Eiki EIP-WX5000L specifications CLR Temp Parameter 4500K 5500K 6500K

Page 19

 

 

 

 

 

 

 

 

 

RS-232C Specifications and Commands

 

 

 

 

 

 

 

 

 

 

 

 

RETURN

 

CONTROL CONTENTS

COMMAND

PARAMETER

 

Power ON

Standby mode

 

 

 

 

 

 

 

 

 

 

 

(or 40-second startup time)

 

 

 

 

 

 

 

 

 

 

 

 

Digital Shift

-40 – +40

 

L

N

D

S

_

*

* *

OK or ERR

 

ERR

OSD Display

Normal

 

I

M

D

I

_

_

_ 1

OK or ERR

 

ERR

 

Level A

 

I

M

D

I

_

_

_ 2

OK or ERR

 

ERR

 

Level B

 

I

M

D

I

_

_

_ 0

OK or ERR

 

ERR

Video System

Auto

 

M

E

S

Y

_

_

_ 1

OK or ERR

 

ERR

Selection

PAL

 

M

E

S

Y

_

_

_ 2

OK or ERR

 

ERR

 

SECAM

 

M

E

S

Y

_ _ _ 3

OK or ERR

 

ERR

 

NTSC 4.43

 

M

E

S

Y

_ _ _ 4

OK or ERR

 

ERR

 

NTSC 3.58

 

M

E

S

Y

_ _ _ 5

OK or ERR

 

ERR

 

PAL – M

 

M

E

S

Y

_ _ _ 6

OK or ERR

 

ERR

 

PAL – N

 

M

E

S

Y

_ _ _ 7

OK or ERR

 

ERR

Background

Logo

 

I

M

B

G

_

_

_ 1

OK or ERR

 

ERR

Selection

Custom

 

I

M

B

G

_

_

_ 2

OK or ERR

 

ERR

 

Blue

 

I

M

B

G

_ _

_ 3

OK or ERR

 

ERR

 

None

 

I

M

B

G

_ _

_ 4

OK or ERR

 

ERR

Startup Image

Logo

 

I

M

S

I

_

_

_ 1

OK or ERR

 

ERR

Selection

Custom

 

I

M

S

I

_

_

_ 2

OK or ERR

 

ERR

 

None

 

I

M

S

I

_ _

_ 3

OK or ERR

 

ERR

Eco Mode

On

 

T

H

M

D

_ _ _ 1

OK or ERR

 

ERR

 

Off

 

T

H

M

D

_ _

_ 0

OK or ERR

 

ERR

Auto Search

On

 

I

N

S

E

_

_

_ 1

OK or ERR

 

ERR

 

Off

 

I

N

S

E

_

_

_ 0

OK or ERR

 

ERR

Auto Power Off

On

 

A

P

O

W

_ _

_ 1

OK or ERR

 

ERR

 

Off

 

A

P

O

W

_ _ _ 0

OK or ERR

 

ERR

Lamp Mode

Both Lamps

 

L

P

M

D

_ _

_ 0

OK or ERR

 

ERR

 

Lamp 1 Only

 

L

P

M

D

_ _

_ 1

OK or ERR

 

ERR

 

Lamp 2 Only

 

L

P

M

D

_ _

_ 2

OK or ERR

 

ERR

 

Equal Use

 

L

P

M

D

_ _

_ 3

OK or ERR

 

ERR

Lens Type

Type 1 (AH-55201)

L

N

T

Y

_

_

_ 1

OK or ERR

 

ERR

 

Type 2 (AH-55301)

L

N

T

Y

_

_

_ 2

OK or ERR

 

ERR

 

Type 3 (AH-55401)

L

N

T

Y

_

_

_ 3

OK or ERR

 

ERR

 

Type 4 (AH-55501)

L

N

T

Y

_

_

_ 4

OK or ERR

 

ERR

 

Type 5 (AH-55601)

L

N

T

Y

_

_

_ 5

OK or ERR

 

ERR

 

Type 6 (AH-55701)

L

N

T

Y

_

_

_ 6

OK or ERR

 

ERR

 

Type 7 (AH-55801)

L

N

T

Y

_

_

_ 7

OK or ERR

 

ERR

PRJ Mode

Reverse

On

I

M

R

E

_ _

_ 1

OK or ERR

 

ERR

 

 

Off

I

M

R

E

_ _

_ 0

OK or ERR

 

ERR

 

Invert

On

I

M

I

N

_

_

_ 1

OK or ERR

 

ERR

 

 

Off

I

M

I

N

_

_

_ 0

OK or ERR

 

ERR

Stack Setting

Normal

 

S

T

A

K

_

_

_ 0

OK or ERR

 

ERR

 

Master

 

S

T

A

K

_ _

_ 1

OK or ERR

 

ERR

 

Slave

 

S

T

A

K

_ _

_ 2

OK or ERR

 

ERR

Keylock Level

Normal

 

K

E

Y

L

_

_

_ 0

OK or ERR

 

ERR

 

Level A

 

K

E

Y

L

_ _

_ 1

OK or ERR

 

