Intel ATX12V manual Second optional

Page 30

ATX12V Power Supply Design Guide

Version 2.0

.

Second optional

Optional Venting Area

53 REF

fan may be located

 

 

in optional venting

 

 

area or on topside.

 

 

WIRE HARNESS

11.0 x 5.0 cutouts (4X);

min 6.0 clearance under16 REF cutout from inside top cover.

 

 

150 REF

20.0

 

 

4.0X6

 

 

(2X) See Note 5.

 

 

94.0

 

 

5.0

 

 

 

 

Area on top surface

 

 

146.0

inside dotted lines should

 

Preferred location of

have 60% minimum open

 

 

area for proper venting.

 

manufacturer label

140 REF

80.0

Eight rectangular holes

 

 

 

 

 

are for air duct mounting

 

 

 

to direct airflow across

 

 

5.0

processor heatsink.

 

 

 

 

45.0

 

8.0

114.0

 

No. 6-32 UNC-2B THREADED HOLE (4X)

138.0

86 REF

Notes; unless otherwise specified:

See Note 4.

9.0 x 3.2 cutouts (4X);

1. Dimensions are in mm.

 

min 5.0 clearance under

2. Drawing is not to scale.

 

 

cutout from inside top cover.

3. Tolerances:

 

 

 

X +/- 1

 

 

 

X.X +/- 0.5

 

 

 

4. If a wire grill is required

64.0

 

 

for acoustics or thermals,

 

74.0

the grill and screws must

 

 

 

be flush mounted.

 

 

 

5. Bottom side (not pictured)

 

 

 

may be user-accessible in

 

 

 

final system installation.

 

114.0

6.0

Cover openings as

16.0

 

necessary to prevent

6.0 (2X)

 

 

access to non-SELV

 

 

 

 

 

circuitry and to meet product

 

 

 

safety requirements.

 

 

psu_duct_mount

Figure 9. Power Supply Dimensions for Chassis That Require Top Venting

30

Image 30
Contents ATX12V VersionImportant Information and Disclaimers Contents Environmental SafetyMechanical Electromagnetic CompatibilityFigures TablesIncreased +12 VDC output capability IntroductionScope Minimum EfficiencyMain Power Connector Separate current limit for 12V2 on the 2x2 connectorTerminology Applicable Documents Document TitleDescription Input Over-current Protection ElectricalAC Input Inrush Current LimitingInput Under-voltage RegulatoryOther Certifications and/or Declarations DC Voltage Regulation DC OutputCatastrophic Failure Protection DC Output Voltage RegulationTypical Power Distribution Remote SensingMin Max Power12V power watts Current Output AmpsTypical Power Distribution for a 300 W ATX12V Configuration Cross Loading Graph for 300W ConfigurationTypical Power Distribution for a 350 W ATX12V Configuration Cross Loading Graph for 350W ConfigurationTypical Power Distribution for a 400 W ATX12V Configuration Min Max Peak Current Output AmpsGeneral Power Limit / Hazardous Energy LevelsEfficiency Minimum Efficiency Vs LoadLoading Table for Efficiency Measurements Output Ripple/Noise Energy Star Input Power ConsumptionOther Low Power System Requirements Energy StarDC Output Noise/Ripple Max. Ripple & Noise MVppDC Output Transient Step Sizes Output Transient ResponseCapacitive Load Output Capacitive LoadsClosed-loop Stability 10. +5 VDC / +3.3 VDC Power SequencingTiming / Housekeeping / Control Voltage Hold-up TimePwrok Signal Characteristics PwrokPSON# PSON# Signal Characteristics 3. +5 VSB8. +5 VSB at AC Power-down Power-on TimeReset after Shutdown RisetimeShort-circuit Protection Output ProtectionOver-voltage Protection No-load OperationOver-temperature Protection Output BypassPhysical Dimensions MechanicalLabeling / Marking Second optional fan may go in this location Second optional Airflow / Fan AC Connector DC Connectors+33V 12V +5V+12V1 +5V ATX Main Power Connector Pin Signal ColorConnector Molex 39-01-2040 or equivalent 2. +12 V Power ConnectorPeripheral Connectors Pin Signal AWG WireWire Signal Serial ATA Power ConnectorFloppy Drive Connector Connector AMP 171822-4 or equivalent Pin Signal AWG WireThermal Shock Shipping TemperatureEnvironmental HumidityMechanical Shock Random VibrationAcoustics Electromagnetic Compatibility EmissionsImmunity Input Line Current Harmonic Content and Line Flicker Magnetic Leakage FieldsHarmonic Limits, Class D Equipment Reliability Component De-ratingSafety North AmericaInternational Proscribed Materials