Intel 6300ESB manual 4.0Reference Thermal Solution, 4.1Reliability Requirements

Page 11
Reference Thermal Solution

Reference Thermal Solution

4.0Reference Thermal Solution

Based on a component local operating environment of natural convection (zero LFM of airflow) with a maximum local-ambient temperature of 55° C, the Intel 6300ESB ICH component does not require an attached heatsink to meet thermal specifications. For systems where the local-ambient temperature is severe (greater than 55° C, natural convection), a component level thermal solution or system thermal solution improvement may be required. Attaching a heatsink to the package case and/or improving airflow at the component may be potential solutions.

4.1Reliability Requirements

If an attached heatsink is implemented due to a severe component local operating environment, the reliability requirements in Table 4 are recommended. Each motherboard, heatsink, and attach combination may vary the mechanical loading of the component. It is recommended that the user carefully evaluate the reliability of the completed assembly prior to use in high volume.

Table 4. Reliability Requirements

Test1

Requirement

Pass/Fail Criteria2

 

 

 

Mechanical Shock

50g, board level, 11 msec, 3 shocks/axis

Visual check and electrical functional test

 

 

 

Random Vibration

7.3g, board level, 45 min/axis, 50 Hz to

Visual check and electrical functional test

2000 Hz

 

 

 

 

 

Temperature Life

85° C, 2000 hours total, checkpoints at

Visual check

168, 500, 1000, and 2000 hours

 

 

 

 

 

Thermal Cycling

-5° C to +70° C, 500 cycles, ° C/min rise

Visual check

and fall

 

 

 

 

 

Humidity

85% relative humidity, 55° C, 1000 hours

Visual check

 

 

 

NOTES:

1.The above tests should be performed on a sample size of at least 12 assemblies from 3 lots of material.

2.Additional pass/fail criteria may be added at the discretion of the user.

Intel® 6300ESB I/O Controller Hub Thermal and Mechanical Design Guide

11

Image 11
Contents February Intel 6300ESB I/O Controller HubThermal and Mechanical Design Guide Contents Revision History ContentsFigures TablesThis page intentionally left blank Table 1. Definition of Terms 1.0Introduction1.1Definition of Terms IntroductionDocument Reference DocumentsReference Documents Packaging Technology 2.0Packaging TechnologyPackaging Technology 3.2Case Temperature Metrology 3.0Thermal Specifications3.1Case Temperature and Thermal Design Power Thermal SpecificationsThis page intentionally left blank Table 4. Reliability Requirements 4.0Reference Thermal SolutionReference Thermal Solution 4.1Reliability RequirementsThis page intentionally left blank Mechanical Drawings Appendix A Mechanical DrawingsMechanical Drawings