly Set Latitude Adjustment Knob Attach the iEQ45 Mount Attach Dovetail Adapter Polar axis adjustments Quick polar axis alignment Install Counterweights Balance the mount in DEC axis Zero position Go2NovaTM 8407 Hand Controller Key DescriptionLCD Screen PECPage Setup the Mount and Polar Alignment Setting Up the Hand ControllerSet Up Time and Site Getting StartedLocal Time Set Turn Off the Mount Initial Star AlignmentGo to the Moon and Other Stars Star Identifying FunctionPage Complete Functions of Go2NovaTM Hand Controller Slew to an ObjectElectric Focuser Set Up ControllerSync to Target Set Anti-backlash Meridian TreatmentAlign Test Backlash Disp R.A Axis ErrorThree Star Alignment PEC Option Pole Star PositionPEC Playback Record PECSystem Self-Test Set Tracking RateSet User Objects Guide Options Set Slewing RatePark Scope Set Guider RateTo Zero Position Balance TestMaintenance and Servicing MaintenanceIOptron Customer Service Battery Replacement and Disposal InstructionsAppendix A. Technical Specifications GPSAppendix B. Go2NovaTM 8407 HC Menu Structure Page Appendix C. Firmware Upgrade Appendix D. Computer Control an iEQ45 Mount Appendix E. Go2NovaTM Star List Messier CatalogNamed Star List Modern Constellations Deep Sky Object List Double Star List SAO Atik Ioptron TWO Year TELESCOPE, MOUNT, and Controller Warranty