AUXILIARY EQUIPMENT CONTROL (OPTIONAL):

The standard Time Master system is provided with 3 power relays for controlling filter pump, pool cleaner, and auxiliary 1 (pool light).

It is possible to control additional equipment (such as a jet pump, air blower, spa light, etc) by installing extra relay kits (model RLY-LX). The LX-10 Service Center will accommodate a total of 7 relays Note: Further relays may be controlled by an addt tional Power Center (model LX-36).

lnstall RLY-LX Relay Kit at the LX-10 in accordance with instructions provided.

SPAaSIDE REMOTE CONTROL (OPTIONAL):

When the spa construction is completed, install optional Spa-side Remote Control (model SS100) in accordance with instructions provided:

1.Cut back the 11/2" dia pvc receptacle flush with spa wall finish or surface of deck

2.Making sure that screw threads are facing out, glue adapter into receptacle using pvc cement

3.Thread cable through gasket, and run through conduit to LX-10 low voltage compartment

4.Before installing SS-100, rotate 7 turns counterclockwise to avoid undue twisting of cable

5.Screw SS100 into adapter and finger-tighten. Caution: Do not use wrench

6.At the LX-10, cut off excess cable if necessary. Strip insulation '/a", and make connections to REMOTE SWITCHES screw terminals in accordance with wiring diagram located inside enclosure cover.

Connect black wire (switch common) to GND terminal, and connect red, yellow, and green wires to desired terminal for S P q AUX 1, AUX 2, AUX 3 and AUX 4. Note: for the convenience of the serviceman, the screw terminal can be unplugged from printed circuit board without disconnecting wires

INDOOR REMOTE CONTROL (OPTIONAL):

Select a convenient location inside the house or other weather-protected area to mount the LVS-3(3 button indoor remote) or LVSSTR(3 button indoor remote w/ digital temperature display).

Install in accordance with instructions provided At the LX-10 low voltage c o n partment, strip jacket of cable 6" to identify the twisted pairs and assure correct connections Strip insulation of each wire '/4", and connect to appropriate screw terminals at REMOTE SWITCHES and REMOTE LAMPS terminal:

1.Select any three circuits from SPA, AUX 1, AUX 2, AUX 3, and AUX 4.

2.Number the circuits 1, 2, and 3.

3.Make sure that the corresponding SW and LMP wires from the Indoor Remote are connected to the appropriate circuit at the LX-10 REMOTE SWITCHES and REMOTE LAMPS terminal.

NOTE: If the LVS3TR is being used install the second Water Sensor (included) in accordance with previous instructions and run cable to LX-10 low voltage c o n partment Wire nut to yellowblack pair of wires from LVS-3TR cable (red connects to yellow, green connects to black), in accordance with wiring diagram located inside LVS-3TR

ALabel Set for indoor remote controls (model LBL-100) is available from Compool Corporation. This set of 100 different labels provides custom e q u i p ment identification at each remote control button.

SYSTEM START-UP

Apply power to the system.

At theTime Master, pullout batteryshield toactivate back-upbattery, and push HOURS button until digital readout is displayed

At the LX-10 Service center, turn SYSTEM CONTROL Switch to"SERV1CE position and FLOW CONTROL Switch to "POOL" position.

Check that Valve Operators have rotated to correct positions Toadjust position of any valve, simply reverse the cable plug on the side of Valve Operator.

At the LX-10 Service Center, turn MANUAL CONTROL Switches to " O N positions and check that all equipment is operating.

Turn OUTDOOR REMOTES Switch to"ONn position and check that optional Spa-side Remote Control is functioning correctly.

Turn MANUAL CONTROL Switches to"OFF1 positions The system is now ready to be operated as desired

SYSTEM OPTIONS

TWO SPEED PUMP CONTROL:

If the system is equipped with a two speed filter pump, a Dual Speed Relay Kit (model RLY-LXD) should be added at the LX-10 in accordance with installation instructions provided

The system will automatically run the filter pump in high speed under any of the following conditions

1.Whenever the heater is o n

2.Whenever pool cleaner is running

3.Whenever spa is running

It is possible to eliminate one or more of these conditions by adjusting U11 Program Switch, which is located at the top of the printed circuit board See RLY-LXD installation instructions for details

PROGRAMMABLE TWO SPEED PUMP CONTROL:

If the system is equipped with a two speed filter pump, it is additionally possible to program the pump to run in high speed by using AUX 1 Program Button on the Time Master Controller. However, this feature will only operate when the filter pump is running Install RLY-LXD as above.

Adjust U10 Program Switch (located at the bottom of the printed circuit board) so that Switches #1, #3 and # 6 are programmed ON, and Switches #2, #4, #5, and #7 are programmed OFF.

ADDITIONAL VALVE CONTROL:

It is possible to add valve operators(mode1VOR-24) to the system to actuate additional threeport valvesfor pool cleaning or for a custom hydraulic feature(such as a fountain, waterfall second spa, etc). A total of three valve operators may be added. InstallValve Module (model MODVLV1) at LX-10 low voltage compartment in accordance with instructions provided, and connect valve operators accordingly.

Image 5
Contents Equipment Location Important Safety PrecautionsLOW Voltage Cables PlumbingUnused Programs Hydraulic and Electrical SchematicSample Program Operating Instructions Programming Setting the ClockSystem Options System START-UPHigh Voltage Wiring Additional Remote Control in Lieu of CleanerSPA Waterfall Control Electric Heater Control