ERR

 

Level B

 

K

E

Y

L

_ _

_ 2

OK or ERR

 

ERR

Set Inputs

COMPUTER1

ON

R

A

S

I

_ _

_ 1

OK or ERR

 

ERR

 

 

OFF

R

A

S

I

_ _

_ 0

OK or ERR

 

ERR

 

COMPUTER2

ON

R

B

S

I

_ _ _ 1

OK or ERR

 

ERR

 

 

OFF

R

B

S

I

_ _

_ 0

OK or ERR

 

ERR

 

DVI

ON

R

C

S

I

_ _

_ 1

OK or ERR

 

ERR

 

 

OFF

R

C

S

I

_ _ _ 0

OK or ERR

 

ERR

 

HDMI

ON

R

D

S

I

_ _ _ 1

OK or ERR

 

ERR

 

 

OFF

R

D

S

I

_ _ _ 0

OK or ERR

 

ERR

 

VIDEO

ON

V

A

S

I

_ _ _ 1

OK or ERR

 

ERR

 

 

OFF

V

A

S

I

_ _

_ 0

OK or ERR

 

ERR

 

S-VIDEO

ON

V

B

S

I

_ _

_ 1

OK or ERR

 

ERR

 

 

OFF

V

B

S

I

_ _

_ 0

OK or ERR

 

ERR

Fan Mode

Normal

 

H

L

M

D

_ _

_ 0

OK or ERR

 

ERR

 

High

 

H

L

M

D

_ _

_ 1

OK or ERR

 

ERR

Auto Restart

On

 

A

R

E

S

_

_

_ 1

OK or ERR

 

ERR

 

Off

 

A

R

E

S

_ _

_ 0

OK or ERR

 

ERR

Monitor Out

Enable

 

M

O

U

T

_

_

_ 1

OK or ERR

 

ERR

 

Disable

 

M

O

U

T

_ _

_ 0

OK or ERR

 

ERR

LAN/RS232C

Enable

 

L

N

R

S

_ _

_ 1

OK or ERR

 

ERR

 

Disable

 

L

N

R

S

_

_

_ 0

OK or ERR

 

*5

Language

ENGLISH

 

M

E

L

A

_ _

_ 1

OK or ERR

 

ERR

 

DEUTSCH

 

M

E

L

A

_ _ _ 2

OK or ERR

 

ERR

 

ESPAÑOL

 

M

E

L

A

_ _ _ 3

OK or ERR

 

ERR

 

NEDERLANDS

 

M

E

L

A

_ _ _ 4

OK or ERR

 

ERR

 

FRANÇAIS

 

M

E

L

A

_ _ _ 5

OK or ERR

 

ERR

 

ITALIANO

 

M

E

L

A

_ _

_ 6

OK or ERR

 

ERR

 

SVENSKA

 

M

E

L

A

_ _ _ 7

OK or ERR

 

ERR

 

 

 

M

E

L

A

_ _ _ 8

OK or ERR

 

ERR

 

PORTUGUÊS

 

M

E

L

A

_ _ _ 9

OK or ERR

 

ERR

 

 

 

M

E

L

A

_ _ 1 0

OK or ERR

 

ERR

 

 

 

M

E

L

A

_ _ 1 1

OK or ERR

 

ERR

 

 

 

M

E

L

A

_ _ 1 2

OK or ERR

 

ERR

 

 

 

M

E

L

A

_ _ 1 3

OK or ERR

 

ERR

 

polski

 

M

E

L

A

_

_

1 4

OK or ERR

 

ERR

 

Türkçe

 

M

E

L

A

_ _

1 5

OK or ERR

 

ERR

 

 

 

M

E

L

A

_ _ 1 6

OK or ERR

 

ERR

All Reset *6

 

 

A

L

R

E

_

_

_ 1

OK or ERR

 

ERR

*1 Lamp Timer Reset command is available only in standby mode.

*2 Serial No. Check command is used to read out the 12 digits of serial No..

*3 For setting the projector name, send the commands in order of PJN1, PJN2 and PJN3. *4 Parameters of CLR Temp settings are as follows.

CLR Temp

_

Parameter

 

4500K

0

4

5

5500K

_

0

5

5

6500K

_

0

6

5

CLR Temp 7500K 8500K 9300K

_

Parameter

 

0

7

5

_

0

8

5

_

0

9

3

CLR Temp 10500K

_

Parameter 1 0

5

*5

Because the RS-232C function stops, the projector send no response code.

 

*6

See page 65 on the owner’s manual of the projector for the initialized items by using “All Reset”.

