Eiki EIP-WX5000 Wired Remote Control Terminal Specifications, Function and transmission codes

Page 13

Wired Remote Control Terminal Specifications

Specifications of wired remote control input

ø3.5 mm minijack

External: GND

Internal: +3.3V

Function and transmission codes

 

SYSTEM CODE

 

 

DATA CODE

 

 

JUDGEMENT

CONTROL

 

 

 

 

CODE

 

 

 

 

 

 

 

 

 

 

 

 

 

ITEM

C1

C2

C3

C4

C5

C6

C7

C8

C9

C10

C11 C12 C13

C14 C15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STANDBY-ON

1

0

1

1

0

0

1

1

0

1

0

0

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZOOM +

1

0

1

1

0

0

0

0

1

0

1

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZOOM -

1

0

1

1

0

1

0

0

1

0

1

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOCUS +

1

0

1

1

0

0

0

1

0

0

1

1

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOCUS -

1

0

1

1

0

1

0

1

0

0

1

1

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H&V LENS SHIFT

1

0

1

1

0

0

0

1

1

0

0

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KEYSTONE

1

0

1

1

0

1

1

0

1

0

0

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MENU

1

0

1

1

0

0

0

1

0

0

0

1

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

'

1

0

1

1

0

0

0

1

1

1

0

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

\

1

0

1

1

0

0

0

0

0

1

0

1

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

0

1

1

0

1

1

1

1

0

0

1

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"

1

0

1

1

0

1

0

1

1

1

0

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTER

1

0

1

1

0

1

1

1

0

1

0

1

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNDO

1

0

1

1

0

1

0

0

1

1

0

1

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAGNIFY +

1

0

1

1

0

1

0

1

1

0

1

1

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAGNIFY -

1

0

1

1

0

1

0

1

1

0

1

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM CODE

 

 

DATA CODE

 

 

JUDGEMENT

CONTROL

 

 

 

 

CODE

 

 

 

 

 

 

 

 

 

 

 

 

 

ITEM

C1

C2

C3

C4

C5

C6

C7

C8

C9

C10

C11 C12 C13

C14 C15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FREEZE

1

0

1

1

0

1

0

1

1

0

0

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOL +

1

0

1

1

0

0

0

1

0

1

0

0

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOL -

1

0

1

1

0

1

0

1

0

1

0

0

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BREAK TIMER

1

0

1

1

0

0

0

1

0

1

1

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHUTTER OPEN

1

0

1

1

0

0

1

0

0

1

0

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHUTTER CLOSE

1

0

1

1

0

1

1

0

0

1

0

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MUTE

1

0

1

1

0

1

1

1

0

1

0

0

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTO SYNC

1

0

1

1

0

0

1

0

1

1

1

1

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PICTURE MODE

1

0

1

1

0

1

0

0

1

1

1

0

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RESIZE

1

0

1

1

0

0

1

1

1

1

0

1

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPUTER1

1

0

1

1

0

1

0

1

0

1

1

0

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPUTER2

1

0

1

1

0

0

1

1

0

1

1

0

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DVI-D

1

0

1

1

0

1

0

1

0

1

1

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HDMI

1

0

1

1

0

1

0

0

0

1

0

0

1

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIDEO

1

0

1

1

0

0

1

0

0

1

1

0

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-VIDEO

1

0

1

1

0

1

1

0

0

1

1

0

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wired remote control function code

 

 

 

 

 

LSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C1

 

 

System Code

 

 

C5

C6

 

 

 

Data Code

 

 

 

C13

C14

C15

 

 

 

 

 

 

 

 

 

 

1

 

0

1

1

 

0

*

*

 

*

*

*

*

 

*

*

1

0

System codes C1 to C5 are fixed at “10110”.

Codes C14 and C15 are reverse confirmation bits, with “10” indicating “Front” and “01” indicating “Rear”.

EIKI remote control signal format

Transmission format: 15-bit format

D

67.5 ms

D

D

D

D

D

67.5 ms

D

D

D

D

D

D

D

Wave form of output signal: Output using pulse position modulation

t

T1

“1”

T0

“0” “0” “0”

D

26.4 s

“0” “1” “0”

t

t = 264 µs

Pulse carrier frequency = 455/12 kHz

T0

= 1.05 ms

Duty ratio = 1:1

T1

= 2.10 ms

 

Transmission control code

15 bit

C1

C2

C3

C4

C5

C6

C7

C8

C9

C10

C11

C12

C13

C14

C15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data

Mask

Data

 

System Address

 

 

Function Key Data Bit

 

 

 

Deter-

 

 

 

 

 

 

Expansion

 

 

 

 

 

 

 

mination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example of Reverse D to D

D

C1

C2

C3

C4

C5

C6

C7

C8

C9

C10

C11

C12

C13

C14

C15

 

1

0

1

1

0

1

0

0

0

0

0

0

0

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

C1

C2

C3

C4

C5

C6

C7

C8

C9

C10

C11

C12

C13

C14

C15

 

