LIMITED WARRANTY
Compool Corporationwarrantstot he purchaseroft his controlsystem,for the periodof one year from the date of originalpurchasefor use,that any defectiveproduct provedto be caused by faulty workmanship or faulty material, will be repaired or replaced at Compool'soption for no charge, providing the product is returned to Compool with all transportation charges prepaid.
First Ninety Days: During the first ninetydays after installation,if any Compoolcontrol shall be found to be defectivedue solely to faulty materialand workmanship,Compool Corporation will additionally cover the reasonable replacement cost charged by an authorized service company.
After Ninety Days: Between the
This warranty covers the Time Master Controller,
This limitedwarranty appliesonly to controlswhich have been installedand maintained in strict accordance with installationand operating instructionsprovided by Compool Corporation, using installation hardware supplied and/or recommended in writing by Compool, and to controls which have been connected to the correct supply voltage. This limited warranty does not apply to any controls which have been repaired or alteredby anyoneother than Compoolora personauthorizedby it; orwhich have been subject to misuse, neglect or accident; or which have been damaged by wind, freezing or other cause, thing, person or act of God; or which have been subject to damage in transit, during installation,or by someone other than Compool Corporation; or which havebeen damaged becauseof a defect in a component or part which is not part of the CompoolControlSystem; or uponwhich the serial number hasbeenaltered, effacedor removed.
This warranty gives you specific legal rights and you may also have other rightswhich vary from state to state. CompoolCorpora!ion does not authorizeany personto create any other obligation or liability in connection with Compool controls. Compool Corporation makes no warranty of merchantability or fitness for any use. Any implied warranty applicable to Compool controls is limited in duration to the duration of this written warranty.
Compool Corporation shall not be liable for consequential or incidental damages resultingfrom breachof this written warranty or any impliedwarranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation of incidental or consequential damages may not apply to you.
To exerclse this warranty, send defective unit, with copy of dated receipt, postage prepaid, to:
COMPOOL CORPORATION
599 Fairchild Drive, Mountain View, California
[mMEMBER
599 Fairchild Drive
Mountain View
California
Computerized Pool Systems N.,,oN.L(415)
fie.. POOL I N S T I T U T t
INSTALLATION INSTRUCTIONS
TIME MASTER
POOL-SPA CONTROL SYSTEM
IMPORTANT SAFETY PRECAUTIONS:
All wiring must be performed by a qualified electrician.
Basic safety precautions and local codes should be observed when installing and using this electrical equipment.
FiEAD AND FOLLOW ALL INSTRUCTIONS
EQUIPMENT LOCATION:
All electrical equipment must be located five feet or more from pool or spa with the exception of the optional
1.
2.Time Master inside house or other
3.
4.W S 5 L Water Sensor at filter pump
5.SS100 Spaside Remote Control (optionar)at spa site
LOW VOLTAGE CABLES:
Determine lengths of 22AWG low voltage cable needed between equipment
1.6pair cable from Time Master to
2.2 conductor cable from gas heater to
3.Water Sensor is provided with 10 feet of 2 conductor cable.
4.Valve Operators are provided with 15 feet of 3 conductor cable
5.
Install cable. Place cable in plastic or metallic conduit where it runs underground ihrough concrete, etc
NOTE: Never install low voltage cable and high voltage wires i n the same conduit A minimum distance of 12" must be maintained between parallel runs of low voltage cable and AC
22AWG cable is available from Compool Corporation
PLUMBING:
Fol!ow recommended schematic (see next page) for location of threeport valves 2" dia. plumbing is advised to ensure optimum filter pump efficiency.
1.A Y2" spa makeupline, (incorporatinga Y2" manualgate or ball valve and, for elevated spas, aY2" checkvalve) should be providedaround the retum valve(seeschematic). This enables clean water to be circulated to the spa while the system is in POOL mode
2.Spa should be at or above the level of the pool If spa is attached to pool provide a dam between the two bodies of water to allow spa overflow into pool If spa is not attached to pool an overflow, sufficient in size to carry full pumpflow, must be installed at water level in the spa