Hitachi 1000 manual Redundant Cooling Fan Modules, Top view and cooling fan modules numbers

Page 38

power redundancy, it boots the system after issuing a warning by illuminating the Warning LED. Hot swapping is not possible in the absence of redundant power.

Redundant Cooling Fan Modules

The Cooling Fan Modules cool the system with variable speed fans, and are installed redundantly, as illustrated in Figure 27. The fans cool the system by pulling air from the front of the chassis to the back. The modules can be hot-plugged, enabling a failed Cooling Fan Module to be replaced without disrupting system operations. Cooling Fan Modules support the following functions:

Control rotation

Detect abnormal rotation

Indicate the faulty location with LEDs

Built-in fuse

Cooling fan 1

Server blade slot No.

Cooling fan 0

PCI slot No.

0

0

1

1

2

2

3

4

 

5

3

6

 

7

 

8

4

9

 

10

5

11

 

12

6

13

14

7

15

 

Cooling fan 2

Cooling fan 3

Figure 27. Top view and cooling fan modules numbers

38 BladeSymphony 1000 Architecture White Paper

www.hitachi.com

Image 38
Contents BladeSymphony 1000 Architecture Table of Contents Introducing BladeSymphony IntroductionExecutive Summary Enterprise-Class Capabilities BladeSymphony 1000 front viewData Center Applications System Architecture Overview Front Intel Itanium Server Blade features Intel Itanium Server BladeTwo ports per partition SpecificationsBackplane Node link for Three interconnect ports Interface Fast Ethernet Two100Base/10Base ports LAN manage MentIntel Itanium Processor 9100 Series FW ROM AtmelCache Hyper-Threading TechnologyIntel VT Virtualization Technology Demand Based SwitchingHitachi Node Controller Bus throughput from the Hitachi Node ControllerBaseboard Management Controller Memory SystemSMP Capabilities Hitachi Node Controller connects multiple server blades SMP Configuration Options Numa ArchitectureFull interleave mode and non-interleave mode Intel Itanium I/O Expansion Module L3 Cache Copy TagEBS Chassis Intel Xeon Server Blade Intel Xeon Server Blade componentsIntel Xeon 5200 Dual Core Processors Microsoft Windows Server 2003 SP2, Enterprise x64 EditionIntel Xeon 5400 Quad Core Processors FB-DIMM AdvantagesOnline Spare Memory Online spare memory supported configurationsAdvanced ECC Memory Mirroring Memory mirroringOn-Module Storage PCI-X I/O Module Sub SystemModules PCIe I/O Module Embedded Fibre Channel Switch ModulePCI-X I/O Module connector types PCIe I/O Module Combo CardFiber channel switch close-up Total 8 modules mountable Embedded Fibre Channel Switch Module components FCSW, Ipfc RFC, FCAL2, FcphFC-HBA + Gigabit Ethernet Combo Card LANManagement Software Hitachi FC Controller FC-HBA functionsEmbedded Gigabit Ethernet Switch Scsi Hard Drive Modules Connection configuration for HDD Modules Chassis, Power, and Cooling Chassis specificationsRedundant Power Modules Module ConnectionsRedundant Cooling Fan Modules Top view and cooling fan modules numbersReliability features Reliability and Serviceability FeaturesReliability Features Serviceability Features Switch & Management ModuleSwitch & Management Module components NV SramBase Management Controller BMC Console Functions OS ConsoleSVP Console Remote ConsoleOperating System Support Management SoftwareBladeSymphony Management Suite +1 or N+M Cold Standby Fail-over Operations ManagementDeployment Manager Rack Management Remote ManagementNetwork Management Asset ManagementHigh CPU Performance and Features VirtageHigh I/O Performance Dedicated ModeShared Mode Integrated System Management for Virtual Machines Fiber Channel VirtualizationShared/Virtual NIC Functions Summary For More InformationSierra Point Parkway