3.1. AC Input

Table 1 lists AC input voltage and frequency requirements for continuous operation. The power supply shall be capable of supplying full-rated output power over two input voltage ranges rated 100-127 VAC and 200-240 VAC RMS nominal. The correct input range for use in a given environment may be either switch-selectable or auto-ranging. The power supply shall automatically recover from AC power loss. The power supply must be able to start up under peak loading at 90 VAC.

Table 1. AC Input Line Requirements

Parameter

Minimum

Nominal+

Maximum

 

 

 

 

Vin (115 VAC)

90

115

135

Vin (230 VAC)

180

230

265

Vin Frequency

47

--

63

 

 

 

 

+Note: Nominal voltages for test purposes are considered to be within ±1.0 V of nominal.

Unit

VAC rms

VAC rms

Hz

3.1.1. Input Over-current Protection

The power supply shall incorporate primary fusing for input over-current protection to prevent damage to the power supply and meet product safety requirements. Fuses should be slow-blow–type or equivalent to prevent nuisance trips.

3.1.2. Inrush Current Limiting

Maximum inrush current from power-on (with power on at any point on the AC sine) and including, but not limited to, three line cycles, shall be limited to a level below the surge rating of the input line cord, AC switch if present, bridge rectifier, fuse, and EMI filter components. Repetitive ON/OFF cycling of the AC input voltage should not damage the power supply or cause the input fuse to blow.

. For Denmark and Switzerland international safety requirements, if the internal over-current protective devices exceed 8A for Denmark and 10A for Switzerland, then the power supply must pass international safety testing to EN 60950 using a maximum 16A over-current protected branch circuit, and this 16A (time delay fuse) branch circuit protector must not open during power supply abnormal operation (output short circuit and component fault) testing.

9

Image 9
Contents Version ATX12VImportant Information and Disclaimers Contents Mechanical SafetyEnvironmental Electromagnetic CompatibilityTables FiguresScope IntroductionIncreased +12 VDC output capability Minimum EfficiencyMain Power Connector Separate current limit for 12V2 on the 2x2 connectorTerminology Applicable Documents Document TitleDescription AC Input ElectricalInput Over-current Protection Inrush Current LimitingInput Under-voltage RegulatoryOther Certifications and/or Declarations Catastrophic Failure Protection DC OutputDC Voltage Regulation DC Output Voltage RegulationRemote Sensing Typical Power Distribution12V power watts PowerMin Max Current Output AmpsCross Loading Graph for 300W Configuration Typical Power Distribution for a 300 W ATX12V ConfigurationCross Loading Graph for 350W Configuration Typical Power Distribution for a 350 W ATX12V ConfigurationMin Max Peak Current Output Amps Typical Power Distribution for a 400 W ATX12V ConfigurationEfficiency Power Limit / Hazardous Energy LevelsGeneral Minimum Efficiency Vs LoadLoading Table for Efficiency Measurements Other Low Power System Requirements Energy Star Input Power ConsumptionOutput Ripple/Noise Energy StarMax. Ripple & Noise MVpp DC Output Noise/RippleCapacitive Load Output Transient ResponseDC Output Transient Step Sizes Output Capacitive LoadsTiming / Housekeeping / Control 10. +5 VDC / +3.3 VDC Power SequencingClosed-loop Stability Voltage Hold-up TimePwrok Signal Characteristics PwrokPSON# 3. +5 VSB PSON# Signal CharacteristicsReset after Shutdown Power-on Time8. +5 VSB at AC Power-down RisetimeOver-voltage Protection Output ProtectionShort-circuit Protection No-load OperationOutput Bypass Over-temperature ProtectionPhysical Dimensions MechanicalLabeling / Marking Second optional fan may go in this location Second optional Airflow / Fan DC Connectors AC Connector+33V 12V +5V+12V1 +5V Pin Signal Color ATX Main Power ConnectorPeripheral Connectors 2. +12 V Power ConnectorConnector Molex 39-01-2040 or equivalent Pin Signal AWG WireFloppy Drive Connector Serial ATA Power ConnectorWire Signal Connector AMP 171822-4 or equivalent Pin Signal AWG WireEnvironmental TemperatureThermal Shock Shipping HumidityMechanical Shock Random VibrationAcoustics Electromagnetic Compatibility EmissionsImmunity Input Line Current Harmonic Content and Line Flicker Magnetic Leakage FieldsHarmonic Limits, Class D Equipment Component De-rating ReliabilityNorth America SafetyProscribed Materials International