Intel 273561-003 manual Programming the Flash Memory, Scsi Termination

Page 15

Hardware Installation

Figure 2-2. Installing the IIR Controller into a Computer System

RAIDIOS-ENABLED PCI

2.3Programming the Flash Memory

The IIR controller normally comes ready to be installed into the computer motherboard immediately. However, you may need to reprogram the RAID firmware that is located in the flash memory of the IIR controller.

There are 2 options for programming the firmware, Firmware Update or Firmware Recovery. Use the Firmware Update procedure to overwrite the existing firmware with a new image (see Appendix A.1). Use the Firmware Recovery procedure to resolve problems with the flash memory, for example, if the current firmware programmed in the flash is unusable or if a previous firmware update was inadvertently interrupted (see Appendix A.2).

2.4SCSI Termination

Termination is a commonly overlooked requirement when connecting SCSI devices together. When these devices are connected together, the resulting set of devices is typically referred to as a SCSI bus. SCSI devices such as hard disks and tape drives must be terminated if they are the last physical devices at either end of the SCSI bus (if nothing else is actively terminating the end of the bus such as a terminator or backplane). If a device is inserted into the middle of the SCSI bus, then it (the device itself) should not be terminated. Only terminate each end of the bus. The modular RAID on motherboard (MROMB) design lowers cost by utilizing the SCSI controller and connectors that are integrated into the system’s motherboard. With MROMB, termination occurs on the host SCSI controller.

Hardware Installation and User’s Guide

15

Image 15
Contents Srcmru Hardware Installation and User’s Guide Contents Tables Intended Audience Using the User Documentation SetAbout This Guide Customer Support Contact InformationDocument Formats Product EMC Compliance Product Safety ComplianceRegulatory and Certification Information Product Regulatory ComplianceAustralia C-Tick Mark Culus Listing Marks CE Mark FCC Marking Class aCanada EMC Marking Class a Taiwan Bsmi Marking Class a Korea RRL MIC MarkElectromagnetic Compatibility Notices Japan Vcci Marking Class aFCC Verification Statement USA Ices 003 Canada CE Declaration of Conformity EuropeVcci Japan Bsmi Taiwan Installation Procedures About this ChapterComputer System Hardware Requirements IIR Controller Component Layout Installing the IIR ControllerScsi Termination Programming the Flash MemoryConfigurable I/O Controller Scsi Parameters Configurable Disk Drive Scsi ParametersConfigurable I/O Controller Scsi Parameters Configurable Disk Drive Scsi ParametersIIR Controller Hardware Features Hardware Architecture FeaturesElectrical Specifications Environmental Specifications Operating System SupportSupported Scsi Technology Supported Scsi Device Standards Supported Hard Drive TechnologyRAID Array Drive Roaming Optional Features RAID Controller Drive Maximum Limitations Srcmru Flash Memory Programming Firmware Update Procedure via Xrom StorConFigure A-1. Jumper Positions for Flash Update and Recovery Firmware Recovery Procedure via Flash Recovery Utility FRUFlash Memory Programming Flash Memory Programming Index