NEC N8406-022 manual System Snmp configuration

Page 64

System SNMP configuration

The switch software supports SNMP-based network management. In SNMP model of network management, a management station (client/manager) accesses a set of variables known as MIBs (Management Information Base) provided by the managed device (agent). If you are running an SNMP network management station on your network, you can manage the switch using the following standard SNMP MIBs:

MIB II (RFC 1213)

Ethernet MIB (RFC 1643)

Bridge MIB (RFC 1493)

An SNMP agent is a software process on the managed device that listens on UDP port 161 for SNMP messages. Each SNMP message sent to the agent contains a list of management objects to retrieve or to modify.

SNMP parameters that can be modified include:

System name

System location

System contact

Use of the SNMP system authentication trap function

Read community string

Write community string

The following table describes the System SNMP Configuration commands. The following sections provide more detailed information and commands.

Table 61 System SNMP Configuration commands

Command

Description

hostname <1-64

Configures the name for the system. The name can have a maximum of 64

characters>

characters.

 

Command mode: Global configuration

snmp-server location

Configures the name of the system location. The location can have a maximum of 64

<1-64 characters>

characters.

 

Command mode: Global configuration

snmp-server contact

Configures the name of the system contact. The contact can have a maximum of 64

<1-64 characters>

characters.

 

Command mode: Global configuration

snmp-server read- community <1-32

characters>

Configures the SNMP read community string. The read community string controls SNMP “get” access to the switch. It can have a maximum of 32 characters. The default read community string is public.

Command mode: Global configuration

snmp-server write- community <1-32

characters>

Configures the SNMP write community string. The write community string controls SNMP “set” and “get” access to the switch. It can have a maximum of 32 characters. The default write community string is private.

Command mode: Global configuration

snmp-server timeout

Sets the timeout value for the SNMP state machine. The range is 1-30 minutes. The

<1-30>

default value is 5 minutes.

 

Command mode: Global configuration

[no] snmp-server authentication-trap enable

Enables or disables the use of the system authentication trap facility. The default setting is disabled.

Command mode: Global configuration

[no] snmp-server link-

Enables or disables the sending of SNMP link up and link down traps. The default

trap

setting is enabled.

 

Command mode: Global configuration

[no] snmp-server ufd-

Enables or disables the sending of Uplink Failure Detection traps. The default setting

trap

is disabled.

 

Command mode: Global configuration

show snmp-server

Displays the current SNMP configuration.

 

