Department | Current Data | Projected Data | Devices |
|
| (In 5 Years) |
|
|
|
|
|
*One HP StorageWorks DAT24 autoloader is currently used to locally back up the 12 GB of data. The other HP StorageWorks DAT24 autoloader is used to back up the IDB and configuration files. The rest of the data in this department is backed up remotely to the HP StorageWorks DLT 4115 library.
The remaining 4 HP StorageWorks DAT24 autoloaders are used in a separate R&D system, which is not of our configuration.
The software components proposed for the Enterprise Backup solution include HP Data Protector A.06.10.
Proposed solution in detail
The following is a detailed account of the proposed solution:
•Cell Configuration
All clients and servers should be configured in a single Data Protector cell. The Data Protector Cell Manager can run on the Windows 2000 Server of the English Department.
All systems in the cell should be on the same LAN for maximum performance. The Cell Manager should also be the Installation Server for Windows. Use the
The proposed backup environment is as depicted in Figure 92 on page 305:
304 | Backup scenarios |