Failure Detection Pair configuration

Use these commands to configure a Failure Detection Pair, which consists of one Link to Monitor (LtM) and one Link to Disable (LtD). When the switch detects a failure on the LtM, it automatically disables the ports in the LtD.

The following table describes the Failure Detection Pair (FDP) configuration commands.

Table 107 Failure Detection Pair Configuration commands

Command

Description

ufd fdp enable

Enables the FDP Parameters.

 

Command mode: Global configuration

no ufd fdp enable

Disables the FDP Parameters.

 

Command mode: Global configuration

Link to Monitor configuration

The following table describes the Link to Monitor (LtM) commands. The LtM can consist of only one uplink port (ports 20-24) or a single trunk containing only uplink ports.

Table 108 Link to Monitor commands

Command

Description

ufd fdp ltm port <port

Adds a port to the LtM. Only uplink ports (20-24) are allowed in the LtM.

number>

Command mode: Global configuration

no ufd fdp ltm port <port

Removes a port from the LtM.

number>

Command mode: Global configuration

ufd fdp ltm trunk <1-12>

Adds a trunk group to the LtM. The LtM trunk group can contain only uplink

 

ports (20-24).

 

Command mode: Global configuration

no ufd fdp ltm trunk <1-12>

Removes a trunk group from the LtM.

 

Command mode: Global configuration

Link to Disable configuration

The following table describes the Link to Disable (LtD) commands. The LtD can consist of any mix of downlink ports (ports 1-16) and trunk groups that contain only downlink ports.

Table 109 Link to Disable commands

Command

Description

ufd fdp ltd port <port

Adds a port to the current LtD group. Only downlink ports (1-16) are allowed in

number>

the LtD.

 

Command mode: Global configuration

no ufd fdp ltd port <port

Removes a port from the current LtD group.

number>

Command mode: Global configuration

ufd fdp ltd portchannel

Adds a trunk group to the current LtD group. LtD trunk groups can contain only

<1-12>

downlink ports (1-16).

 

Command mode: Global configuration

no ufd fdp ltd

Removes a trunk group from the current LtD group.

portchannel <1-12>

Command mode: Global configuration

Configuration Dump

The dump program writes the current switch configuration to the terminal screen. To start the dump program, at the prompt, enter:

Switch(config)# show running-config

The configuration is displayed with parameters that have been changed from the default values. The screen display can be captured, edited, and placed in a script file, which can be used to configure other switches. Paste the configuration commands from the script file at the command line prompt of the switch. The active configuration can also be saved or loaded via TFTP.

