NEC N8406-022 manual SNMPv3 Group configuration, SNMPv3 Community Table configuration

Page 68

Table 65 View-based Access Control Configuration commands

Command

Description

show snmp-server access

Displays the View-based Access Control configuration.

<1-32>

Command mode: All

SNMPv3 Group configuration

The following table describes the SNMPv3 Group Configuration commands.

Table 66 SNMPv3 Group Configuration commands

Command

Description

snmp-server group <1-16>

Defines the security model.

security {usmsnmpv1snmpv2}

Command mode: Global configuration

snmp-server group <1-16>

Sets the user name. The user name can have a maximum of 32

user-name<1-32 characters>

characters.

 

Command mode: Global configuration

snmp-server group <1-16

The name for the access group. The group name can have a maximum

group-name<1-32 characters>

of 32 characters.

 

Command mode: Global configuration

no snmp-server group <1-16>

Deletes the vacmSecurityToGroup entry.

 

Command mode: Global configuration

show snmp-server group <1-

Displays the current vacmSecurityToGroup configuration.

16>

Command mode: All

SNMPv3 Community Table configuration

These commands are used for configuring the community table entry. The configured entry is stored in the community table list in the SNMP engine. This table is used to configure community strings in the Local Configuration Datastore (LCD) of SNMP engine.

The following table describes the SNMPv3 Community Table Configuration commands.

Table 67 SNMPv3 Community Table Configuration commands

Command

Description

snmp-server community <1-16>

Configures the unique index value of a row in this table. The index can

index <1-32 characters>

have a maximum of 32 characters.

 

Command mode: Global configuration

snmp-server community <1-16>

Defines the name, up to 32 characters.

name <1-32 characters>

Command mode: Global configuration

snmp-server community <1-16>

Defines a readable 32 character string that represents the corresponding

user-name<1-32 characters>

value of an SNMP community name in a security model.

 

Command mode: Global configuration

snmp-server community <1-16>tag <1-255 characters>

Configures a tag of up to 255 characters maximum. This tag specifies a set of transport endpoints to which a command responder application sends an SNMP trap.

Command mode: Global configuration

no snmp-server community

Deletes the community table entry.

<1-16>

Command mode: Global configuration

show snmp-server community

Displays the community table configuration.