Command mode: All

Configuration Commands 64

Image 64
Contents N8406-022 1Gb Intelligent L2 Switch Page Contents Statistics commands Operations Commands Connecting to the switch Iscli ReferenceIntroduction Additional referencesSetting an IP address Telnet 1Gb Intelligent L2 Switch IP addressEstablishing a Telnet connection Establishing an SSH connectionAccessing the switch # ssh user@1Gb Intelligent L2 Switch IP addressIdle timeout Typographical conventionsPing IP address Show portchannel 1-12hashinformationShow ip interface Show spanning-tree stpIscli Command Modes Accessing the IscliIscli basics Global commands Command line interface shortcuts Command abbreviationSwitchconfig# spanning-tree stp 1 bridge hello Switchconfig# sp stp 1 br hInformation Commands System Information commands SNMPv3 Information commandsSNMPv3 USM User Table information SNMPv3 View Table informationUser Name ProtocolSNMPv3 Access Table information View NameGroup Name PrefixSNMPv3 Group Table information SNMPv3 Community Table informationSec Model Index Name User Name Tag Trap1 Public V1v2only V1v2trapSNMPv3 Target Parameters Table information SNMPv3 Target Address Table informationSec Level SNMPv3 Notify Table information NameTag V1v2trapv1v2trapShow snmp-server v3 Command mode All SNMPv3 dumpSystem information Show recent syslog messages Usernames Enabled Oper Disabled Admin Always EnabledSystem user information Layer 2 information FDB information commands Show all FDB informationSpanning Tree information Show spanning-tree stp 1-32informationRapid Spanning Tree and Multiple Spanning Tree information Priority bridge Designated bridgeCommon Internal Spanning Tree information Desg 8000-000342fa3b80 8001 P2P, Edge 128 2000Desg 8000-000342fa3b80 8002 128 2000 128 2000Cist Root Disabled DSBDiscarding DISC, Learning LRN, Forwarding FWD, or Trunk group information Trunk group 1, Enabled port state STG 1 forwardingVlan information Layer 3 information ARP informationShow layer3 information Command mode All IP informationShow all ARP entry information ARP address list informationIgmp multicast group information Igmp multicast router port informationRmon Information Rmon history informationShow rmon alarm Rmon alarm informationInterval Rmon event information Show rmon eventLink status information Port Tag Rmon Pvid Port informationVLANs Logical Port to GEA Port mapping Show geaport Command mode AllUplink Failure Detection information Information dump Statistics commands Port StatisticsBridging statistics Ethernet statisticsDot3StatsAlignmentErrors Dot3StatsFCSErrorsDot3StatsInternalMacTransmitError Dot3StatsSingleCollisionFramesInterface statistics Internet Protocol IP statistics Show interface gigabitethernet port number ip-countersLayer 2 statistics Link statisticsFDB statistics Show interface gigabitethernet port number link-countersLayer 3 statistics IP statisticsARP statistics ARP statistics ArpEntriesCur ArpEntriesHighWaterIcmp statistics DNS statisticsDNS statistics DnsInRequests DnsOutRequests DnsBadRequests TCP statistics UDP statistics Management Processor statistics Igmp Multicast Group statisticsShow mp tcp-block Show mp udp-blockAll UDP allocated control blocks Listen 10ad41e8/10ad5790161 CPU statistics Show snmp-server counters Command mode All except User ExecSnmp statistics Decoding Snmp messages received Show ntp counters Command mode All NTP statisticsUplink Failure Detection statistics Statistics dumpConfiguration Commands Saving the configurationSystem configuration Viewing and saving changesSystem host log configuration Secure Shell Server configuration Radius server configuration TACACS+ server configuration NTP server configuration System Snmp configuration SNMPv3 configuration User Security Model configuration Privacy-password passwordPrivacy-protocol desnone No snmp-server userSNMPv3 View configuration View-based Access Control Model configurationSNMPv3 Group configuration SNMPv3 Community Table configurationSNMPv3 Target Address Table configuration SNMPv3 Target Parameters Table configurationSystem Access configuration SNMPv3 Notify Table configurationManagement Networks configuration User Access Control configuration User ID configurationHttps Access configuration Port configuration Temporarily disabling a portLayer 2 configuration Port link configurationSpanning-tree mrst Mode Spanning-tree mrst EnableSpanning-tree mstp NameCommon Internal Spanning Tree configuration Cist bridge configurationCist port configuration Spanning Tree configuration Bridge Spanning Tree configuration Spanning Tree port configuration Trunk configuration Forwarding Database configurationStatic FDB configuration Layer 3 configuration Vlan configurationIP interface configuration Default Gateway configurationIgmp configuration Address Resolution Protocol configurationIgmp snooping configuration Igmp static multicast router configuration Igmp filtering configurationIgmp filtering port configuration Domain Name System configurationIgmp filter definition Rmon history configuration Remote Monitoring configurationRmon event configuration Rmon alarm configuration Port mirroring Uplink Failure Detection configurationPort-based port mirroring Configuration Dump Failure Detection Pair configurationLink to Monitor configuration Link to Disable configurationSaving the active switch configuration Restoring the active switch configurationOperations Commands Operations-level port optionsBoot Options Updating the switch software imageDownloading new software to the switch Router# copy tftp image1image2boot-imageUploading a software image from the switch Routerconfig# boot image image1image2Switch# copy image1image2boot-image tftp Selecting a software image to runResetting the switch Selecting a configuration blockAccessing the AOS CLI System maintenance Maintenance CommandsForwarding Database maintenance ARP cache maintenance Debugging optionsIgmp Mrouter maintenance Igmp Snooping maintenanceUuencode flash dump Panic command Switch# copy flash-dump tftp server filenameSwitch# clear flash-dump Tftp system dump putUnscheduled system dumps Index
Related manuals
Manual 62 pages 46.6 Kb

N8406-022 specifications

The NEC N8406-022 is a robust and versatile networking device designed primarily for organizations requiring high-performance connectivity solutions. As part of NEC's extensive portfolio of networking equipment, the N8406-022 is engineered to address the demands of modern enterprise environments, ensuring seamless communication and data processing capabilities.

One of the key features of the N8406-022 is its multi-layer switching functionality. This device supports Layer 2 and Layer 3 switching, allowing for efficient data routing and reducing latency within local area networks (LANs). This capability is particularly beneficial for businesses that rely on real-time data access and transfer, such as those in financial services, media, and telecommunications.

The N8406-022 is equipped with advanced Quality of Service (QoS) features that help prioritize critical network traffic. This means that voice and video data packets can be given precedence over less time-sensitive information, ensuring that essential communication remains clear and uninterrupted. This is crucial for organizations leveraging VoIP and video conferencing solutions.

In terms of connectivity, the NEC N8406-022 offers a variety of ports, including multiple Gigabit Ethernet ports, which facilitate high-speed data transfer and enable seamless integration into existing network infrastructures. The device may also include 10 Gigabit SFP+ ports, providing the flexibility for high-capacity uplinks to support bandwidth-intensive applications and storage solutions.

Security is another focal point of the NEC N8406-022, with integrated features such as VLAN support, access control lists (ACLs), and port security measures. These capabilities protect sensitive data from unauthorized access and ensure that only legitimate users and devices can connect to the network.

Moreover, the N8406-022 often incorporates advanced energy-efficient technologies that minimize power consumption without compromising performance. This not only contributes to operational cost savings but also supports organizations in their sustainability efforts.

With its combination of performance, security, and energy efficiency, the NEC N8406-022 stands out as a reliable networking solution suitable for a wide range of enterprises looking to enhance their connectivity and operational efficiency. Whether deployed in data centers or as part of a corporate network, this device is built to meet the evolving demands of today’s digital landscape.