LOW VOLTAGE WlHlNti UlAGHAM
Do not untwist pairs.
It is neccessary to retain wires in pairs so that appropriate connections can be identified.
OPERATING INSTRUCTIONS
GENERAL CONTROL FEATURES
FILTER PUMP OFF DELAY. This causes the filter pump to run an additional 4 minutes every time it is turned off. The purpose of this is to protect the gas heater and plumbing from possible scale
POOLCLEANER ON DELAY. Every time the pool cleaner pump is turned on, this circuit prevents it from running until 4 minutes have passed. This protects the pump from damage caused by air in the water lines that may have entered into the plumbing since it was last used.
| TIME CONTROL |
EQUIPMENT B U l T O N FUNCTIONS: | |
FILTER: | Turns filter pump ON and circulates POOL water. |
CLN R: | Turns filter and cleaner pumps ON. (Cleaner delayed 4 minutes) |
SPA: | Turns filter pump ON and circulates SPAwater. Allows heater to |
| operate. Overrides CLNR key and turns pool cleaner pump OFF, |
| even if CLNR "flag" is present. |
AUX1: | Turns electrically controlled function ON. (lights, jets, etc.) |
I I I
0 0 0
n k k k
Z Z Z Z o m m m
t t t t
X O J Z
J W W (+1 :
m (1:0
I I I
0 0 0
n k k k
Z Z Z Z o m m m
t t t t
X 3 X Z
d J J ( 1 :
m m m o
-
(1:
:IN I Ell
LA
- ~ m
a a a
r 5 5 p
< < < N | HIGH VOLTAGE RELAYS |
J J J + |
t t t t
x k x n
m 3 m r r
R 6
R 7
TEMPERATURE CONTROL
WATER TEMPERATURE Display:
Pool temperature is displayed when the pool is operating, spa temperature when the spa is operating. If filter pump is off, display may be meaningless
THERMOSTAT:
Desired pool or spa temperature is set here.
| HEATER CONTROL |
SWITCH POSITIONS: | |
PO0L: | Allows heating of pool to the preset temperature level. |
SPA: | Allows heating of spa to the preset temperature level. |
OFF: | Allows no heating. |
HEATER ON Light:
When lit, indicates that heater is on.
STATUS DISPLAY
The presence of a light next to an equipment label indicates that it is ON. The absence of a light indicates OFF.
DELAY CANCEL B U l T O N FUNCTIONS:
FILTER: | To override the Filter Delay Circuit, press CANCEL OFF DELAY |
| button. Provided that there is no "flag" present at either |
| FILTER, CLNR or SPA buttons, the filter pump will shut off |
| immediately. |
CLNR: | To override the Cleaner Delay Circuit, press CANCEL ON |
| DELAY button. Provided that there is a "flag" present at the |
| CLNR button, the pool cleaner pump will start immediately. |
| If SPA is on, CLNR is inoperative. |