<1-16>

Command mode: All

Configuration Commands 68

Image 68
Contents N8406-022 1Gb Intelligent L2 Switch Page Contents Statistics commands Operations Commands Connecting to the switch Iscli ReferenceIntroduction Additional referencesSetting an IP address Telnet 1Gb Intelligent L2 Switch IP addressEstablishing a Telnet connection Establishing an SSH connectionAccessing the switch # ssh user@1Gb Intelligent L2 Switch IP addressIdle timeout Typographical conventionsPing IP address Show portchannel 1-12hashinformationShow ip interface Show spanning-tree stpIscli basics Accessing the IscliIscli Command Modes Global commands Command line interface shortcuts Command abbreviationSwitchconfig# spanning-tree stp 1 bridge hello Switchconfig# sp stp 1 br hInformation Commands System Information commands SNMPv3 Information commandsSNMPv3 USM User Table information SNMPv3 View Table informationUser Name ProtocolSNMPv3 Access Table information View NameGroup Name PrefixSNMPv3 Group Table information SNMPv3 Community Table informationSec Model Index Name User Name Tag Trap1 Public V1v2only V1v2trapSec Level SNMPv3 Target Address Table informationSNMPv3 Target Parameters Table information SNMPv3 Notify Table information NameTag V1v2trapv1v2trapShow snmp-server v3 Command mode All SNMPv3 dumpSystem information System user information Usernames Enabled Oper Disabled Admin Always EnabledShow recent syslog messages Layer 2 information FDB information commands Show all FDB informationSpanning Tree information Show spanning-tree stp 1-32informationRapid Spanning Tree and Multiple Spanning Tree information Priority bridge Designated bridgeCommon Internal Spanning Tree information Desg 8000-000342fa3b80 8001 P2P, Edge 128 2000Desg 8000-000342fa3b80 8002 128 2000 128 2000Discarding DISC, Learning LRN, Forwarding FWD, or Disabled DSBCist Root Vlan information Trunk group 1, Enabled port state STG 1 forwardingTrunk group information Layer 3 information ARP informationShow layer3 information Command mode All IP informationShow all ARP entry information ARP address list informationIgmp multicast group information Igmp multicast router port informationRmon Information Rmon history informationInterval Rmon alarm informationShow rmon alarm Rmon event information Show rmon eventLink status information VLANs Port informationPort Tag Rmon Pvid Uplink Failure Detection information Show geaport Command mode AllLogical Port to GEA Port mapping Information dump Statistics commands Port StatisticsBridging statistics Ethernet statisticsDot3StatsAlignmentErrors Dot3StatsFCSErrorsDot3StatsInternalMacTransmitError Dot3StatsSingleCollisionFramesInterface statistics Internet Protocol IP statistics Show interface gigabitethernet port number ip-countersLayer 2 statistics Link statisticsFDB statistics Show interface gigabitethernet port number link-countersLayer 3 statistics IP statisticsARP statistics ARP statistics ArpEntriesCur ArpEntriesHighWaterDNS statistics DnsInRequests DnsOutRequests DnsBadRequests DNS statisticsIcmp statistics TCP statistics UDP statistics Management Processor statistics Igmp Multicast Group statisticsShow mp tcp-block Show mp udp-block161 10ad41e8/10ad5790All UDP allocated control blocks Listen Snmp statistics Show snmp-server counters Command mode All except User ExecCPU statistics Decoding Snmp messages received Show ntp counters Command mode All NTP statisticsUplink Failure Detection statistics Statistics dumpConfiguration Commands Saving the configurationSystem configuration Viewing and saving changesSystem host log configuration Secure Shell Server configuration Radius server configuration TACACS+ server configuration NTP server configuration System Snmp configuration SNMPv3 configuration User Security Model configuration Privacy-password passwordPrivacy-protocol desnone No snmp-server userSNMPv3 View configuration View-based Access Control Model configurationSNMPv3 Group configuration SNMPv3 Community Table configurationSNMPv3 Target Address Table configuration SNMPv3 Target Parameters Table configurationManagement Networks configuration SNMPv3 Notify Table configurationSystem Access configuration User Access Control configuration User ID configurationHttps Access configuration Port configuration Temporarily disabling a portLayer 2 configuration Port link configurationSpanning-tree mrst Mode Spanning-tree mrst EnableSpanning-tree mstp NameCommon Internal Spanning Tree configuration Cist bridge configurationCist port configuration Spanning Tree configuration Bridge Spanning Tree configuration Spanning Tree port configuration Static FDB configuration Forwarding Database configurationTrunk configuration Layer 3 configuration Vlan configurationIP interface configuration Default Gateway configurationIgmp snooping configuration Address Resolution Protocol configurationIgmp configuration Igmp static multicast router configuration Igmp filtering configurationIgmp filter definition Domain Name System configurationIgmp filtering port configuration Rmon event configuration Remote Monitoring configurationRmon history configuration Rmon alarm configuration Port-based port mirroring Uplink Failure Detection configurationPort mirroring Configuration Dump Failure Detection Pair configurationLink to Monitor configuration Link to Disable configurationSaving the active switch configuration Restoring the active switch configurationOperations Commands Operations-level port optionsBoot Options Updating the switch software imageDownloading new software to the switch Router# copy tftp image1image2boot-imageUploading a software image from the switch Routerconfig# boot image image1image2Switch# copy image1image2boot-image tftp Selecting a software image to runAccessing the AOS CLI Selecting a configuration blockResetting the switch Forwarding Database maintenance Maintenance CommandsSystem maintenance ARP cache maintenance Debugging optionsUuencode flash dump Igmp Snooping maintenanceIgmp Mrouter maintenance Panic command Switch# copy flash-dump tftp server filenameSwitch# clear flash-dump Tftp system dump putUnscheduled system dumps Index
Related manuals
Manual 62 pages 46.6 Kb

N8406-022 specifications

The NEC N8406-022 is a robust and versatile networking device designed primarily for organizations requiring high-performance connectivity solutions. As part of NEC's extensive portfolio of networking equipment, the N8406-022 is engineered to address the demands of modern enterprise environments, ensuring seamless communication and data processing capabilities.

One of the key features of the N8406-022 is its multi-layer switching functionality. This device supports Layer 2 and Layer 3 switching, allowing for efficient data routing and reducing latency within local area networks (LANs). This capability is particularly beneficial for businesses that rely on real-time data access and transfer, such as those in financial services, media, and telecommunications.

The N8406-022 is equipped with advanced Quality of Service (QoS) features that help prioritize critical network traffic. This means that voice and video data packets can be given precedence over less time-sensitive information, ensuring that essential communication remains clear and uninterrupted. This is crucial for organizations leveraging VoIP and video conferencing solutions.

In terms of connectivity, the NEC N8406-022 offers a variety of ports, including multiple Gigabit Ethernet ports, which facilitate high-speed data transfer and enable seamless integration into existing network infrastructures. The device may also include 10 Gigabit SFP+ ports, providing the flexibility for high-capacity uplinks to support bandwidth-intensive applications and storage solutions.

Security is another focal point of the NEC N8406-022, with integrated features such as VLAN support, access control lists (ACLs), and port security measures. These capabilities protect sensitive data from unauthorized access and ensure that only legitimate users and devices can connect to the network.

Moreover, the N8406-022 often incorporates advanced energy-efficient technologies that minimize power consumption without compromising performance. This not only contributes to operational cost savings but also supports organizations in their sustainability efforts.

With its combination of performance, security, and energy efficiency, the NEC N8406-022 stands out as a reliable networking solution suitable for a wide range of enterprises looking to enhance their connectivity and operational efficiency. Whether deployed in data centers or as part of a corporate network, this device is built to meet the evolving demands of today’s digital landscape.