ATX12V Power Supply Design Guide

Version 2.0

3.3.4. Power-on Time

The power-on time is defined as the time from when PS_ON# is pulled low to when the +12 VDC, +5 VDC, and +3.3 VDC outputs are within the regulation ranges specified in Section 3.2.1. The power-on time shall be less than 500 ms (T1 < 500 ms).

+5 VSB shall have a power-on time of two seconds maximum after application of valid AC voltages.

3.3.5. Risetime

The output voltages shall rise from 10% of nominal to within the regulation ranges specified in Section 3.2.1 within 0.1 ms to 20 ms (0.1 ms T2 20 ms).

There must be a smooth and continuous ramp of each DC output voltage from 10% to 90% of its final set-point within the regulation band, while loaded as specified in Section 3.2.3. The smooth turn-on requires that, during the 10% to 90% portion of the rise time, the slope of the turn-on waveform must be positive and have a value of between 0 V/ms and [Vout,nominal / 0.1] V/ms. Also, for any 5 ms segment of the 10% to 90% risetime waveform, a straight line drawn between the end points of the waveform segment must have a slope [Vout,nominal / 20] V/ms.

3.3.6. Overshoot at Turn-on / Turn-off

The output voltage overshoot upon the application or removal of the input voltage, or the assertion/deassertion of PS_ON#, under the conditions specified in Section 3.1, shall be less than 10% above the nominal voltage. No voltage of opposite polarity shall be present on any output during turn-on or turn-off.

3.3.7. Reset after Shutdown

If the power supply latches into a shutdown state because of a fault condition on its outputs, the power supply shall return to normal operation only after the fault has been removed and the PS_ON# (or AC input) has been cycled OFF/ON with a minimum OFF time of

1 second.

3.3.8. +5 VSB at AC Power-down

After AC power is removed, the +5 VSB standby voltage output should remain at its steady state value for the minimum hold-up time specified in Section 3.2.11 until the output begins to decrease in voltage. The decrease shall be monotonic in nature, dropping to

0.0V. There shall be no other perturbations of this voltage at or following removal of AC power.

25

Image 25
Contents Version ATX12VImportant Information and Disclaimers Contents Mechanical SafetyEnvironmental Electromagnetic CompatibilityTables FiguresScope IntroductionIncreased +12 VDC output capability Minimum EfficiencySeparate current limit for 12V2 on the 2x2 connector Main Power ConnectorTerminology Document Title Applicable DocumentsDescription AC Input ElectricalInput Over-current Protection Inrush Current LimitingRegulatory Input Under-voltageOther Certifications and/or Declarations Catastrophic Failure Protection DC OutputDC Voltage Regulation DC Output Voltage RegulationRemote Sensing Typical Power Distribution12V power watts PowerMin Max Current Output AmpsCross Loading Graph for 300W Configuration Typical Power Distribution for a 300 W ATX12V ConfigurationCross Loading Graph for 350W Configuration Typical Power Distribution for a 350 W ATX12V ConfigurationMin Max Peak Current Output Amps Typical Power Distribution for a 400 W ATX12V ConfigurationEfficiency Power Limit / Hazardous Energy LevelsGeneral Minimum Efficiency Vs LoadLoading Table for Efficiency Measurements Other Low Power System Requirements Energy Star Input Power ConsumptionOutput Ripple/Noise Energy StarMax. Ripple & Noise MVpp DC Output Noise/RippleCapacitive Load Output Transient ResponseDC Output Transient Step Sizes Output Capacitive LoadsTiming / Housekeeping / Control 10. +5 VDC / +3.3 VDC Power SequencingClosed-loop Stability Voltage Hold-up TimePwrok Pwrok Signal CharacteristicsPSON# 3. +5 VSB PSON# Signal CharacteristicsReset after Shutdown Power-on Time8. +5 VSB at AC Power-down RisetimeOver-voltage Protection Output ProtectionShort-circuit Protection No-load OperationOutput Bypass Over-temperature ProtectionMechanical Physical DimensionsLabeling / Marking Second optional fan may go in this location Second optional Airflow / Fan DC Connectors AC Connector+5V +33V 12V+12V1 +5V Pin Signal Color ATX Main Power ConnectorPeripheral Connectors 2. +12 V Power ConnectorConnector Molex 39-01-2040 or equivalent Pin Signal AWG WireFloppy Drive Connector Serial ATA Power ConnectorWire Signal Connector AMP 171822-4 or equivalent Pin Signal AWG WireEnvironmental TemperatureThermal Shock Shipping HumidityRandom Vibration Mechanical ShockAcoustics Emissions Electromagnetic CompatibilityImmunity Magnetic Leakage Fields Input Line Current Harmonic Content and Line FlickerHarmonic Limits, Class D Equipment Component De-rating ReliabilityNorth America SafetyProscribed Materials International