Hitachi CP-S845W If any abnormality occurs, Do not look directly at the lens when Lamp is lit

Page 4
outlet.
power
from the
Pull out the power plug
outlet.
power
from the
power plug
Pull out the

[Safety precaution]

Warning

If any abnormality occurs.

When there is an abnormal smell or smoke, if you use this unit as it is, this could cause a fire or electric shock, etc. When an abnormality is found, immediately turn off the power switch and pull out the power plug from the power outlet. Check that there is no smoke, etc., then contact your dealer to repair the unit. Do not repair it yourself as it is very dangerous.

Do not use this unit as it is after

trouble has occurred,

such as "No picture", "No sound", "Abnormal

sound", etc. This may cause a fire,

electric shock, etc. In this case immediately turn off the power switch and disconnect the power

plug, then contact your dealer to repair the unit.

Do not look directly at the lens when

the lamp is lit.

Do not look directly at the lens when the lamp is lit. Since a strong light

is used, it could damage you vision, etc. Especially pay attention if children are present.

Do not insert any foreign object.

Do not insert a metal or flammable

object inside through the ventilation holes, etc. This may cause a fire,

electric shock, etc.

• If foreign matter enters inside, turn the power switch off and disconnect

the power plug from the power outlet and contact your dealer. If you use as it is, it may cause a fire, electric shock, etc. Be careful especially if children could touch the unit.

If water, etc. enters inside the unit, turn off the power switch of the unit first and disconnect the power plug and then contact your dealer. If you use it as it is, it may cause a fire, electric shock, etc.

Do not install this unit in an unstable place.

Avoid placing it in an unstable place

Do not apply any shock.

If you drop this unit or if the cabinet is broken, turn off the power switch, disconnect the power plug and contact your dealer. If you use it as it is, it may cause a fire, electric shock, etc.

Pull out the power plug from the power outlet.

such as weak base, inclined floor, etc. This may cause it to drop or fall over, resulting in injury.

Do not open the cabinet.

Do not remodel this unit.

Do not remodel this unit. It may cause a fire, electric shock, etc.

Prohibition of disassembly

Do not open the cabinet. There are high voltage parts inside the cabinet

and this may cause an

Electric shock

Prohibition

electric shock. Ask your

hazard

of

 

 

disassembly

dealer to check inside and adjust and repair the unit.

Do not put a container, etc. with

liquid on this unit.

Do not put a vase, flowerpot, cosmetic container, medicine or

water and small metal objects on this unit. If liquid spills and enter inside the unit, it may cause a fire, electric shock, etc.

Do not use this in a bathroom, etc.

Do not use this unit in a bathroom,

etc. This may cause a fire, electric

shock, etc.

Do not use near water

4

Do not use power supplies other

than that specified.

Do not use this unit with a power voltage other than specified power

supply voltage. It may cause a fire, electric shock, etc.

Downloaded from www.Manualslib.com manuals search engine

Image 4
Contents Features ContentsOutline Operating GuideAbout Trademarks Video signal cables Power cordBefore use Instructions to UsersDo not look directly at the lens when Lamp is lit Do not install this unit in an unstable placeDo not use power supplies other Than that specified If any abnormality occursDo not stare directly into the laser aperture LASER-STRAHLUNG PlaceCleaning Handle the power cord carefullyUse of batteries When you are not going to use for a Clean inside the unit at least once two yearsDo not place this unit where it gets hot VolumeCleaning the lens Cleaning the cabinetContents of shipping box Names and functions of each partRemote control sensor Main Power switch AC in socketVideo input terminal RGB input terminalRemote control transmitter How to insert batteries Names and functions of each partExample of the projector and screen installation InstallationHow to use foot adjusters Basic operations On indicator will light up orangeTo project the picture To turn off the power Indicator lights up orangeStandby mode PLUG&PLAYFreeze Function Magnifying FunctionAdjustments and functions To return to the initial settingMemory function On-screen menus are displayed on the screenSET UP How to use the SET UP menuBar display items VOLUME, Bright etc Numerical display items V POSIT, H Posit etcAUTO-adjustment AUTO-adjustment Confirm ScreenDuring AUTO-adjustment Adjustment Item Details of adjustmentImage The menu Image serves of the picture inversion OPTMenu OPT. allows you to control communication function etc Connection to the video signal terminals Connection to the RGB signal terminalExample of computer signal Resolution Standard Display Dots KHz TypeComputer/signal Horizontal Timing µs Initial set signalsComputer/signal Vertical Timing lines Connection to the control signal terminal Control signal terminalADB Mac mouse PS/2 mouseSerial mouse Control command table Control command tableCommunication RS232C cable OptionCommand data Procedure of getting the Projector status Procedure of setting the Projector statusProcedure of default setting the Projector status Example of command errorExample of system setup Connecting various equipmentAC Inlet Computer Note type ComputerDesk typeAir filter Filter cover Cleaning the air filterDo not use with removed air filter Remove the lamp cover Loosen two screws and pull the handle to remove LampIf it is probable that the lamp has exploded Loosen a screw and remove the coverInstall the lamp cover and fix it using screws Reset the lamp timeLamp MalfunctioningIndicator display Message tableOn-screen display ActionWhen you think something wrong Dimension diagram Product name Liquid crystal projector Model name CP-S845WRCA Jack terminal Input terminal Input/Output RCA Jack terminal Terminal
Related manuals
Manual 34 pages 52.32 Kb