1

0

1

1

0

0

1

1

1

1

1

1

1

0

1

D to D Common Data Bit

Reverse in D

13

Image 13
Contents Setup Manual Standard Setup Front Projection Setting up the ScreenThrow Distance Screen Size and Projection DistanceF2.5, f=25.5-32 mm Signal Input Normal ModeF2.5, f=11.6 mm Fixed Wide Lens AH-55201F2.5, f=17.1 mm Fixed Wide Lens AH-55301F2.5, f=21.2-25.8 mm Wide-zoom Lens AH-55401F2.5, f=31.9-42.5 mm Tele-zoom Lens AH-55601F2.5, f=40.8-62.8 mm Tele-zoom Lens AH-55701F2.5, f=62.1-97.8 mm Tele-zoom Lens AH-55801Pin female connector Connecting Pin AssignmentsConnecting Pin Assignments Specifications of wired remote control input Wired Remote Control Terminal SpecificationsEiki remote control signal format Function and transmission codesComputer control Communication conditions RS-232C Specifications and CommandsBasic format W R CommandsReturn PC RGB FAO CLR Temp Parameter 4500K 5500K 6500K Network settings on the computer Setting up the Projector Network EnvironmentConnecting the Pro- jector to a Computer Click Properties Setting an IP Address for the ComputerSetting up the Projector Network Environment Setting up a Network Connection for the Projector DNS Controlling the Projector via LAN Controlling the Projector Using Internet ExplorerControlling the Projector Confirming the ProjectorSetting the Security Setting and AdjustingSetting for Sending E-mail when an Error Occurs Making General Settings for the Network NetworkMail Recipient Settings When Connecting Using RS-232C Setting the Projector Using RS-232C or TelnetInput setup and press the Enter key InputPJS11234and press theEn- ter keyClickstartfrom theWindows desk- top and select Run When Connecting Using TelnetAdvanced Setup Menu Setup Menu Main MenuVView All Setting View Setting Detail ListSet Items Quit without Saving Set Save Settings and QuitSSave & Quit Tings QQuit UnchangedDefault Gateway Setting IP Address SettingSubnet Mask Setting User Name SettingProjector Name Setting Password SettingDhcp Client Setting RS-232C Baud Rate SetSetting Auto Logout Time Disconnecting All ConnecEntering Advanced Setup Menu Data Port SettingCarrying out Network Ping Test Setting of Accept IP Ad- dressAccepting All IP Addresses Return to Default Settings Setting of Search PortReturn to Main Menu Stack Projection Projector 1 Master Setting up the Stack ProjectionProjector 2 Slave Turn off the both projectorsProjector Slave Projector MasterVideo Wall Projection Projector Setting up the Video Wall Projection BasicClick Video Wall on the menu Access one of the four projectors via Internet ExplorerReturning to the Default Video Wall Setup Adjusting the Position Horizontally and VerticallyAssigning the Projected Image on the Video Wall Setup Select 1 X 1 on Division Click the assigning buttonVideo Wall Projection Setting up the Video Wall Projection Application Jectors as shown below Change the TCP/IP settings for the computer as shown belowClick Stack on the menu Select Slave on Stack Setting Click Stack on the menu Select Master on Stack SettingMake the IP address for each pro- jector as shown below Repeat the same procedure from the to 12 for the projector 3 Resetting the Lamp Timer of the Projector via LAN Close HyperTerminal Resetting the Lamp Timer of the Projector via LANWhen connecting the projector using serial-connection TroubleshootingTroubleshooting \ After the initialization, carry out setting again Units inches mm DimensionsWhen AH-55301 is installed When AH-55201 is installedWhen AH-55401 is installed When AH-55501 is installed

EIP-WX5000, EIP-WX5000L specifications

The Eiki EIP-WX5000 and EIP-WX5000L are cutting-edge projectors designed for high-performance presentations and immersive viewing experiences. Both models are equipped with advanced technologies that cater to the needs of professional environments, such as conference rooms, lecture halls, and large venues.

One of the standout features of the EIP-WX5000 series is its high brightness capability, with a luminosity of up to 5000 lumens. This ensures that images remain vibrant and visible even in well-lit environments, making it ideal for business presentations or educational settings where lighting conditions can vary. The WXGA resolution (1280 x 800 pixels) offers a sharp and clear image quality, enhancing the details and clarity of presentations and videos alike.

Both projectors leverage DLP technology, known for its durability and exceptional color accuracy. This technology enables a richer color palette and minimizes the risk of color decay over time, ensuring that users can rely on consistent performance. The EIP-WX5000 and EIP-WX5000L also feature a contrast ratio of up to 3000:1, providing deeper blacks and brighter whites, which accentuates the depth of the projected image.

Flexibility in installation is another appealing characteristic of these projectors. They come with a variety of lens options that support short throw, long throw, and ultra-short throw configurations. This adaptability makes them suitable for different room layouts and sizes, allowing users to set up the projector in a way that best suits their space.

Connectivity is a key component in today’s technology, and the EIP-WX5000 series does not disappoint. The projectors are equipped with multiple input options including HDMI, VGA, and USB, facilitating easy connections with a wide range of devices such as laptops, tablets, and Blu-ray players. The inclusion of built-in networking capabilities also allows for remote management and control via a web browser, enhancing convenience for IT departments.

For those concerned about noise levels, both models operate quietly, making them suitable for environments where distractions must be minimized. Additionally, they offer extensive lamp life, which contributes to lower maintenance costs over time.

In conclusion, the Eiki EIP-WX5000 and EIP-WX5000L projectors are engineered for excellence in presentation quality, adaptability, and ease of use, making them highly favorable for professional applications across various industries.