19

Image 19
Contents Setup Manual Standard Setup Front Projection Setting up the ScreenThrow Distance Screen Size and Projection DistanceF2.5, f=25.5-32 mm Signal Input Normal ModeF2.5, f=11.6 mm Fixed Wide Lens AH-55201F2.5, f=17.1 mm Fixed Wide Lens AH-55301F2.5, f=21.2-25.8 mm Wide-zoom Lens AH-55401F2.5, f=31.9-42.5 mm Tele-zoom Lens AH-55601F2.5, f=40.8-62.8 mm Tele-zoom Lens AH-55701F2.5, f=62.1-97.8 mm Tele-zoom Lens AH-55801Pin female connector Connecting Pin AssignmentsConnecting Pin Assignments Function and transmission codes Wired Remote Control Terminal SpecificationsSpecifications of wired remote control input Eiki remote control signal formatComputer control Communication conditions RS-232C Specifications and CommandsBasic format W R CommandsReturn PC RGB FAO CLR Temp Parameter 4500K 5500K 6500K Network settings on the computer Setting up the Projector Network EnvironmentConnecting the Pro- jector to a Computer Click Properties Setting an IP Address for the ComputerSetting up the Projector Network Environment Setting up a Network Connection for the Projector DNS Controlling the Projector via LAN Controlling the Projector Using Internet ExplorerControlling the Projector Confirming the ProjectorSetting the Security Setting and AdjustingSetting for Sending E-mail when an Error Occurs Making General Settings for the Network NetworkMail Recipient Settings InputPJS11234and press theEn- ter key Setting the Projector Using RS-232C or TelnetWhen Connecting Using RS-232C Input setup and press the Enter keyClickstartfrom theWindows desk- top and select Run When Connecting Using TelnetAdvanced Setup Menu Setup Menu Main MenuVView All Setting View Setting Detail ListSet Items Tings QQuit Unchanged Save Settings and QuitQuit without Saving Set SSave & QuitUser Name Setting IP Address SettingDefault Gateway Setting Subnet Mask SettingRS-232C Baud Rate Set Password SettingProjector Name Setting Dhcp Client SettingData Port Setting Disconnecting All ConnecSetting Auto Logout Time Entering Advanced Setup MenuCarrying out Network Ping Test Setting of Accept IP Ad- dressAccepting All IP Addresses Return to Default Settings Setting of Search PortReturn to Main Menu Stack Projection Turn off the both projectors Setting up the Stack ProjectionProjector 1 Master Projector 2 SlaveProjector Slave Projector MasterVideo Wall Projection Projector Setting up the Video Wall Projection BasicClick Video Wall on the menu Access one of the four projectors via Internet ExplorerSelect 1 X 1 on Division Click the assigning button Adjusting the Position Horizontally and VerticallyReturning to the Default Video Wall Setup Assigning the Projected Image on the Video Wall SetupVideo Wall Projection Setting up the Video Wall Projection Application Jectors as shown below Change the TCP/IP settings for the computer as shown belowClick Stack on the menu Select Slave on Stack Setting Click Stack on the menu Select Master on Stack SettingMake the IP address for each pro- jector as shown below Repeat the same procedure from the to 12 for the projector 3 Resetting the Lamp Timer of the Projector via LAN Close HyperTerminal Resetting the Lamp Timer of the Projector via LANWhen connecting the projector using serial-connection TroubleshootingTroubleshooting \ After the initialization, carry out setting again Units inches mm DimensionsWhen AH-55501 is installed When AH-55201 is installedWhen AH-55301 is installed When AH-55401 is installed

EIP-WX5000, EIP-WX5000L specifications

The Eiki EIP-WX5000 and EIP-WX5000L are cutting-edge projectors designed for high-performance presentations and immersive viewing experiences. Both models are equipped with advanced technologies that cater to the needs of professional environments, such as conference rooms, lecture halls, and large venues.

One of the standout features of the EIP-WX5000 series is its high brightness capability, with a luminosity of up to 5000 lumens. This ensures that images remain vibrant and visible even in well-lit environments, making it ideal for business presentations or educational settings where lighting conditions can vary. The WXGA resolution (1280 x 800 pixels) offers a sharp and clear image quality, enhancing the details and clarity of presentations and videos alike.

Both projectors leverage DLP technology, known for its durability and exceptional color accuracy. This technology enables a richer color palette and minimizes the risk of color decay over time, ensuring that users can rely on consistent performance. The EIP-WX5000 and EIP-WX5000L also feature a contrast ratio of up to 3000:1, providing deeper blacks and brighter whites, which accentuates the depth of the projected image.

Flexibility in installation is another appealing characteristic of these projectors. They come with a variety of lens options that support short throw, long throw, and ultra-short throw configurations. This adaptability makes them suitable for different room layouts and sizes, allowing users to set up the projector in a way that best suits their space.

Connectivity is a key component in today’s technology, and the EIP-WX5000 series does not disappoint. The projectors are equipped with multiple input options including HDMI, VGA, and USB, facilitating easy connections with a wide range of devices such as laptops, tablets, and Blu-ray players. The inclusion of built-in networking capabilities also allows for remote management and control via a web browser, enhancing convenience for IT departments.

For those concerned about noise levels, both models operate quietly, making them suitable for environments where distractions must be minimized. Additionally, they offer extensive lamp life, which contributes to lower maintenance costs over time.

In conclusion, the Eiki EIP-WX5000 and EIP-WX5000L projectors are engineered for excellence in presentation quality, adaptability, and ease of use, making them highly favorable for professional applications across various industries.