Celestron CGE925, CGE1100, CGE800, CGE1400 Appendix B RS-232 Connection, Communication Protocol

Page 64

Appendix B - RS-232 Connection

You can control your CGE telescope with a computer via the RS-232 port on the computerized hand control and using an optional RS-232 cable (#93920). Once connected, the CGE can be controlled using popular astronomy software programs.

Communication Protocol:

CGE-i communicates at 9600 bits/sec, No parity and a stop bit. All angles are communicated with 16 bit angle and communicated using ASCII hexadecimal.

Description

PC Command ASCII

Hand Control Response

Notes

Echo

Kx

X#

Useful to check communication

Goto Azm-Alt

B12AB, 4000

#

10 characters sent. B=Command,

 

 

 

12AB=Azm, comma, 4000=Alt. If

 

 

 

command conflicts with slew limits,

 

 

 

there will be no action.

Goto Ra-Dec

R34AB, 12CE

#

Scope must be aligned. If

 

 

 

command conflicts with slew limits,

 

 

 

there will be no action.

Get Azm-Alt

Z

12AB, 4000#

10 characters returned,

 

 

 

12AB=Azm, comma, 4000=Alt, #

Get RA-Dec

E

34AB, 12CE#

Scope must be aligned

Cancel Goto

M

#

 

Is Goto in Progress

L

0# or 1#

0=No, 1=Yes; "0" is ASCII

 

 

 

character zero

Is Alignment Complete

J

0# or 1#

0=No, 1=Yes

Commands below

 

 

 

available on version 1.6

 

 

 

or later

 

 

 

HC version

V

22

Two bytes representing V2.2

Stop/Start Tracking

Tx

#

Alt-Az tracking requires alignment

 

x = 0 (Tracking off)

 

 

 

x = 1 (Alt-Az on)

 

 

 

x = 2 (EQ-N)

 

 

 

x = 3 (EQ-S)

 

 

32-bit goto RA-Dec

r34AB0500,12CE0500

#

 

32-bit get RA-Dec

e

34AB0500,12CE0500#

The last two characters will always

 

 

 

be zero.

Commands below

 

 

 

available on version 2.2

 

 

 

or later

 

 

 

32-bit goto Azm-Alt

b34AB0500,12CE0500

#

 

32-bit get Azm-Alt

z

34AB0500,12CE0500#

The last two characters will always

 

 

 

be zero.

The cable required to interface to the telescope has an RS-232 male plug at one end and a 4-4 telephone jack at the other end. The wiring is as follows:

64

Image 64
Contents CGE800 CGE925 CGE1100 CGE1400 User Defined Objects Telescope Maintenance Some of the many standard features of the CGE include CGE 1400 Shown 12v Output JackSetting up the Tripod Power SupplyCounterweight DiagonalAttaching the Center Leg Brace Attaching the Electronics PierInstalling the Counterweight Bar Installing the CounterweightCounterweight Locking Screw Safety Screw Washer Attaching the Equatorial MountAttaching the Visual Back Attaching the Optical Tube to the MountDovetail Slide Bar Dovetail Locking Knobs Mounting Platform Installing the Star Diagonal Installing the EyepieceInstalling the Finderscope Adjusting the Mount Moving the Telescope ManuallyBalancing The Mount in R.A Balancing The Mount in DECAttaching the Motor Cables Powering the TelescopeTransporting the CGE Page CGE Hand Control Named Stars Named ObjectsDouble Stars Variable StarsAlignment Procedures Startup ProcedureAuto Two-Star Align Auto One-Star AlignLast Alignment Quick-AlignCGE Re-Alignment Object Catalog Selecting an ObjectSlewing to an Object Finding PlanetsTour Mode Constellation TourDirection Buttons Rate ButtonSetup Procedures Identify Scope Setup Features Precise GoToObserving Tip Helpful Hint Utility Features Helpful Hint Page CGE Ready Image Orientation Calculating Magnification FocusingDetermining Field of View General Observing Hints Celestial Coordinate System Motion of the Stars Latitude Scales Pointing at PolarisFinding the North Celestial Pole Declination Drift Method of Polar Alignment Observing the Moon Lunar Observing HintsObserving the Planets Planetary Observing HintsObserving the Sun Solar Observing HintsObserving Deep Sky Objects Seeing ConditionsSeeing Short Exposure Prime Focus Photography Eyepiece Projection FullLong Exposure Prime Focus Photography Planet ISO Moon Mercury Venus Mars Jupiter SaturnPeriodic Error Correction PEC Using Periodic Error Correction Terrestrial Photography MeteringReducing Vibration CCD ImagingFastar Compatible Optical System Fastar F/2 Imaging Medium size to small galaxies With Reducer/CorrectorPlanetary or Lunar Auto Guiding Care and Cleaning of the Optics CollimationCollimated telescope Should appear Symmetrical with Page At f/10 and 163 power with the CGE Page Technical Specifications Idle Current Appendix a Longitudes Latitudes Georgia Minnesota Rhode Island Canada Appendix B RS-232 Connection Communication ProtocolAdditional RS232 Commands Reset The Position Of Azm Or AltAppendix C Maps of Time Zones Page Page Page Page Page Page Page Celestron TWO Year Warranty