Configuration Commands 90

Image 90
Contents N8406-022 1Gb Intelligent L2 Switch Page Contents Statistics commands Operations Commands Introduction Connecting to the switchIscli Reference Additional referencesEstablishing a Telnet connection Setting an IP addressTelnet 1Gb Intelligent L2 Switch IP address Establishing an SSH connectionAccessing the switch # ssh user@1Gb Intelligent L2 Switch IP addressPing IP address Idle timeoutTypographical conventions Show portchannel 1-12hashinformationShow ip interface Show spanning-tree stpAccessing the Iscli Iscli Command ModesIscli basics Global commands Switchconfig# spanning-tree stp 1 bridge hello Command line interface shortcutsCommand abbreviation Switchconfig# sp stp 1 br hInformation Commands System Information commands SNMPv3 Information commandsUser Name SNMPv3 USM User Table informationSNMPv3 View Table information ProtocolGroup Name SNMPv3 Access Table informationView Name PrefixSec Model SNMPv3 Group Table informationSNMPv3 Community Table information Index Name User Name Tag Trap1 Public V1v2only V1v2trapSNMPv3 Target Address Table information SNMPv3 Target Parameters Table informationSec Level SNMPv3 Notify Table information NameTag V1v2trapv1v2trapShow snmp-server v3 Command mode All SNMPv3 dumpSystem information Usernames Enabled Oper Disabled Admin Always Enabled Show recent syslog messagesSystem user information Layer 2 information FDB information commands Show all FDB informationSpanning Tree information Show spanning-tree stp 1-32informationRapid Spanning Tree and Multiple Spanning Tree information Priority bridge Designated bridgeDesg 8000-000342fa3b80 8002 128 2000 Common Internal Spanning Tree informationDesg 8000-000342fa3b80 8001 P2P, Edge 128 2000 128 2000Disabled DSB Cist RootDiscarding DISC, Learning LRN, Forwarding FWD, or Trunk group 1, Enabled port state STG 1 forwarding Trunk group informationVlan information Layer 3 information ARP informationShow all ARP entry information Show layer3 information Command mode AllIP information ARP address list informationRmon Information Igmp multicast group informationIgmp multicast router port information Rmon history informationRmon alarm information Show rmon alarmInterval Rmon event information Show rmon eventLink status information Port information Port Tag Rmon PvidVLANs Show geaport Command mode All Logical Port to GEA Port mappingUplink Failure Detection information Information dump Statistics commands Port StatisticsBridging statistics Ethernet statisticsDot3StatsInternalMacTransmitError Dot3StatsAlignmentErrorsDot3StatsFCSErrors Dot3StatsSingleCollisionFramesInterface statistics Internet Protocol IP statistics Show interface gigabitethernet port number ip-countersFDB statistics Layer 2 statisticsLink statistics Show interface gigabitethernet port number link-countersLayer 3 statistics IP statisticsARP statistics ARP statistics ArpEntriesCur ArpEntriesHighWaterDNS statistics Icmp statisticsDNS statistics DnsInRequests DnsOutRequests DnsBadRequests TCP statistics UDP statistics Show mp tcp-block Management Processor statisticsIgmp Multicast Group statistics Show mp udp-block10ad41e8/10ad5790 All UDP allocated control blocks Listen161 Show snmp-server counters Command mode All except User Exec CPU statisticsSnmp statistics Decoding Snmp messages received Show ntp counters Command mode All NTP statisticsUplink Failure Detection statistics Statistics dumpSystem configuration Configuration CommandsSaving the configuration Viewing and saving changesSystem host log configuration Secure Shell Server configuration Radius server configuration TACACS+ server configuration NTP server configuration System Snmp configuration SNMPv3 configuration Privacy-protocol desnone User Security Model configurationPrivacy-password password No snmp-server userSNMPv3 View configuration View-based Access Control Model configurationSNMPv3 Group configuration SNMPv3 Community Table configurationSNMPv3 Target Address Table configuration SNMPv3 Target Parameters Table configurationSNMPv3 Notify Table configuration System Access configurationManagement Networks configuration User Access Control configuration User ID configurationHttps Access configuration Port configuration Temporarily disabling a portLayer 2 configuration Port link configurationSpanning-tree mstp Spanning-tree mrst ModeSpanning-tree mrst Enable NameCommon Internal Spanning Tree configuration Cist bridge configurationCist port configuration Spanning Tree configuration Bridge Spanning Tree configuration Spanning Tree port configuration Forwarding Database configuration Trunk configurationStatic FDB configuration Layer 3 configuration Vlan configurationIP interface configuration Default Gateway configurationAddress Resolution Protocol configuration Igmp configurationIgmp snooping configuration Igmp static multicast router configuration Igmp filtering configurationDomain Name System configuration Igmp filtering port configurationIgmp filter definition Remote Monitoring configuration Rmon history configurationRmon event configuration Rmon alarm configuration Uplink Failure Detection configuration Port mirroringPort-based port mirroring Link to Monitor configuration Configuration DumpFailure Detection Pair configuration Link to Disable configurationSaving the active switch configuration Restoring the active switch configurationOperations Commands Operations-level port optionsDownloading new software to the switch Boot OptionsUpdating the switch software image Router# copy tftp image1image2boot-imageSwitch# copy image1image2boot-image tftp Uploading a software image from the switchRouterconfig# boot image image1image2 Selecting a software image to runSelecting a configuration block Resetting the switchAccessing the AOS CLI Maintenance Commands System maintenanceForwarding Database maintenance ARP cache maintenance Debugging optionsIgmp Snooping maintenance Igmp Mrouter maintenanceUuencode flash dump Switch# clear flash-dump Panic commandSwitch# copy flash-dump tftp server filename Tftp system dump putUnscheduled system dumps Index
Related manuals
Manual 62 pages 46.6 Kb

N8406-022 specifications

The NEC N8406-022 is a robust and versatile networking device designed primarily for organizations requiring high-performance connectivity solutions. As part of NEC's extensive portfolio of networking equipment, the N8406-022 is engineered to address the demands of modern enterprise environments, ensuring seamless communication and data processing capabilities.

One of the key features of the N8406-022 is its multi-layer switching functionality. This device supports Layer 2 and Layer 3 switching, allowing for efficient data routing and reducing latency within local area networks (LANs). This capability is particularly beneficial for businesses that rely on real-time data access and transfer, such as those in financial services, media, and telecommunications.

The N8406-022 is equipped with advanced Quality of Service (QoS) features that help prioritize critical network traffic. This means that voice and video data packets can be given precedence over less time-sensitive information, ensuring that essential communication remains clear and uninterrupted. This is crucial for organizations leveraging VoIP and video conferencing solutions.

In terms of connectivity, the NEC N8406-022 offers a variety of ports, including multiple Gigabit Ethernet ports, which facilitate high-speed data transfer and enable seamless integration into existing network infrastructures. The device may also include 10 Gigabit SFP+ ports, providing the flexibility for high-capacity uplinks to support bandwidth-intensive applications and storage solutions.

Security is another focal point of the NEC N8406-022, with integrated features such as VLAN support, access control lists (ACLs), and port security measures. These capabilities protect sensitive data from unauthorized access and ensure that only legitimate users and devices can connect to the network.

Moreover, the N8406-022 often incorporates advanced energy-efficient technologies that minimize power consumption without compromising performance. This not only contributes to operational cost savings but also supports organizations in their sustainability efforts.

With its combination of performance, security, and energy efficiency, the NEC N8406-022 stands out as a reliable networking solution suitable for a wide range of enterprises looking to enhance their connectivity and operational efficiency. Whether deployed in data centers or as part of a corporate network, this device is built to meet the evolving demands of today’s digital landscape.