Pentair Time Master installation instructions Important Safety Precautions, Equipment Location

Page 1

LIMITED WARRANTY

Compool Corporationwarrantstot he purchaseroft his controlsystem,for the periodof one year from the date of originalpurchasefor use,that any defectiveproduct provedto be caused by faulty workmanship or faulty material, will be repaired or replaced at Compool'soption for no charge, providing the product is returned to Compool with all transportation charges prepaid.

First Ninety Days: During the first ninetydays after installation,if any Compoolcontrol shall be found to be defectivedue solely to faulty materialand workmanship,Compool Corporation will additionally cover the reasonable replacement cost charged by an authorized service company.

After Ninety Days: Between the ninety-first day and the end of the first year after installation, no allowanceswill be madefor labor for the removal or reinstallationof any soclaimed defective products

This warranty covers the Time Master Controller, LX-10Service Center, VOR-24 Valve Operators, and optionalRemote Controls, includingall componentsand parts. It does not include Valves or Sensors. It extends to the first retail purchaser and any subsequent owners of the system.

This limitedwarranty appliesonly to controlswhich have been installedand maintained in strict accordance with installationand operating instructionsprovided by Compool Corporation, using installation hardware supplied and/or recommended in writing by Compool, and to controls which have been connected to the correct supply voltage. This limited warranty does not apply to any controls which have been repaired or alteredby anyoneother than Compoolora personauthorizedby it; orwhich have been subject to misuse, neglect or accident; or which have been damaged by wind, freezing or other cause, thing, person or act of God; or which have been subject to damage in transit, during installation,or by someone other than Compool Corporation; or which havebeen damaged becauseof a defect in a component or part which is not part of the CompoolControlSystem; or uponwhich the serial number hasbeenaltered, effacedor removed.

This warranty gives you specific legal rights and you may also have other rightswhich vary from state to state. CompoolCorpora!ion does not authorizeany personto create any other obligation or liability in connection with Compool controls. Compool Corporation makes no warranty of merchantability or fitness for any use. Any implied warranty applicable to Compool controls is limited in duration to the duration of this written warranty.

Compool Corporation shall not be liable for consequential or incidental damages resultingfrom breachof this written warranty or any impliedwarranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation of incidental or consequential damages may not apply to you.

To exerclse this warranty, send defective unit, with copy of dated receipt, postage prepaid, to:

COMPOOL CORPORATION

599 Fairchild Drive, Mountain View, California 94043-2217

[mMEMBER

599 Fairchild Drive

Mountain View

California 94043-2217

Computerized Pool Systems N.,,oN.L(415) 964-2201

fie.. POOL I N S T I T U T t

INSTALLATION INSTRUCTIONS

TIME MASTER

POOL-SPA CONTROL SYSTEM

IMPORTANT SAFETY PRECAUTIONS:

All wiring must be performed by a qualified electrician.

Basic safety precautions and local codes should be observed when installing and using this electrical equipment.

FiEAD AND FOLLOW ALL INSTRUCTIONS

EQUIPMENT LOCATION:

All electrical equipment must be located five feet or more from pool or spa with the exception of the optional Spa-side Remote Control

1.LX-10Service Center at t!le equipment pad area

2.Time Master inside house or other weather-protectedarea

3.VOR-24 Valve Opemtors at threeport valves

4.W S 5 L Water Sensor at filter pump

5.SS100 Spaside Remote Control (optionar)at spa site

LOW VOLTAGE CABLES:

Determine lengths of 22AWG low voltage cable needed between equipment

1.6pair cable from Time Master to LX-10 Service Center.

2.2 conductor cable from gas heater to LX-10 Service Center.

3.Water Sensor is provided with 10 feet of 2 conductor cable.

4.Valve Operators are provided with 15 feet of 3 conductor cable

5.Spa-side Remote Control is provided with 100 feet of 4 conductor cable Remote Control is also available with 50. 150 or 200 feet of cable

Install cable. Place cable in plastic or metallic conduit where it runs underground ihrough concrete, etc

NOTE: Never install low voltage cable and high voltage wires i n the same conduit A minimum distance of 12" must be maintained between parallel runs of low voltage cable and AC current-carrying wires.

22AWG cable is available from Compool Corporation

PLUMBING:

Fol!ow recommended schematic (see next page) for location of threeport valves 2" dia. plumbing is advised to ensure optimum filter pump efficiency.

1.A Y2" spa makeupline, (incorporatinga Y2" manualgate or ball valve and, for elevated spas, aY2" checkvalve) should be providedaround the retum valve(seeschematic). This enables clean water to be circulated to the spa while the system is in POOL mode

2.Spa should be at or above the level of the pool If spa is attached to pool provide a dam between the two bodies of water to allow spa overflow into pool If spa is not attached to pool an overflow, sufficient in size to carry full pumpflow, must be installed at water level in the spa

Image 1
Contents Equipment Location Important Safety PrecautionsLOW Voltage Cables PlumbingSample Program Hydraulic and Electrical SchematicUnused Programs Operating Instructions Programming Setting the ClockSystem Options System START-UPHigh Voltage Wiring Additional Remote Control in Lieu of CleanerSPA Waterfall Control Electric Heater Control